background image

11

1. Position the supply wires to the left side

of the outlet box (Figure 14); position
the fan wires to the right side. Partially
insert the remote control receiver (flat
side up) until one end rests on the
hanger ball as shown in Figure 14.

NOTE: Make all wiring connections
using wire connectors (supplied). Make
sure that all connections are tight,
including ground, and that no bare wire
is visible at the wire connectors, except
for the ground wire.
2. 
Refer to Figures 14 and 15 and connect

the receiver wires to the supply wires
and the fan motor wires as follows:

a. Securely connect the green grounding

wires from the hanger ball and the
hanger bracket to the supply grounding
conductor (this may be a bare wire or a
wire with green insulation).

Check to see that all connections are
tight, including ground, and that no
bare wire is visible at the wire
connectors, except for the ground
wire. Do not operate fan until blades
are in place. Noise and fan damage
could result.

!

WARNING

b. Securely connect the supply white

(neutral) wire to the receiver white
(AC IN N) wire.

c. Securely connect the supply black wire

(hot) wire to the receiver black (AC IN
L) wire.

d. Securely connect the fan motor white

wire to the receiver white (TO MOTOR
N) wire.

e. Securely connect the fan motor black

wire to the receiver red (TO MOTOR L)
wire.

f. Securely connect the fan motor blue

wire to the receiver blue (FOR
LIGHT) wire.

GREEN GROUND 
WIRE FROM 
HANGER BRACKET

RECEIVER RED WIRE

RECEIVER WHITE WIRE

FAN WHITE WIRE

FAN 
BLACK 
WIRE

ANTENNA

AC IN N

AC IN L

FOR LIGHT

T

O

 MOT

OR N

RECEIVER BLUE 
WIRE

RECEIVER 
BLACK WIRE

RECEIVER WHITE 
WIRE

SUPPLY WHITE WIRE 
(NEUTRAL)

SUPPLY BLACK 
WIRE (HOT)

GROUND WIRE

GREEN GROUND 
WIRE FROM 
HANGER BALL

FAN BLUE WIRE

1-1/4" THREADED 
STUD (2)

T

O

 MOT

OR L

Figure 14

BP7306 Nottingham  6/19/06  1:00 PM  Page 11

Содержание NOTTINGHAM CF4600GLZ00

Страница 1: ...horized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson El...

Страница 2: ...r support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling This fan should NOT be mounted on an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accid...

Страница 3: ...ize A W G Up to 50 ft 14 50 100 ft 12 Before assembling your ceiling fan refer to section on proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the...

Страница 4: ...an to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse or circuit breaker box at this tim...

Страница 5: ...must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING IMPORTANT Before assembling your ceiling fan refer to sections Setting Operating Frequency of Wall Control and Receiver and Installation of Wall Control page 13 These sections instruct you how to a Set the operating frequency of the fan light w...

Страница 6: ...ng the screws be sure there are no wires pinched between the switch cup adapter and switch cup assembly 6 5 32 x 9 16 PAN HEAD SCREWS 2 MOUNTING HUB BLADE FLANGE Figure 2 SWITCH CUP ASSEMBLY CONNECTORS REMOVE AND RETAIN FOUR PAN HEAD SCREWS SWITCH CUP ADAPTER Figure 3 SWITCH CUP ASSEMBLY REINSTALL FOUR PAN HEAD SCREWS Figure 4 6 Carefully place the partially assembled ceiling fan on the lower styr...

Страница 7: ... to make sure the clevis pin is properly installed WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 6 could result in the fan falling 10 Install the 5 16 18 x 1 4 setscrew supplied in the motor coupling Figure 6 While pulling up on the down...

Страница 8: ...n the lower housing flange Figure 9 After the glass is properly seated tighten the setscrew in the upper housing CAUTION Be sure there are no wires pinched between the glass and the lower housing flange 8 DOWNROD SETSCREW UPPER HOUSING GLASS LOWER HOUSING FLANGE Figure 9 LOCKWASHER 2 KNURLED KNOB 2 COUPLING COVER 7 WATT MAXIMUM CANDELABRA BULB 6 MOTOR COUPLING SOCKET 1 THREADED STUD 2 Figure 7 UPP...

Страница 9: ...with hanging and wiring your fan How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 11 Do NOT hang this fan on an 8 ceiling a 9 ceiling is required to maintain the 7 clearance WARNING CEILING AT LEAST 7 FLOOR 19 Reinstall the hanger ball on the downrod Figure 10 as follows Route the motor leads through the hanger ball and slide the hanger bal...

Страница 10: ...ng fan must be properly grounded as a precaution against possible electrical shock WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified elect...

Страница 11: ...d and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING b Securely connect the supply white neutral wire to the receiver white AC IN N wire c Securely connect the supply black wire hot wire to the receiver black AC IN L wire d Securely connect the fan motor white wire to the receiver...

Страница 12: ...igure 16 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling CEILING COVER LOCKWASHER 2 KNURLED KNOB 2 1 1 4 THREADED STUD 2 12 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING Figure 16 7 Your ceiling fan is now installed and wired and re...

Страница 13: ...on of Wall Control SINGLE POLE INSTALLATION Figure 18 1 Disconnect power at circuit breaker or remove fuse 2 Remove faceplate and screws from existing wall control Pull control out from the wall box Determine the hot wire and the load wire and disconnect these wires from control Do not attempt to disconnect any wires not already connected to existing control 3 Before installing wall control place ...

Страница 14: ...onnect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied NOTE Retrofit 3 way installations are likely to include two traveler wires between the two wall boxes In new construction only one traveler wire Is required 3 WAY WIRlNG DIAGRAM NEW CONSTRUCTION 6 Place wall control into wall box Screw in place and install decorator st...

Страница 15: ...n the ON position 2 To set the desired fan speed press the HI MED or LOW buttons to operate your fan on high medium or low speed Figure 22 3 To turn your fan off press the OFF button 4 To set the level of housing light brightness press and hold the LIGHT button The light brightness will continue to increase then decrease while the button is held down When the light is at the desired brightness rel...

Страница 16: ...ply circuit before installing the fan and optional light kit and or remote control receiver To install an optional Emerson light kit remove the four screws securing the switch cup assembly to the switch cup adapter Remove the finial nut from the switch cup and install the light kit in accordance with the light kit Owner s Manual To avoid possible electrical shock be sure electricity is turned off ...

Страница 17: ...radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna In...

Страница 18: ...packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 18 BP7306 Nottingham 6 19 06 1 00 PM Page 18 ...

Страница 19: ...7 Cover Ceiling 762972 GLZ 762972 WB 18 Cover Upper 762973 GLZ 762973 WB 19 Trim Housing 762977 GLZ 762977 WB 20 Glass Upper 762975 762975 21 Flange Set full set for one fan 762980 GLZ 762980 WB 22 Blade Set full set for one fan 762985 762985 23 Cup Assembly Switch 762988 GLZ 762988 WB 24 Nut Finial 762989 GLZ 762989 WB 25 Harness Assembly Housing Lights 762992 762992 26 Harness Assembly Reversing...

Страница 20: ...g screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling 1 Raise upper housing glass and excessively is not tightened securely coupling cover then tighten setscrew securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blade 3 Check to be sure screws flanges to mounting hu...

Отзывы: