20
Appendix I - Part Numbers
Please note that the existence of a part number does not imply the availability of a unit.
1. Sensors and Sensors with Head Amplifiers
Fitting
0
Outside Fitting
2
Double Fitting
3
Inside Fitting
6
Inside Fitting M6
8
Sludge Pipe
9
Flange
Head Amplifier Type
P
Sensor Mounted
U
Adjacent Mounted
Approval
O
None
H
ATEX
L
Lloyds Register of Shipping
P
PTB
S
SEV
F
LCIE
Sensor Type
See Catalogue
Material
D
Stainless steel
Y
Epoxy resin
P
Polyether sulphone
J
Cryogenic Epoxy Resin
M
Monel
C
Hastelloy C
Sensor Connection
0
PVC Cable & Phono Plugs
1
PTFE Cable & Phono Plugs
4
PVC Cable & BNC Plugs
5
PTFE Cable & BNC Plugs
7
PVC Cable & Pins
8
PTFE Cable & Pins
9
Special Cable
M
Marine Head Amplifier
I
Industrial Head Amplifier
J
Junction Box
3 0 2 S D P 8 0 T
Note: Pre 1984 sensors have an M or an I in the third place to indicate Marine or Industrial head
amplifier.
2. Head Amplifiers
(Adjacent mounted)
Intrinsic Safety
3
Intrinsically Safe
Mounting
A
Standard acting
X
Reverse acting
Sensor Type
C
Single
Test Switch
T
Included
N
Omitted
Type
I
Industrial
Electronics
3
1 MHz Switched Gain
4
3.7 MHz Switched
Material
A
Aluminium Alloy
G
Gunmetal
S
Stainless Steel
P
Plastic
Industrial Only
}
M E P 3 A I / 3 C A N
Options
T
Test Switch