Emerson Rosemount 8712C Скачать руководство пользователя страница 2

Manual Supplement

00809-0200-4661, Rev AA

April 2004

Rosemount 8712D

S-2

AC POWERED UNITS

This procedure describes how to upgrade an 8712C AC powered transmitter 
to the 8712D AC powered electronics.

1. Disconnect power on the transmitter.

2. Remove 8712C Electronics (main board) from transmitter housing.

3. Remove 8712C line transformer and wiring harness from transmitter 

housing.

4. Install 08712-0529-0002 wiring harness.

5. Install AC powered 8712D electronics (8712-0822-0001).

NOTE

Only use AC power with 8712-0822-0001 electronics.

Table 1-1.  8712-0833-0001 Kit 
Contents

Item Number

Quantity

Description

C119980504-0104

1

SCREW, PHM ZNC PLTD, 8-32, 

1

/

4

, SLF LKG, TP 1

C091400022

1

FUSE 250V, 1A, QUICK, AGC 1

08712-0667-0111

1

LABEL, WIRING 8712D, AC TERMAL PRINTED

08712-0822-0001

1

CKT CD ASSY 8712D (AC PWR)

C103680031

1

WASHER, METAL LOCK, INT, NO8

C099830007

4

STANDOFF HEX, M-F, SST, 6-32X

1

/

4

, X

7

/

8

08712-0529-0002

1

WIRING ASSY 8712D ELECTRONICS, LOCK

08712-0823-0001

1

SHIELD PLASTIC, SNAP-FIT, ABS, BLACK

08712-0571-0004

1

LABEL WARNING, WIRING COMPARTMENT

Содержание Rosemount 8712C

Страница 1: ...boards work with existing LOI s with no modification From a service standpoint there are two changes to be aware of The 8712D requires a new DD This DD has been distributed to Service The TDS 00816 0100 4661 includes directions to determine if the existing 275 DD s need to be upgraded The 8712D boards come in two versions AC 8712 0822 0001 and DC 8712 0822 0010 powered This eliminates the separate...

Страница 2: ...5 Install AC powered 8712D electronics 8712 0822 0001 NOTE Only use AC power with 8712 0822 0001 electronics Table 1 1 8712 0833 0001 Kit Contents Item Number Quantity Description C119980504 0104 1 SCREW PHM ZNC PLTD 8 32 1 4 SLF LKG TP 1 C091400022 1 FUSE 250V 1A QUICK AGC 1 08712 0667 0111 1 LABEL WIRING 8712D AC TERMAL PRINTED 08712 0822 0001 1 CKT CD ASSY 8712D AC PWR C103680031 1 WASHER METAL...

Страница 3: ...ered Transmitter Figure 1 3 8712D AC Powered Transmitter 8712 06A EPS 8712C Electronics White Black Terminal Block Assembly Green 8712C Transformer Wiring 8712C Transformer New Wiring Harness 8712 0529 0002 8712 07A EPS AC 8712D Electronics 8712 0822 0001 White Black Green Terminal Block Assembly ...

Страница 4: ...200 4661 Rev AA April 2004 Rosemount 8712D Emerson Process Management Flow Groeneveldselaan 6 8 3903 AZ Veenendaal The Netherlands T 31 0 318 549 549 F 31 0 318 549 559 T 0800 966 180 U K only F 0800 966 181 U K only Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T 65 6777 8211 F 65 6777 0947 AP RMT Specialist emersonprocess com Emerson Process Managemen...

Отзывы: