ak
Heavy Duty 460 VAC, 3-Phase Input and Output, 50/60 Hz Input
Heavy Duty
150% for 1 minute
Slim Enclosure
Cube Enclosure
Order Code
Dimensions
HxWxD (in)
Weight
(Ibs)
Order Code
Dimensions
HxWxD (in)
Weight
(Ibs)
HP
Amps
1
2.1
RSxxH4001xxx-x
38x16x16
135
RCxxH4001xxx-x
24x16x16
70
1.5
3
RSxxH41P5xxx-x
38x16x16
135
RCxxH41P5xxx-x
24x16x16
70
3
5.8
RSxxH4003xxx-x
38x16x16
135
RCxxH4003xxx-x
24x16x16
70
5
7.6
RSxxH4005xxx-x
38x16x16
135
RCxxH4005xxx-x
24x16x16
70
7.5
13
RSxxH47P5xxx-x
38x16x16
135
RCxxH47P5xxx-x
24x16x16
70
10
16.5
RSxxH4010xxx-x
38x16x16
140
RCxxH4010xxx-x
24x16x16
70
15
25
RSxxH4015xxx-x
38x16x16
140
RCxxH4015xxx-x
24x16x16
70
20
29
RSxxH4020xxx-x
38x16x16
140
RCxxH4020xxx-x
24x16x16
70
25
32
RSxxH4025xxx-x
56x16x16
140
RCxxH4025xxx-x
30x24x16
70
30
40
RSxxH4030xxx-x
56x16x16
210
RCxxH4030xxx-x
30x24x16
150
40
60
RSxxH4040xxx-x
72x21x16
210
RCxxH4040xxx-x
39x30x16
150
50
74
RSxxH4050xxx-x
72x21x16
300
RCxxH4050xxx-x
39x30x16
250
75
96
RSxxH4075xxx-x
72x21x16
300
RCxxH4075xxx-x
39x30x16
280
100
124
RSxxH4100xxx-x
72x36x18
550
n/a
125
156
RSxxH4125xxx-x
72x36x18
550
150
180
RSxxH4150xxx-x
90x36x20
700
AC RapidPaks are available with Commander SK, Commander GP20 and Unidrive SP
Definition - RapidPak AC Order Code Configurator
Item
Description
Enclosure Style
C = Cube enclosure
S = Slimline enclosure
Cube enclosure option allows only the circuit breaker, non-fused disconnect switch and door operator devices.
The Slimline enclosure allows all the options unless bypass is selected, then there is a limit of either an input or
output reactor.
Drive Type
SKN = SK Normal Duty, SKH = SK Heavy Duty,
CGN = GP20 Normal Duty, CGH = GP20 Heavy Duty,
SPN = SP Normal Duty, SPH = SP Heavy Duty,
Three drive models: Commander SK, Commander GP20 & Unidrive SP, AC drives with a Normal duty, current
overload rating of 110% for 60 seconds. Heavy duty, current overloads rating of 150% for 1 minute.
Voltage Rating
8=208 VAC, 2=230 VAC, 3=380 VAC, 4=460 VAC
AC Input line voltage, 3 hp, 50/60 Hz, equals AC output rating for motor.
HP Rating
Motor hp ratings are based on typical motor current ratings. Actual motor currents and the type of applications
should be reviewed before selecting drive size.
Door Mounted Operator Station
0 = Blank
1 = Stop PB, Start PB, Fault Light, Pot.
2 = # 1 & Jog PB, Fwd/Rev SS
3 = # 2 & Power On Light
4 = HOA SS, Pot, Power On, VFD Run, Fault Light
5 = HOA SS, Plus Bypass
The blank option defines that the devices are remote mounted. Selection #1 to #5 defines that the devices are
door mounted and wired to the drive terminals.
Input Power
0 = Main Lugs with Input Fusing
1 = Circuit breaker (CB)
2 = Non-fused disconnect (NFD)
0 = Input Main lugs for customer termination with input fusing standard.
1 = CB with through the door operator, Thermal-magnetic overload protection and main circuit disconnect.
Includes drive input semiconductor fuses.
2 = NFD with through the door operator, main circuit disconnect. Includes drive fusing.
Note: Weight does not include options.