A.6 Options
A.6.1 Standard configuration
Unless otherwise specified, transmitter is shipped as
follows:
A.6.2 Custom configuration
If Option Code C1 is ordered, the customer may specify the
following data in addition to the standard configuration
parameters.
Output Information
Transmitter Information
LCD display Configuration
Hardware Selectable Information
Signal Selection
Refer to the Rosemount 3051
.
A.6.3 Tagging (3 options available)
Standard SST hardware tag is permanently affixed on
transmitter. Tag character height is 0.125 in. (3,18 mm),
84 characters maximum.
Tag may be wired to the transmitter nameplate upon
request, 85 characters maximum.
For HART protocols, the tag may be stored in transmitter
memory (eight characters maximum). Software tag is left
blank unless specified.
–
HART Revision 5: 8 characters
–
HART Revision 7: 32 characters
Y2
Nameplates, Labels, Tags and Fasteners
316SST Nameplates, Labels, Tags and Fasteners
A.6.4 Optional Rosemount 306
integral manifolds
Factory assembled to Rosemount 3051P Transmitters.
Rosemount 306
for additional
information.
A.6.5 Other seals
for
additional information.
A.6.6 Output information
Output range points must be the same unit of measure.
Available units of measure include:
A.6.7 Display and interface options
M4
Digital Display with LOI
Available for 4-20 mA HART, 4-20 mA HART Low Power
M5
Digital Display
2-Line, 5-Digit LCD for 4-20 mA HART
2-Line, 5-Digit LCD for 1-5 Vdc HART Low Power
Direct reading of digital data for higher accuracy
Displays user-defined flow, level, volume, or pressure
units
Displays diagnostic messages for local troubleshooting
90-degree rotation capability for easy viewing
Engineering units
psi (all ranges)
4 mA
0 (engineering units)
20 mA
Upper range limit
Output
Linear
Flange type
Specified model code option
Flange material
Specified model code option
O-ring material
Specified model code option
Drain/vent
Specified model code option
LCD display
Installed or none
Alarm
High
Software tag
(Blank)
Pressure units
(1)
1. Field configurable only, not available for factory calibration or custom configura-
tion (option code C9 “Software configuration”).
torr
psf
cmH
2
atm
inH
2
O
mH
2
Pa
inH
2
O@4 °C
inHg
kPa
inH
2
mmHg
MPa
ftH
2
O
cmHG@0 °C
hPa
ftH
2
O@4 °C
mHG@0 °C
mbar
ftH
2
O@60 °F
g/cm
2
bar
mmH
2
O
kg/m
psi
mmH
2
kg/cm
2
Содержание Rosemount 3051P
Страница 2: ......
Страница 8: ...6 Reference Manual 00809 0700 4001 Rev AA Contents May 2017 Contents ...
Страница 12: ...2 Reference Manual 00809 0700 4001 Rev AA Introduction May 2017 Introduction ...
Страница 36: ...26 Reference Manual 00809 0700 4001 Rev AA Configuration May 2017 Configuration ...
Страница 66: ...56 Reference Manual 00809 0700 4001 Rev AA Operation and Maintenance May 2017 Operation and Maintenance ...
Страница 74: ...64 Reference Manual 00809 0700 4001 Rev AA Troubleshooting May 2017 Troubleshooting ...
Страница 98: ...Product Certifications May 2017 Reference Manual 00809 0700 4001 Rev AA Product Certifications 88 ...
Страница 109: ......