11.4
Piecewise linearization (PWL) for calibrating
gas meters
Piecewise linearization (PWL) can linearize the measurements of flow meters for greater
accuracy in order to measure gas over a wide range of flow rates. PWL does not apply when
measuring liquid flow. When better accuracy is required over the published gas
measurement specifications, an Emerson-approved independent gas laboratory can
calibrate gas up to 10 PWL adjustment points.
PWL configuration and calibration information is not available through HART.
For more information, see the white paper,
The Practical Application of Multi‐Point Piecewise
Linear Interpolation (PWL) and Other Developing Trends with Coriolis Meters for Natural Gas
Custody Transfer Applications
, available at
The PWL feature is available in ProLink III, so you can view the points that are stored and
capture them in the uploaded and downloaded configuration files.
11.5
Use the fuel consumption application
For detailed information about fuel consumption, see the
Micro Motion
®
Fuel Consumption
Application for Transmitters Installation and Operation Guide
.
Restriction
Fuel consumption process variables are available only over HART with HART 7 enabled (default). Fuel
consumption parameters cannot be configured with HART.
11.5.1
Fuel consumption overview
The Fuel consumption application is designed to support fuel efficiency and fuel
management projects and practices by providing accurate real-time fuel consumption
data.
•
Automatically calculates the fluid consumption between two Coriolis flow sensors,
typically for recirculating fuel consumption loops
•
Eliminates the need to program an external calculation system and minimizes
common inaccuracies related to time lag, sampling issues and cumulative errors
•
Uses a proprietary algorithm that adapts to the unique calibration of each pair of
Coriolis flow sensors
11.6
Zero the meter
Zeroing the meter establishes a baseline for process measurement by analyzing the
sensor's output when there is no flow through the sensor tubes.
Measurement support
Configuration and Use Manual
149
Содержание Micro Motion 2500
Страница 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 20: ...Configuration and commissioning 12 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 124: ...Complete the configuration 116 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 130: ...Set up the Weights Measures application 122 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 132: ...Operations maintenance and troubleshooting 124 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 140: ...Transmitter operation 132 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 216: ...Using ProLink III with the transmitter 208 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 226: ...Default values and ranges 218 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 237: ...NE 53 history Configuration and Use Manual 229 ...