2.2.5
Installing in a plastic tank
Follow these guidelines when installing the level transmitter in a plastic tank or in a metal
tank with a plastic lid.
D1: Minimum 5.91 in (150 mm)
R: Launching plate
•
The plastic lid must have a drill hole with a minimum diameter of 5.91 in (150 mm).
•
Use a metal flange plate or launching plate (R) that sufficiently covers the drill hole. For
more information, see
•
Ensure that the distance between the probe and the tank wall is at least 3.15 in (80
mm). Adhere to the installation instructions in
. If necessary,
perform a tank adjustment.
CAUTION
When installed in plastic tanks, there may be deterioration caused by electromagnetic
interference from other devices. Follow these guidelines to avoid deterioration:
•
Apply a metal foil to the outside of the tank.
•
Apply a shielding screen between the level transmitter and other electronic units.
•
Install in a metal pipe only if hygienic requirements are met. For more information, see
.
2.2.6
Installing with 3-A
®
standards
The level transmitter is authorized to display the 3-A symbol. Follow these guidelines to
ensure 3-A compliance when installing the level transmitter.
•
Ensure that the transmitter is installed according to 3-A standards.
•
Use the level transmitter only with 3-A certified adapters marked with the 3-A symbol.
•
The process connection must have a self-draining leakage port. 3-A certified adapters
all have self-draining leakage ports.
•
Choose an installation position where the probe and process connection can be
cleaned with a spray ball.
Quick Start Guide
Installation
00825-0100-4326
January 2019
Quick Start Guide
21
Содержание Rosemount 326L
Страница 1: ...Quick Start Guide 00825 0100 4326 Rev 01 January 2019 Rosemount 326L Level Transmitter ...
Страница 2: ...2 ...
Страница 4: ...Contents Quick Start Guide January 2019 00825 0100 4326 4 Quick Start Guide ...
Страница 12: ...Introduction Quick Start Guide January 2019 00825 0100 4326 12 Quick Start Guide ...
Страница 24: ...Installation Quick Start Guide January 2019 00825 0100 4326 24 Quick Start Guide ...
Страница 42: ...Operation Quick Start Guide January 2019 00825 0100 4326 42 Quick Start Guide ...
Страница 46: ...Troubleshooting and maintenance Quick Start Guide January 2019 00825 0100 4326 46 Quick Start Guide ...
Страница 48: ...Setting ranges Quick Start Guide January 2019 00825 0100 4326 48 Quick Start Guide ...
Страница 50: ...Product certifications Quick Start Guide January 2019 00825 0100 4326 50 Quick Start Guide ...