background image

2

Safety Instructions

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a. Use this unit only in a manner intended by the

manufacturer.  If you have questions, contact the
manufacturer.

b. Before servicing or cleaning unit, switch power off

at service panel and lock service panel
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a warning device, such as a tag, to the
service panel.

WARNING

!

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned

off at the fuse box before wiring, and do not operate
fan without blades.

2. All wiring must be in accordance with the National

Electrical Code “ANSI/NFPA 70-2011” and Local
Electrical Codes. Use the National Electrical Code if
Local Codes do not exist. The ceiling fan must be
grounded as a precaution against possible electrical
shock. Electrical installation should be made or
approved by a licensed electrician.

3. The outlet box and joist must be securely mounted

and capable of reliably supporting at least 50 pounds.
Use only U.L. outlet boxes listed as “Acceptable for
Fan Support of 22.7kg. (50 lbs.) or less”, and use the
mounting screws provided with the outlet box. Most
outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if
in doubt.

4. The downrod furnished with the fan provides the

minimum recommended floor to fan blade clearance
for an 8 foot ceiling.

5. The fan must be mounted with the fan blades at least

7 feet from the floor to prevent accidental contact with
the fan blades.

6. Follow the recommended instructions for the proper

method of wiring your ceiling fan. If you do not know
enough about electrical wiring, have your fan installed
by a licensed electrician.

WARNING: 

To reduce the risk of electrical shock, this

fan must be installed with an isolating wall
control/switch.

NOTE:

This fan is suitable for use with solid-state speed

controls.

WARNING:

This product is designed to use only those

parts supplied with this product and/or any accessories
designated specifically for use this product by Emerson
Electric Co. Substitution of parts or accessories not
designated for use with this product by Emerson could
result in personal injury or property damage.

WARNING: 

To reduce the risk of personal injury, do not

bend the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.

NOTE:

All setscrews must be checked and re-tightened

where necessary before installation.

1. Read your owner’s manual carefully and keep it for

future reference.

2. Be careful of the fan and blades when cleaning,

painting, or working near the fan. Always turn off the
power to the ceiling fan before servicing.

3. Do not put anything into the fan blades while they are

turning.

4. Do not operate reversing switch until fan blades have

come to a complete stop.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record

this data above and keep it in a safe place for future use.

U.L. Model No.: CF2000

READ AND SAVE THESE INSTRUCTIONS

Содержание MAUI BAY CF2000AB02

Страница 1: ...Damp Location Ceiling Fan Owner s Manual Model Numbers CF2000AB02 Antique Brass CF2000AP02 Antique Pewter CF2000ORB02 Oil Rubbed Bronze Net Weight 26 0 Lbs 1 800 654 3545 www emersonfans com Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday ...

Страница 2: ...an blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shoc...

Страница 3: ... retailer or catalog outlet for replacement before proceeding NOTE Fan blades are ordered separately and are packaged in separate carton 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B G E F C D PACKAGE CONTENTS 1 8 7...

Страница 4: ...capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in ...

Страница 5: ...evis pin must go through the holes in the motor coupling and the holes in the downrod Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properl...

Страница 6: ...ide the hanger ball up the downrod aligning the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 9 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above the ball...

Страница 7: ...Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 6 WARNING 1 Securely attach the hanger bracket to the outlet box using t...

Страница 8: ... using wire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground...

Страница 9: ... in a clockwise sequence Failure to follow this procedure could result in fan wobble This completes the blade installation 4 Slip the pull chain through the bushing in the switch housing cover Position the switch housing cover on the switch housing and secure using two 8 32 x 3 8 screws supplied Figure 13 Secure the pendant supplied to the pull chain using the connector supplied Fan Blade Installa...

Страница 10: ...aning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Maintenance SPEED CONTROL PULL CHAIN SWITCH REVERSING SWITCH Figure 14 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the 4 pos...

Страница 11: ...ing excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade flanges loose to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor...

Страница 12: ...12 U L Model No CF2000 Repair Parts 7 1 2 14 15 3 18 16 17 19 25 10 26 28 5 4 23 29 6 13 18 9 8 22 21 17 12 20 27 30 11 24 31 ...

Страница 13: ...92 762392 762392 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 1 12 Pendant 1 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 4 18 Knob Knurled 4 19 Screw 10 32 x 5 8 11 20 Screw 8 32 x 3 8 2 21 Screw 10 32 x 3 8 21 22 Washer Flat 21 29 Setscrew Hex Socket 1 30 Stud Threaded 1 2 6 Ceiling Canopy 761620 AB 761620 AP 761620 ORB 7 Hub Rubber 760601 760601 760601 8 Blade ...

Страница 14: ...14 U L Model No CF2000 Notes ...

Страница 15: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Страница 16: ... Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP73230002 Form No BP7323 2 Revision 130605 U L Model No CF2000 Printed in China 06 13 ...

Отзывы: