Installation Drawings 45
Figure 26 Outline Drawing, 1+1 Paralleling Panelboard, Configuration “N,” Size “A”
I/APPL/NPOWER/D
RAWINGS/OUTLINES/1
+1
SPC/U3711008/(C)
6/
17
/0
3
U3711008
OUTLINE DRAWING
NPOWER
1+1
SYSTEM
PARALLELING
PANELBOARD
CONFIGURATION "N", SIZE "
A"
DATE
FILE NAME:
COLUMBUS,
OHIO
43229
1050
DEARBORN
DRIVE,
REV. NO.
DWG. NO.
M MIERSEN
REF. DWG.
CHK BY
DRAWN BY
FRONT VIEW WITH DOOR OPEN
PANELBOARD
ENDWALL
RIGHT
SIDE
VIEW
FRONT VIEW WITH DOOR CLOSED
AND ACCENT REMOVED
ONE-LINE
DIAGRAM
NOTES:
1. SIZE "A" SYSTEM PARALLELING
PANELBOARDS MEET
THE
APPLICABLE REQUIREMENTS OF UL AND CSA.
2. ALL WIRING IS TO BE IN ACCORDANCE WITH NATIONAL AND
LOCAL
ELECTRIC
CODES.
3. PANELBOARD EXTERIOR IS CODE GAUGE GALVANIZED STEEL. BOTH ENDWALLS ARE BLANK. ANSI 49 GRAY BAKED ENAMEL
FINISH.
LOCK
IS
FLUSH
MOUNTED.
4.
NEMA-1
PANELBOARD
CONSTRUCTED
FOR
WALL-MOUNTING
ONLY.
5. FRONT ACCESS ONLY REQUIRED PER NEC ARTICLE 110-16.
TOP OR BOTTOM CABLE ENTRY/EXIT.
6. COPPER BUSSING IS STANDARD.
7.
OVERCURRENT
PROTECTIVE
DEVICES
ARE
AUTOMATIC
MOLDED CASE CIRCUIT BREAKERS.
8. LUG SIZE RANGES ARE BASED ON COPPER CONDUCTORS. ALUMINUM AND
COPPER-CLAD
ALUMINUM
CONDUCTORS ARE
NOT RECOMM
ENDED.
9.
REFERENCE
COMMON
INFORMATION
DRAWING
#U3711007
FOR ADDITIONAL PANELBOARD DETAILS.
ONE-LINE
LEGEND
Содержание Liebert Npower 100-130 kVA
Страница 1: ...POWER PROTECTION INSTALLATION MANUAL 30 130 kVA 60 Hz Single Module Systems 1 1 Redundant Systems ...
Страница 4: ...DISCONTINUED PRODUCT ...
Страница 5: ...DISCONTINUED PRODUCT i Table of Contents ...
Страница 6: ...DISCONTINUED PRODUCT ...
Страница 7: ...DISCONTINUED PRODUCT iii List of Figures ...
Страница 8: ...DISCONTINUED PRODUCT ...
Страница 10: ...DISCONTINUED PRODUCT ...
Страница 12: ...DISCONTINUED PRODUCT 2 Installation Considerations 2 0 INSTALLATION CONSIDERATIONS ...
Страница 16: ...DISCONTINUED PRODUCT 6 Inspections 4 0 INSPECTIONS 4 1 External Inspections 4 2 Internal Inspections ...
Страница 20: ...DISCONTINUED PRODUCT 10 Battery Installation ...
Страница 21: ...DISCONTINUED PRODUCT Battery Installation 11 6 2 Matching Battery Cabinets ...
Страница 22: ...DISCONTINUED PRODUCT 12 Battery Installation 6 3 Non Standard Batteries ...
Страница 32: ...DISCONTINUED PRODUCT 22 Wiring Considerations 8 0 WIRING CONSIDERATIONS ...
Страница 33: ...DISCONTINUED PRODUCT Wiring Considerations 23 8 1 Power Wiring ...
Страница 34: ...DISCONTINUED PRODUCT 24 Wiring Considerations 8 2 Control Wiring ...
Страница 41: ...DISCONTINUED PRODUCT Installation Drawings 31 Figure 12 Outline Drawing 65 80 kVA UPS ...
Страница 42: ...DISCONTINUED PRODUCT 32 Installation Drawings Figure 13 Outline Drawing 100 130 kVA UPS ...
Страница 58: ...DISCONTINUED PRODUCT 48 Installation Drawings Figure 29 Outline Drawing Seismic Anchoring 30 50 kVA UPS ...
Страница 59: ...DISCONTINUED PRODUCT Installation Drawings 49 Figure 30 Outline Drawing Seismic Anchoring 65 80 kVA UPS ...
Страница 60: ...DISCONTINUED PRODUCT 50 Installation Drawings Figure 31 Outline Drawing Seismic Anchoring 100 130 kVA UPS ...
Страница 61: ...DISCONTINUED PRODUCT Installation Drawings 51 Figure 32 Outline Drawing Remote Battery Breaker 30 130 kVA ...
Страница 64: ...DISCONTINUED PRODUCT 54 Installation Drawings Figure 35 Outline Drawing Remote Alarm Status Panel ...
Страница 65: ...DISCONTINUED PRODUCT Installation Drawings 55 Figure 36 Outline Drawing LBS Control Panel ...
Страница 66: ...DISCONTINUED PRODUCT 56 Installation Drawings Figure 37 Outline Drawing LBS Alarm Status Contacts ...
Страница 67: ...DISCONTINUED PRODUCT Installation Drawings 57 Figure 38 Outline Drawing LBS Transformer Panel ...
Страница 70: ...DISCONTINUED PRODUCT 60 Installation Drawings Figure 41 Control Wiring 30 130 kVA UPS ...
Страница 73: ...DISCONTINUED PRODUCT Installation Drawings 63 Figure 44 Control Wiring Remote Alarm Status Panel Option ...
Страница 74: ...DISCONTINUED PRODUCT 64 Installation Drawings Figure 45 Control Wiring 2 or 3 Remote Alarm Status Panels ...
Страница 76: ...DISCONTINUED PRODUCT 66 Installation Drawings Figure 47 Control Wiring Site Scan Interface ...
Страница 77: ...DISCONTINUED PRODUCT Installation Drawings 67 Figure 48 Control Wiring Programmable Relay Board Option ...
Страница 78: ...DISCONTINUED PRODUCT 68 Installation Drawings Figure 49 Control Wiring Input Contact Isolator Board ...
Страница 79: ...DISCONTINUED PRODUCT Installation Drawings 69 Figure 50 Control Wiring NIC Option ...
Страница 80: ...DISCONTINUED PRODUCT 70 Installation Drawings Figure 51 Control Wiring Power Supply Option ...
Страница 81: ...DISCONTINUED PRODUCT Installation Drawings 71 Figure 52 Control Wiring Internal Modem Option ...
Страница 82: ...DISCONTINUED PRODUCT 72 Installation Drawings Figure 53 Control Wiring AS 400 Signal Cable Option ...
Страница 83: ...DISCONTINUED PRODUCT Installation Drawings 73 Figure 54 Control Wiring Open Wire Cable Adaptor Option ...
Страница 84: ...DISCONTINUED PRODUCT 74 Installation Drawings Figure 55 Control Connection Diagram 50 130 kVA ...
Страница 85: ...DISCONTINUED PRODUCT Installation Drawings 75 Figure 56 Control Connection Location Diagram 30 130 kVA UPS ...
Страница 86: ...DISCONTINUED PRODUCT 76 Installation Drawings Figure 57 Terminal Details 30 50 kVA UPS ...
Страница 87: ...DISCONTINUED PRODUCT Installation Drawings 77 Figure 58 Terminal Details 65 80 kVA UPS ...
Страница 88: ...DISCONTINUED PRODUCT 78 Installation Drawings Figure 59 Terminal Details 100 130 kVA UPS ...
Страница 89: ...DISCONTINUED PRODUCT Installation Drawings 79 Figure 60 Schematic Diagram Maintenance Bypass Interlock System ...
Страница 92: ...DISCONTINUED PRODUCT 82 Installation Drawings Figure 63 Wiring Diagram UPS with Single Battery Cabinet ...
Страница 98: ...DISCONTINUED PRODUCT 88 ...
Страница 99: ...DISCONTINUED PRODUCT ...