background image

WARNING: 

To avoid fire, shock, and serious personal injury, follow these

instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock

service panel disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, secure-
ly fasten a warning device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the

fan. Always turn off the power to the ceiling fan before servicing.

4. Do not put anything into the fan blades while they are turning.

5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before

wiring, and do not operate fan without blades.

2. The installation is to be in accordance with the National Electrical Code,

ANSI/NFPA 70-1999 and Local Codes. Use the National Electrical Code if Local
Codes do not exist. The ceiling fan must be grounded as a precaution against
possible electrical shock. Electrical installation should be made or approved
by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably

supporting at least 50 pounds. Use only U.L. outlet boxes listed as
“Acceptable for Fan Support”, and use the mounting screws provided with the
outlet box. Most outlet boxes commonly used for support of light fixtures are
not acceptable for fan support and may need to be replaced. Consult a quali-
fied electrician if in doubt.

4. The downrod furnished with the fan provides the minimum recommended floor

to fan blade clearance for an 8 foot ceiling.

5. The fan must be mounted with the fan blades at least 7 feet from the floor to

prevent accidental contact with the fan blades.

6. Follow the recommended instructions for the proper method of wiring your

ceiling fan. If you do not know enough about electrical wiring, have your fan
installed by a licensed electrician.

NOTE:

This fan is suitable for use with solid-state speed controls.

WARNING: 

To reduce the risk of fire or electric shock, this fan should only be

used with fan speed control Model No. UL7067RC, manufactured by Rhine
Electric Co., Ltd.

WARNING:

This product is designed to use only those parts supplied with this

product and/or any accessories designated specifically for use with this product
by Emerson Electric Co. Substitution of parts or accessories not designated for
use with this product by Emerson Electric Co. could result in personal injury or
property damage.

WARNING: 

To reduce the risk of personal injury, do not bend the blade flange

when installing the blade flanges, balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.

!

WARNING

DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label.
You should record this data above and keep it in a safe place for future use.

2

3

Tools Needed for Assembly

One Phillips head screwdriver
One wire stripper
One stepladder
Six wire connectors (supplied)

Materials

Wiring, outlet box and box connectors
must be of type required by the local code.
The minimum wire would be a 3-conductor
(2-wire with ground) of the following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Unpacking Instructions

For your convenience, check-off boxes
are provided next to each step. As each
step is completed, place a check mark
in the box. This will insure that all steps
have been completed and will be help-
ful in finding your place should you be
interrupted.

Do not install or use fan if any part is
damaged or missing. Call Toll-Free:

1-800-654-3545

!

WARNING

This product is designed to use only
those parts supplied with this product
and/or any accessories designated
specifically for use with this product by
Emerson Electric Co. Substitution of
parts or accessories not designated for
use with this product by Emerson Electric
Co. could result in personal injury or
property damage.

!

WARNING

a. Fan motor and housing assembly
b. One ceiling cover
c. Once coupling cover
d. Five fan blades
e. Five blade flanges
f. One hanger bracket
g. One hanger ball/downrod assembly
h. One switch housing/light fitter assy.
i. One lower ring assembly (includes

four mounting screws)

j. One lower glass
k. One remote control transmitter
l. One  remote control receiver
m. One loose parts bag containing:

1. Two 1-1/4” threaded studs
2. Two knurled knobs
3. Two lockwashers
4. Six wire connectors
5. One hairpin clip
6. One clevis pin
7. Eleven 1/4-20 x 11mm pan head 

screws with lockwashers

8. Sixteen 10-24 x 9mm truss 

head screws

9. Sixteen fiber washers

10. Four 8-32 x 7mm pan head screws

NOTE: Place the parts from the loose
parts bags in a small container to keep
them from being lost. If any parts are
missing, contact your local retailer or
catalog outlet for replacement before
proceeding.

B

C

A

D

F

E

I

K

FAN/OFF

FOR/REV

LIGHT

DIMMER

HI

MED

LOW

®

L

M

G

H

J

1. Open styrofoam unit containing fan.

Remove top half of styrofoam unit.
Remove parts and check to see that
you have received the following parts:

NOTE: If you are uncertain of part
description, refer to exploded view
illustration.

Содержание OLYMPIA KF100AP00

Страница 1: ...0000 Form No BP7280 READ AND SAVE THESE INSTRUCTIONS KF100AP00 Antique Pewter with Natural Cherry Mahogany Blades OLYMPIA Ceiling Fan Owner s Manual Emerson Fans Designed by KF100OZ00 Olde Bronze with Teak Olde Bronze Blades Model Numbers ...

Страница 2: ...on Electric Co could result in personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this ...

Страница 3: ...MER push button turns the lights on and off and controls the light intensity The red indicator light will illuminate while any button is pressed indicating that the bat tery is good 4 5 BATTERY BATTERY CONNECTOR CODE SWITCH REMOTE CONTROL TRANSMITTER 4 3 2 1 ON CODE SWITCH 1 2 3 4 ON BATTERY COVER SWITCH LEVERS Setting Operating Frequency of Transmitter and Receiver Your remote control transmitter...

Страница 4: ...e fan wobble 6 The fan comes with blue black and white leads that are 80 long Before installing the fan measure up approxi mately 6 to 9 inches above top of hang er ball downrod assembly Cut off excess leads and strip back insulation 1 2 from end of leads 7 Mount the fan blades to the blade flanges using three 10 24 x 9mm truss head screws and three fiber washers supplied Figure 6 3 Tighten the se...

Страница 5: ... must be properly grounded as a precaution against possible electrical shock WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire con nectors except for the ground wire Do not operate fan until blades are in place Noise ...

Страница 6: ...e airflow direction of the fan blades press the FOR REV button The direction the fan blades turn will change each time the FOR REV button is pressed 5 To set the level of light brightness press and hold the LIGHT DIMMER button The light brightness will contin ue to increase then decrease while the button is held down When the light is at the desired brightness release the button 6 To turn the ligh...

Страница 7: ...hock WARNING The use of any other control not specifically approved for this fan could result in fire shock and per sonal injury WARNING This product is designed to use only those parts supplied with this prod uct and or any accessories designat ed specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson ...

Страница 8: ...684 19 Housing Switch 762674 AP 762674 OZ 20 Fitter Assembly Light 762676 AP 762676 OZ 21 Glass Lower 762675 762675 1 22 Bracket Lower Ring 762678 AP 762678 OZ 23 Screw Mounting Bracket 8 762681 AP 762681 OZ 24 Ring Assembly Lower 762679 AP 762679 OZ 25 Receiver Remote Control 762670 762670 26 Transmitter Remote Control 762023 762023 Owner s Manual BP7280 BP7280 14 15 Repair Parts Repair Parts Lis...

Страница 9: ...center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also...