Emerson MoistAIR HD1405 Скачать руководство пользователя страница 5

5

WARNING

For your own safety, do not

use humidifier if any parts are damaged
or missing.

Step 1

Place humidifier on a flat level surface in area
of house where humidity is needed most, or
one which would likely result in moist air
being circulated throughout the house such
as near a cold air return. Placing the unit
level is very important if the humidifier is
located on carpeting.

NOTE: This console humidifier contains
water bottles. The weight of the bottles in
the front of the cabinet may sink the front
casters deeper in the carpet. This will
keep the water level forward in the cabi-
net. The water level float (located at the
rear of the cabinet) may not sense the
water and the fill light will be on and the
unit will not energize. If this happens, the
unit will need to be leveled in order for the
humidifier to be energized.

To level the humidifier on carpeted surfaces
place the included caster pads under the
front two casters of the humidifier only.
Moist air (humidity) produced will disperse
into the whole house, but area closest to unit
will have the highest humidity. If the unit is
positioned close to a window, condensation
may form on the window pane. If this is not
appropriate the unit should be repositioned in
another location.

Location Instructions

Water Fill

WARNING: To reduce the risk of shock,
always unplug humidifier before filling,
cleaning, or servicing.

WARNING: To reduce the risk of fire or
shock hazard, do not pour or spill water
into control or motor area. Close the
control cover. If controls get wet, let
them dry completely and have unit
checked by authorized service person-
nel before plugging in.

This humidifier is designed to be used with
the two water bottles that are located under
the pivoting lid. 

NOTE: 

Due to release of cool, moist air from

humidifier, it is best to direct air away from
home thermostat and hot air registers. It is
best to position humidifier next to an inside
wall. Hot air registers and cold air from out-
side walls can affect the efficiencies of the
controls. Unit should not be placed where
warm air from a hot air register blows directly
on unit.

Step 2

The humidifier should be positioned with the
back (cord exit side), at least 2 inches away
from the wall. Air needs to enter through lou-
vers in the back of the cabinet in order for the
humidifier to operate at peak efficiency.

Water
Bottles

Cabinet

Front of Humidifier

Fan Assembly

NOTE: If positioning on carpet, place

caster pads under front casters only 

to level (if necessary).

Front of Cabinet

Front Caster

Caster Pad

Carpet 
Surface

At Least
2" From Wall

Pivoting Lid
Removed for
Clarity

SP6551 manual - 71238  7/12/05  1:56 PM  Page 5

Содержание MoistAIR HD1405

Страница 1: ... Canada CAUTION READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION SAVE THIS OWNER S MANUAL FOR FUTURE REFERENCE Model No HD14050 HD1405 Evaporative Console Humidifier Owner s Manual SP6551 manual 71238 7 12 05 1 56 PM Page 1 ...

Страница 2: ...AL SAFETY INSTRUCTIONS 2 Limited Warranty All products covered by this Owner s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors which are warranted for two years This warranty does not apply to damage from accident misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipmen...

Страница 3: ...S Gallons 2 3 8 Gallons Each Capacity of Bottles Litres 9 Litres Each Sq Ft Coverage 2 900 Fan Speeds 3 Number of Filters 4 Pack HDC 12 or HDC12C Fill Light Indicator Yes Desired Humidity Indicator Yes Auto Humidistat Yes Auto Shut Off Yes Manual Dryout Yes See Page 7 Controls Rotary CUL Listed Yes Volts 120 A C Hertz 60 Amps 2 88 Watts 165 Based on an area with average insulation and an 8 foot ce...

Страница 4: ...midified Air is Then Released Through the Top Dry Air Enters Through the Rear CAUTION Keep your humidifier clean While humidifiers do not cause colds some studies suggest that dirty humidi fiers can cause cold like symptoms in some people To avoid this clean your humidifier weekly with cleaners specifi cally recommended for evaporative humidifiers Unpacking Assembly Your new Emerson humidifier is ...

Страница 5: ...tioned in another location Location Instructions Water Fill WARNING To reduce the risk of shock always unplug humidifier before filling cleaning or servicing WARNING To reduce the risk of fire or shock hazard do not pour or spill water into control or motor area Close the control cover If controls get wet let them dry completely and have unit checked by authorized service person nel before pluggin...

Страница 6: ...ten only Check for possible leaks by performing the following 1 Grasp bottle handle and hold the bottle upright over a sink 2 Press up on valve cap plunger for about one second to let out a little water 3 Release the plunger 4 Listen for air bubbles Look for leaks around Side Fill Cap 5 If you hear air bubbles or see leaks retighten Side Fill Cap and repeat steps 1 4 NOTE Repeat for other bottle I...

Страница 7: ...en more humidity is called for the fans will turn on and the light will go out Air Flow Control The unit is adjusted from OFF to high with a three speed rotary control The higher the air flow speed the more water is evaporated and released into the air Low speed is the quietest and is provided for conditions that may not require as high an evaporation rate Fill Light When the unit has a small amou...

Страница 8: ...difier at least 2 inches from any wall and away from any heat reg isters 2 Do not restrict airflow from entering or exit ing the humidifier 3 Use liquid EPA Registered Bacteriostat to retard bacteria growth that may cause odors and may be harmful to your health 4 Regular cleaning as instructed in Cleaning Your Humidifier section of this manual is recommended 5 Replace the evaporative wicking filte...

Страница 9: ...overings are not susceptible to water damage i e kitchen or bath areas 2 Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front center and rear center Lift off and set aside on a clean flat surface The filter assemblies are now accessible 3 Lift filter housings out of cabinet and place where you may work on them comfortably With a soft absorbent cloth remove any ...

Страница 10: ...e that spring tabs of filter hous ings are towards front of cabinet Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cabi net f Position fan assembly onto the cabinet Make sure the fan venturi lowest cylin der section below the fan is placed inside the filter housing g Replace water bottles h Close the pivoting lid on the fan assembly i ...

Страница 11: ...nter Lift off and set aside on a clean flat surface The filter housings are now accessible b Before removing the internal parts of the humidifier cabinet we recommend moving the humidifier to an area where floor cov erings are not susceptible to water dam age i e kitchen or bath area Lift the filter housing assemblies out of the cabinet and set to the side c Remove the water level float from the h...

Страница 12: ...allon of water Let solution stay 20 minutes swishing every few minutes Wet all surfaces normally exposed to water 2 Empty humidifier cabinet after 20 min utes Rinse with water until bleach smell is gone Allow unit to dry out completely 3 Water bottles should be cleaned in same manner End of Season Maintenance 1 Follow bi weekly maintenance instructions at end of humidification season 2 Remove and ...

Страница 13: ... continue to empty A small amount of water in cabinet and fill light is on REMEDY Check 120 volt power source Turn speed control clockwise Raise humidistat setting if desired Free float from obstruction Slide float retainer down to lowest position in slot at back of cabinet See diagram on page 11 Change to fresh filters The humidifier is designed so the right bottle empties first Continue to run u...

Страница 14: ... Parts Parts List for MoistAir Humidifier Model No HD14050 28 27 26 25 24 23 28 27 21 26 30 24 23 22 21 20 19 18 14 15 13 31 12 11 33 16 17 3 1 32 8 10 7 5 4 6 9 34 2 SP6551 manual 71238 7 12 05 1 56 PM Page 14 ...

Страница 15: ... 20 823726 Rail Kick 21 Screw Pan Hd Ty AB 10 x 3 4 22 828515 Caster Twin Wheel 23 823849 Support Filter Lower 24 HDC 12 or Filter Evaporative USA HDC12C Filter Evaporative Canada 25 828197 Support Upper Filter 26 828534 Support Motor 27 828115 1 Motor Includes mounting hardware 28 822406 1 Fan 30 828197 Support Upper Filter 31 824120 Cord w Plug 32 826367 Retainer Micro Switch 33 Screw Pan Hd Typ...

Страница 16: ...11 04 FOR TECHNICAL HELP CALL 800 654 3545 FROM USA OR 888 744 4687 FROM CANADA Please have complete model number Emerson Tool Company For more information about MoistAir humidifiers visit our website at www moistair com SP6551 manual 71238 7 12 05 1 56 PM Page 16 ...

Отзывы: