![Emerson MICRO MOTION T-SERIES Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/emerson/micro-motion-t-series/micro-motion-t-series_installation-manual_100957008.webp)
•
The minimum angle of inclination of the sensor depends on the process fitting. See
Figure 1-2
and
Table 1-3
.
•
For clean-in-place (CIP) applications, Micro Motion recommends using the
generally-accepted flow velocity of at least 1.5 m/s for cleaning the sensor.
•
If the process piping must be larger than the sensor, eccentric reducers may be used
to ensure full drainability. In this case, the process end connections for the piping
and sensor must be the same size. See
Figure 1-3
.
Note
As part of the cleaning process, skid-based systems may be purged with nitrogen at the end
of the cleaning cycle. When using eccentric reducers, it is possible to trap gas in the section of
process piping adjacent to the reducer. Sensor performance can be impacted by intermittent
flow of the captured gas in a liquid fluid stream.
•
The gap between the electronics housing and sensor body should be inspected
periodically. Manually clean this gap when necessary.
Sensor inclination
Figure 1-2:
B
A
A.
Angle of inclination
B.
Direction of gravity
Minimum angle of inclination
Table 1-3:
Model
Fitting
code
Description
Min. angle
T025F, T025T
621
1/2-inch Tri-clamp compatible sanitary clamp
47°
670
DN10 DIN 11851 sanitary coupling
47°
671
DN15 DIN 11851 sanitary coupling
47°
676
DN15 DIN 11864-1A sanitary coupling
47°
T050F, T050T
621
1/2-inch Tri-clamp compatible sanitary clamp
0°
671
DN15 DIN 11851 sanitary coupling
47°
676
DN15 DIN 11864-1A sanitary coupling
47°
T075F, T075T
622
3/4-inch Tri-clamp compatible sanitary clamp
0°
623
1-inch Tri-clamp compatible sanitary clamp
47°
Planning
4
Micro Motion T-Series
Содержание MICRO MOTION T-SERIES