Essential Instructions

 

Read this page before proceeding

 

Rosemount designs, manufactures, and tests its products to meet many national and international 

standards. Because these instruments are sophisticated technical products, you must properly install, use, 

and maintain them to ensure they continue to operate within their normal specifications. The following 

instructions must be adhered to and integrated into your safety program when installing, using, and 

maintaining Rosemount products. Failure to follow the proper/ instructions may cause any one of the 

following situations to occur: Loss of life; personal injury; property damage; damage to this instrument; and 

warranty invalidation.

 

 

Read all instructions prior to installing, operating, and servicing the product. If this Instruction Manual is 

not the correct manual, telephone 1-800-654-7768 and the requested manual will be provided. Save this 

Instruction Manual for future reference.

 

 

If you do not understand any of the instructions, contact your Rosemount representative for clarification.

 

 

Follow all warnings, cautions, and instructions marked on and supplied with the product.

 

 

Inform and educate your personnel in the proper installation, operation, and maintenance of the product.

 

 

Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual 

and per applicable local and national codes, for example, ANSI B16.5. Connect all products to the proper 

electrical and pressure sources.

 

 

To ensure proper performance, qualified personnel should install, operate, and maintain the product.

 

 

When replacement parts are required, ensure that qualified people use replacement parts specified by 

Rosemount Analytical. Replacement of original components with those constructed from alternative 

materials will void any CSA, FM, and BASEEFA/CENELEC agency approvals that were applicable to the original 

device. Furthermore, replacement of original components with those constructed from alternative materials 

might change the pressure, temperature, and/or performance specifications from those of the original 

configuration. Ensure replacement parts are compatible with process requirements. Unauthorized parts and 

procedures can affect the product’s performance, place the safe operation of your process at risk, and may 

result in fire, electrical hazards, or improper operation.

 

 

Ensure that all equipment doors are closed and protective covers are in place, except when maintenance is 

being performed by qualified persons, to prevent electrical shock and personal injury.

 

 

DANGER

 

HAZARDOUS AREA INSTALLATION

 

Installations near flammable liquids or in hazardous area locations must be carefully evaluated by qualified 

on site safety personnel. This sensor is not Intrinsically Safe or Explosion Proof.

 

To secure and maintain an intrinsically safe installation, the certified safety barrier, transmitter, and sensor 

combination must be used. The installation system must comply with the governing approval agency (FM, 

CSA, BASEEFA/CENELEC, or ATEX) hazardous area classification requirements. Consult your analyzer/ 

transmitter instruction manual for details.

 

Replacement of original components with those constructed from alternative materials will void any CSA,

 

FM, and BASEEFA/CENELEC agency approvals that were applicable to the original device.

 

Proper installation, operation and servicing of this sensor in a Hazardous Area Installation is entirely the

 

responsibility of the user.

 

 

  

CAUTION: SENSOR/PROCESS APPLICATION COMPATIBILITY 

 

The wetted sensor materials may not be compatible with process com position and operating conditions. 

Replacement of original components with those constructed from alternative materials might change the 

pressure, temperature, and/or performance specifications from those of the original sensor configuration. 

Application compatibility is entirely the responsibility of the user.

 

Содержание Rosemount 245

Страница 1: ...Instruction Manual LIQ MAN 245 Rev E June 2017 RosemountTM 245 Toroidal Flow Through Conductivity Sensor ...

Страница 2: ... 04 This is the initial release of the product manual The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product offering B 1 08 Addition of section 1 7 on page 5 C 3 12 Update pages 12 and 16 D 01 14 The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product offering...

Страница 3: ...ovals that were applicable to the original device Furthermore replacement of original components with those constructed from alternative materials might change the pressure temperature and or performance specifications from those of the original configuration Ensure replacement parts are compatible with process requirements Unauthorized parts and procedures can affect the product s performance pla...

Страница 4: ......

Страница 5: ...nce Values for RTD 9 2 2 Sensor Wire Resistance Values with InstrumentCable Disconnect 9 List of Figures Sanitary Flow Through Toroidal Conductivity Sensor 2 245 Junction Box withRTD Diagram 4 Sensor to Junction Box Wiring 5 Extension Cable 6 Wiring Extension Cable to 54ec 6 Wiring Extension cable to 1056 and 56 6 Wiring Extension cable to Xmt T Panel Mount 6 Wiring Extension Cable to Xmt T Pipe W...

Страница 6: ...Table of Contents Instruction Manual June 2017 LIQ MAN 245 This page left blank intentionally ...

Страница 7: ...e compliant with USP Class VI requirements The 245 sensor is easy to install It clamps into the process piping between two Tri Clamp flanges Installation of special grounding rings is not needed because contact rings are already built into the sensor A junction box to facilitate wiring is included Conductivity depends strongly on temperature and conductivity measurements are typically corrected to...

Страница 8: ...r supplies the mating flanges clamps gaskets and Pt 1000 RTD Model 245 Sanitary Flow Through Toroidal Conductivity Sensor CODE LINE SIZE Required Selection 01 02 1 03 1 04 2 CODE PROCESS CONNECTION Required Selection 12 Tri Clamp CODE CONTACT RING MATERIAL Required Selection SS 316L Stainless Steel CODE LINER MATERIAL Required Selection PK unfilled PEEK CODE PROCESS O RING MATERIAL Required Select...

Страница 9: ...1000 TCmounted in a separate thermowell is also acceptable 2 Thread the RTD wires into junction box Wire the RTD to the j box terminals as indicated in Figure 1 4 Use of optional kit PN 24086 00 is recommended Extension Cable Hook Up 1 Sensor cable should not be run in conduit or open trays with any A C power wiring nor routed near heavy electrical equipment 2 For best sensor instrument loop perfo...

Страница 10: ...dard as a function of temperature is known configure the analyzer to measure raw conductivity no temperature correction Also obtain a calibrated thermometer Place the thermometer in a beaker of water next to the sensor DO NOT PUT THE THERMOMETER IN THE SENSOR b If the conductivity of the standard is known only at 25 ºC leave the analyzer slope temperature correction on and set the temperature coef...

Страница 11: ... the external toroids during service It does not detect changes in the contact rings It is not a calibration 1 Empty and dry the sensor 2 Attach a resistance decade box to the two yellow wires See Figure 2 1 3 Configure the analyzer to measure raw conductivity no temperature compensation 4 Adjust the resistance until the analyzer display reads the same number it did during calibration Record the r...

Страница 12: ...uction Manual June 2017 LIQ MAN 245 Figure 1 4 Extension Cable Figure1 5 Wiring extension cable to 54ec Figure1 6 Wiring extension cable for 1056 and 56 Figure1 7 Wiring extension cable to Xmt T Panel Mount 6 245Sensor ...

Страница 13: ...SE RTD IN SHLD RCV A RSHLD DRV B DRV A DSHLD 1 8 Maintenance The only routine maintenance required during the operational life of the sensor is to ensure that there are no deposits plugging the sensor or coating the inside of the contact rings Some customers find it advantageous to periodically replace process Tri Clamp gaskets to ensure adequate process seals Rebuilding the sensor must be done at...

Страница 14: ...245 Sensor Instruction Manual June 2017 LIQ MAN 245 This page left blank intentionally 8 245Sensor ...

Страница 15: ... sensor for open connections and short circuits Be sure to disconnect the cable PN 23909 00 before checking See Table 2 2 and Figure 2 1 Table 2 1 Resistance Values for Pt 100 and Pt 1000 RTDs Temperature Resistance Ohms C F Pt 100 Pt 1000 18 64 4 106 9 1069 19 66 2 107 3 1073 20 68 0 107 7 1077 21 69 8 108 1 1081 22 71 6 108 4 1084 23 73 4 108 9 1089 24 75 2 109 2 1092 25 77 0 109 6 1096 26 78 8 ...

Страница 16: ...Section Title Instruction Manual June 2017 LIQ MAN 245 Figure 2 1 Sensor Circuit for Troubleshooting 10 Troubleshooting ...

Страница 17: ......

Страница 18: ...ectric Co Rosemountis a mark of one of the Emerson family of companies All other marks are the property of their respective owners The contents of this publication are presented forinformationpurposes only and while effort has beenmade to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their us...

Отзывы: