![Emerson Rosemount 3101 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/emerson/rosemount-3101/rosemount-3101_reference-manual_104699048.webp)
36
Reference Manual
00809-0100-4840, Rev CB
February 2015
To change the duty
1.
Press the green button
to enter the menu system from the PV display (see the note
above.) The display indicates “dutY”.
2.
Press the blue button
to enter the “dutY” menu and display the presently selected
duty: “LEVEL”, “Flo”, “cont”, or “diSt”.
3.
If the duty is correct, press the red button
and then the green button
to get to the
next menu option. Otherwise, continue with step (
4.
Press the blue button
to start the editing mode. The duty flashes to indicate it may
now be edited.
5.
Press the green button
repeatedly to scroll through the list of duties.
6.
Press the blue button
to confirm the duty. The flashing then stops.
7.
Press the red button
to save if the new duty is correct, or press the blue button
to
not save. Afterwards, depending on the button pressed, either the “dutY” menu or the
next menu appears.
Note
This menu option is in the programming menu. See
for a map of the
menu structure and how to access the menu options.
4.4.3
Selecting the units of measurement (on the 3102/3105)
Screen display:
unitS
Default:
m (metric) or ft (Imperial)
Note
The factory default units of measurement are dictated by the model part number
(see
“Ordering information” on page 87
A metric unit can be re-configured to be an Imperial unit, or vice-versa, by changing the
transmitter base units. See
“Changing the base units (on the 3102/3105)” on page 74
Changing base units after programming the transmitter will cause all programmable
data to be overwritten with factory default values (which are shown at the beginning of
the sections that follow)
The transmitter is pre-programmed with selectable measurement units for each of the duties
available:
Distance and Level measurement:
m, ft, in, or none
Flow measurement:
l/s, l/m, m
3
/hr, gal/m, ft
3
/m (cfm), ft
3
/hr, m ga (MGD), or none
Contents measurement:
l, m
3
, gal, or ft
3
Содержание Rosemount 3101
Страница 2: ......
Страница 4: ...ii Reference Manual 00809 0100 4840 Rev CB Title Page February 2015 ...
Страница 12: ...x Reference Manual 00809 0100 4840 Rev CB Contents February 2015 Contents ...
Страница 34: ...22 Reference Manual 00809 0100 4840 Rev CB Section 3 Installation February 2015 Installation ...
Страница 68: ...56 Reference Manual 00809 0100 4840 Rev CB Section 4 Starting up February 2015 Starting up ...
Страница 112: ...100 Reference Manual 00809 0100 4840 Rev CB Appendix B Product Certifications February 2015 Product Certifications ...
Страница 120: ...108 Reference Manual 00809 0100 4840 Rev CB Appendix C Integrated Display Menus February 2015 Integrated Display Menus ...
Страница 128: ...116 Reference Manual 00809 0100 4840 Rev CB Appendix E Field Communicator Menus February 2015 Field Communicator Menus ...
Страница 236: ...224 Reference Manual 00809 0100 4840 Rev CB Index February 2015 Index ...
Страница 237: ......
Страница 238: ......
Страница 239: ......