Emerson PENBERTHY K3 Series Скачать руководство пользователя страница 2

2

PENBERTHY 

SERIES K3 GAGECOCKS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

2 INTRODUCTION

2.1 Features and specifications

Penberthy Series K3 tubular glass gagecocks 
are supplied in pairs (upper and lower) 
and are designed to house each end of a 
transparent sight glass tube. This gagecock/
glass combination forms a gage that accurately 
indicates liquid level as well as liquid 
characteristics.
Standard features of K3 gagecocks in non 
steam-water applications are: a ball check 
shut-off to stop leakage of contained fluid in 
case of accidental gage glass breakage, integral 
bonnet, integral drain cock and handwheel.

Series K3 gagecocks are not suitable for 
steam-water applications unless they are 
furnished with one of the following optional 
features:
1.  Non-automatic gagecocks – ball checks 

removed from both upper and lower 
gagecocks.

2.  Automatic gagecocks – vertical ring ball 

check and ball inspection plug in the lower 
gagecock. The upper gagecock is equipped 
with a horizontal ball check and a leaky ball 
seat formed in the body.

CAUTION

Failure to follow any instruction could possibly 
result in a malfunction of the gagecock with 
resulting sudden release of pressure, property 
damage or physical injury.

Safety instructions

Emerson does not have any control over the 
manner in which its gagecock set is handled, 
installed, or used and Emerson cannot and does 
not warrant or guarantee that a gagecock set is 
suitable for or compatible with the user's specific 
application.

1 ABOUT THE MANUAL

This manual has been prepared as an aid and 
guide for personnel involved installation or 
maintenance. All instructions must be read and 
understood thoroughly before attempting any 
installation, operation or maintenance.

Safety instructions

Under most circumstances, Series K3 
gagecocks are not recommended without a 
ball check shut-off. Gagecocks without the ball 
check shut-off feature will not stop leakage of 
contained fluid in the event of accidental tubular 
glass breakage. However, in circumstances 
where the fluid being gaged tends to surge in a 
rapid manner, the ball checks could tend to give 
a false level reading or seat accidentally.

2.2 Design ratings at maximum and minimum 
operating temperatures (see Table 1)

To determine the maximum allowable working 
pressure for a specific temperature within the 
design limits stated below, the user should 
refer to relevant technical data sheets or, when 
provided, the specifically stated design limits on 
a product proposal.

CAUTION

Under no circumstances should K3 gagecocks be 
used for steam-water applications unless they are 
equipped with one of these optional features. Use 
of standard K3 gagecocks without these features 
may result in sudden release of pressure, leakage 
of contained fluid, property damage or physical 
injury.

TABLE 1 - DESIGN RATINGS

Material

Model

Maximum allowable working pressure

Maximum steam pressure

Bronze

K3A

225 psig [1.55 MPa] at -20°F [-29°C] to +100°F [38°C] 
150 psig [1.03 MPa] at 500°F [260°]

175psig [1.21 MPa]

K3B

500 psig [3.45 MPa] at -20°F [-29°C] to +100°F [38°C] 
300 psig [2.07 MPa] at 550°F [288°C]

360 psig [2.48 MPa]

Pressure/temperature ranges in above table are subject to the limitations of the tubular glass.
See Table 2.

2.3 Application data
Note:

 for specific application data, within the 

above ranges, the user should consult the 
product proposal for the specific model and 
size gagecock set or should request the supply 
of the applicable technical data sheet.

WARNING

Under no circumstances should these design 
ratings or application data be exceeded. 
Exceeding design ratings or application data may 
cause severe physical injury or property damage.

Содержание PENBERTHY K3 Series

Страница 1: ...y other cause or for consequential damages It is expressly understood that Emerson is not responsible for damage or injury caused to other products buildings personnel or property by reason of the installation or use of its products This is Emerson s sole warranty and in lieu of all other warranties expressed or implied which are hereby excluded including in particular all Warranties of merchantab...

Страница 2: ... maintenance Safety instructions Under most circumstances Series K3 gagecocks are not recommended without a ball check shut off Gagecocks without the ball check shut off feature will not stop leakage of contained fluid in the event of accidental tubular glass breakage However in circumstances where the fluid being gaged tends to surge in a rapid manner the ball checks could tend to give a false le...

Страница 3: ...th the contained fluid and the surrounding atmosphere in the specific application Safety instructions If the size model or performance data of the gagecock set as received does not conform with any of the criteria above do not proceed with installation Contact an authorized Penberthy distributor for direction 4 INSTALLATION Installation should only be undertaken by qualified personnel who are fami...

Страница 4: ...ance schedules safety manuals and inspection details for each specific installation of a gagecock set For purposes of maintenance on all installations the gagecocks should be evaluated regularly by the user for signs of 1 leakage around stem area 2 internal stem leaks 3 leakage around stuffing box connection 4 internal or external corrosion The user must determine an appropriate maintenance schedu...

Страница 5: ...nnection Check vertical alignment of gagecocks h Slide sight glass down into lower gagecock sight glass connection to a positive stop i Tighten glass packing nuts j Close both gagecocks by turning handwheel or lever clockwise until stem seats k Replace guard rods Refer to Section 5 for operation of gagecock when returned to service 8 DISPOSAL AT END OF USEFUL LIFE Penberthy gagecocks are used in a...

Страница 6: ...lass 2 36 Gland glass packing 2 37 Nut glass packing 1 48 Glass 1 Recommended maximum quantities should provide spare parts for 10 of the gagecocks in service PARTS LIST Ref Item 40 Rod 48 Glass 37 Nut glass packing 36 Gland glass packing 34 Packing glass 33 Star 14 Ball retainer 15 Ball 11 Body 17 Stem 20 Bonnet 21 Nut bonnet 18 Retainer stem packing 25 Packing stem 26 Nut stem packing 28 Handwhe...

Отзывы: