Standards:
UL 913 - 8th Edition, Revision Dec 6 2013
Markings:
CLASS I, DIV 1, GP ABCD, T4, Tamb = -50 ˚C to +75 ˚C, IP67
Europe
I1
ATEX Intrinsically Safe (IS)
Certificate:
Baseefa15ATEX0146X Issue 3
Standards:
EN IEC 60079-0:2018
EN 60079-11: 2012
Markings:
II 1 G, Ex ia IIC T4 Ga, Tamb = -50 ºC to +75 ºC, IP67
Specific conditons for safe use (X):
1. The plastic mounting foot may present a potential electrostatic
ignition risk and must not the rubbed or cleaned with a dry cloth.
2. When fitted with the appropriate high-temperature mounting foot,
the equipment may be attached to process pipework at a
temperature of up to 120 °C.
3. The enclosure may present a potential electrostatic ignition hazard
and must not be rubbed or cleaned with a dry cloth.
International
I7
IECEx Intrinsically Safe (IS)
Certificate:
BAS 15.0098X Issue 5
Standards:
IEC 60079-0:2017 Edition 7.0, IEC 60079-11: 2011 Edition 6.0
Markings:
Ex ia IIC T4 Ga, Tamb = -50 ºC to +75 ºC, IP67
Specific conditions for safe use (X):
1. The plastic mounting foot may present a potential electrostatic
ignition risk and must not the rubbed or cleaned with a dry cloth.
2. When fitted with the appropriate high-temperature mounting foot,
the equipment may be attached to process pipework at a
temperature of up to 120 °C.
3. The enclosure may present a potential electrostatic ignition hazard
and must not be rubbed or cleaned with a dry cloth.
Quick Start Guide
June 2019
16
Emerson.com/RosemountEmerson.com/Rosemount
Содержание Rosemount ET210
Страница 1: ...Quick Start Guide 00825 0100 4211 Rev AA June 2019 Rosemount ET210 Wireless Corrosion Transmitter ...
Страница 4: ...Quick Start Guide June 2019 4 Emerson com RosemountEmerson com Rosemount ...
Страница 18: ...6 8 China RoHS Quick Start Guide June 2019 18 Emerson com RosemountEmerson com Rosemount ...
Страница 19: ...June 2019 Quick Start Guide Quick Start Guide 19 ...