![Emerson Rosemount 3101 Скачать руководство пользователя страница 161](http://html.mh-extra.com/html/emerson/rosemount-3101/rosemount-3101_reference-manual_104699161.webp)
149
Reference Manual
00809-0100-4840, Rev CB
Appendix F: Programming the 3102 and 3105 using HART
February 2015
Programming the 3102 and 3105 using HART
Tank Shape/NLP (P011) = “Horizontal Cyl Dome”
This Horizontal Cylinder With Domed Ends setting is applicable when volume measurements are
needed from a horizontally-oriented cylindrical tank with a constant diameter (see
for a cross-sectional view).
The volume is calculated from the live level measurement, the full volume of an ideal cylindrical
tank, and the diameter of that tank.
Setting-up Procedure for “Horizontal Cyl Dome”:
1.
Use the Tank Shape/NLP (P011) parameter to select “Horizontal Cyl Dome”.
2.
Enter the full volume into the PV Scale Factor parameter (
3.
Enter the tank diameter into the Profile Height / Power Factor parameter (
).
Содержание Rosemount 3101
Страница 2: ......
Страница 4: ...ii Reference Manual 00809 0100 4840 Rev CB Title Page February 2015 ...
Страница 12: ...x Reference Manual 00809 0100 4840 Rev CB Contents February 2015 Contents ...
Страница 34: ...22 Reference Manual 00809 0100 4840 Rev CB Section 3 Installation February 2015 Installation ...
Страница 68: ...56 Reference Manual 00809 0100 4840 Rev CB Section 4 Starting up February 2015 Starting up ...
Страница 112: ...100 Reference Manual 00809 0100 4840 Rev CB Appendix B Product Certifications February 2015 Product Certifications ...
Страница 120: ...108 Reference Manual 00809 0100 4840 Rev CB Appendix C Integrated Display Menus February 2015 Integrated Display Menus ...
Страница 128: ...116 Reference Manual 00809 0100 4840 Rev CB Appendix E Field Communicator Menus February 2015 Field Communicator Menus ...
Страница 236: ...224 Reference Manual 00809 0100 4840 Rev CB Index February 2015 Index ...
Страница 237: ......
Страница 238: ......
Страница 239: ......