Table A-26: Rosemount 5301 and 5302 Level and/or Interface in Liquids Ordering Information
(continued)
Consolidate to chamber (see
Consolidate to Chamber
Engineered solutions (see
Rxxxx
Engineered Solutions beyond standard model codes. (Consult factory for details)
Example model string: 5301-H-A-1-S-1-V-1A-M-002-05-AA-I1-M1C1
E-002-05, means 2 ft. and 5 in. probe length. M-002-05, means 2.05 m.
(1)
Not available with explosion-proof, flameproof, or type n approvals.
(2)
Process seal rating. Final rating depends on flange and O-ring selection. See “Temperature and pressure limits” on
Process temperature and pressure rating
,
(3)
Requires option None for sealing (no O-ring).
(4)
For other materials, consult the factory.
(5)
Requires Operating Temperature and Pressure code H, P, or C.
(6)
Only available for Probe Type code 3C.
(7)
Consult factory.
(8)
Only available with Operating Temperature and Pressure code S.
(9)
Requires firmware version 2.L3 or later.
(10)
Only available with Operating Temperature and Pressure code H.
(11)
0.79 lb (0.36 kg) standard weight for flexible single lead probe. L=5.5 in. (140 mm). For PTFE covered probes: 2.2 lb (1
kg) standard weight for flexible single lead probe. L=17.1 in. (434 mm).
(12)
Maximum probe length for Duplex 2205 probes is 105 ft (32 m).
(13)
Extra length for fastening is added in factory.
(14)
Requires model 5301.
(15)
Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending
on selected probe length unit. If tank height is unknown, please round up to an even length when ordering. Probes can
be cut to exact length in field. Maximum allowable length is determined by process conditions. See
for more probe length guidance.
(16)
Probes are intrinsically safe.
(17)
Requires F
OUNDATION
Fieldbus signal output (U
i
(18)
G
½
in. SST cable gland is included in delivery.
(19)
Available for tank connection with flange.
(20)
The standard alarm setting is high.
(21)
Weldings in accordance with EN/ISO standards.
(22)
Certificate includes all pressure retaining wetted parts.
(23)
Design and manufacturing according to ASME B31.1. No code stamp available. Welding in accordance with ASME IX.
(24)
Only available with Material of construction code 1, Operating temperature and pressure code S, H, or P, Probe type 3A,
3B, 3V, 4U, 4A, 4B, 4S, 5A, or 5B, together with ASME flanges size 2-in, 3-in, or 4-in.
(25)
Only available with Signal output code H and Probe type code 3V or 4U.
(26)
Suitable for use as a level sensor part of a limiting device, in accordance with EN 12952-11 and EN 12953-9.
(27)
For Probe Type 3A, 3B, 3C, 4A, 4B, 4S, and 4U, and PTFE-coated 5A.
(28)
Transmitters with aluminum housing are not approved for open deck installations.
(29)
Only for Operating Temperature and Pressure code S.
(30)
Not available with PTFE covered probes.
(31)
Consider any temperature limitations dependent on Material of construction, Hazardous locations certifications,
and/or O-ring selection.
(32)
Option code BR5 together with option code QS or QT is pending, consult factory.
(33)
Option code BR5 together with Remote housing options (B1, B2, B3) or Verification reflector options (HL1, HL2, HL3) is
pending, consult factory.
(34)
Not available with option code U1.
Specifications and reference data
Reference Manual
April 2019
00809-0100-4530
336
Rosemount 5300 Level Transmitter
Содержание Rosemount 5300 Series
Страница 1: ...Reference Manual 00809 0100 4530 Rev FA April 2019 Rosemount 5300 Level Transmitter Guided Wave Radar ...
Страница 26: ...Transmitter overview Reference Manual April 2019 00809 0100 4530 26 Rosemount 5300 Level Transmitter ...
Страница 112: ...Electrical installation Reference Manual April 2019 00809 0100 4530 112 Rosemount 5300 Level Transmitter ...
Страница 158: ...Configuration Reference Manual April 2019 00809 0100 4530 158 Rosemount 5300 Level Transmitter ...
Страница 168: ...Operation Reference Manual April 2019 00809 0100 4530 168 Rosemount 5300 Level Transmitter ...
Страница 244: ...Service and troubleshooting Reference Manual April 2019 00809 0100 4530 244 Rosemount 5300 Level Transmitter ...
Страница 380: ...Product certifications Reference Manual April 2019 00809 0100 4530 380 Rosemount 5300 Level Transmitter ...
Страница 396: ...Configuration parameters Reference Manual April 2019 00809 0100 4530 396 Rosemount 5300 Level Transmitter ...
Страница 487: ...Reference Manual 00809 0100 4530 April 2019 Reference Manual 487 ...