6. Wrap the drain wires twice around the shield and cut off the excess drain wires.
A. Drain wires wrapped around shield
7. For foil (shielded cable) only:
Note
For braided (armored cable) skip this step and contine to the next step.
Option Description
NPT
gland
type
a. Slide the shielded heat shrink over the drain wires. Ensure that the
wires are completely covered.
b. Apply 250 °F (121.1 °C) heat to shrink the tubing. Do not burn the
cable.
c. Position the clamping insert so the interior end is flush with the
braid of the heat shrink.
A. Shielded heat shrink
B. After heat is applied
M20
gland
type
Trim 0.3 in (8 mm).
A. Trim
8. Assemble the gland by folding the shield or braid back over the clamping insert and
0.125 in (3 mm) past the O-ring.
A. Shield folded back
Transmitter power and I/O wiring
Installation Manual
February 2020
20002172
20