Accessory Components Enhance Availability

Maintenance Bypass
Cabinet

The Liebert Nfinity 
maintenance bypass 
cabinet provides complete 
“wrap around” protection, 
allowing the Liebert Nfinity UPS 
to be pulled from service without
interrupting power to the protected
loads. Controls include a manual
bypass transfer switch, UPS input
disconnect switch and a branch rated
output circuit breaker.

Extended Battery
Cabinet

The Liebert Nfinity
extended battery cabinet
is available when extra run
time is critical to your
protected loads. This unit
has 12 bays that accept up
to 12 standard Liebert
Nfinity intelligent battery modules,
allowing you to add battery capacity
as needs change. 

Configurable Output
Distribution

The Liebert Nfinity
configurable output
distribution option
provides the flexibility to easily
connect multiple loads with various
receptacle types and current ratings
to the Liebert Nfinity. Receptacles
range from 15A to 30A types and
include a branch rated circuit breaker
to protect each individual load. Select
a maximum frame size of 6, 8, or 10
distribution plates, as well as a choice
of 6, 12, or 25 feet of cabled conduit.

The Liebert Nfinity UPS incorporates extensive firmware that
provides a comprehensive range of controls and operating
information, as well as communications capabilities. 

User Interface Control Panel

The user interface is the main source of communication between the
Liebert Nfinity UPS and the user. It features an easy-to-read LCD display
and LED mimic diagram. The control panel informs the user of the
status of the UPS, including the power and battery modules, and allows
you to configure the system to fit specific needs or preferences. 

Communication Connections

Dry contacts and a serial communications
port are standard. The unit also includes four
Intellislot

®

ports for multiple user options

including:

SNMP/WEB card that allows the 
Liebert Nfinity to communicate with 
an Ethernet network.
MultiPort4 cards that enable up to 
four client computers to monitor 
UPS status.
Relay contact cards to provide contact 
closures for remote monitoring of alarm conditions.

The system also communicates to and monitors internal and 

extended battery cabinets.

Shutdown Monitoring Software

Liebert MultiLink

®

is the perfect complement to the Liebert Nfinity UPS

because it prevents unexpected server
shutdowns, protects data and minimizes
downtime. The software provides
unattended, orderly shutdown
for one computer or many,
and is especially effective
with large server farms.
Liebert MultiLink has
full event
management and
displays UPS
instrumentation 
on screen. 

Power Monitoring And Control Capabilities

Intellislot

®

Содержание Liebert Nfinity 12-20kVA

Страница 1: ...AC Power For Business Critical Continuity Liebert Nfinity A Powerful UPS Solution For Small To Medium Data Centers ...

Страница 2: ...ts shrink in size capacity and criticality are increasing Powering all of this equipment is no small task That s why Liebert has developed a power protection solution that can expand easily as your needs grow Putting It All Together The Liebert Nfinity UPS System The Liebert Nfinity power system is a scalable UPS utilizing fault tolerant technology in two scalable models 4 to 16 kVA and 12 to 20 k...

Страница 3: ...ct efficient design allows you to pack more power and battery capability into a much smaller sized unit so it takes up less of your valuable floor space Higher Availability And Flexibility Start With Higher Intelligence The Liebert Nfinity is a true on line double conversion UPS that delivers 100 power conditioning zero transfer time to battery no change in output voltage and better transient supp...

Страница 4: ...r needs Your Liebert Nfinity UPS can be ordered in dozens of different power and battery capacities and then upgraded at any later time as needs change Using an 8 Bay 16 kVA frame Liebert Nfinity provides capacities up to 16 kVA in a non redundant mode and up to 12 kVA in an N 1 redundant mode with an incredibly small footprint only 20 W x 28 D x 41 H The 12 bay 16 kVA frame provides capacities up...

Страница 5: ...Shipped as a complete fully tested system ready for final connection Hot swappable modules allow installation or replacement of power battery control and display modules without shutting down or compromising power to the load Redundant components at critical points of UPS operation Maintenance performed without shutdown Intelligent fault tolerant design enables the power battery and control module...

Страница 6: ...nsive range of controls and operating information as well as communications capabilities User Interface Control Panel The user interface is the main source of communication between the Liebert Nfinity UPS and the user It features an easy to read LCD display and LED mimic diagram The control panel informs the user of the status of the UPS including the power and battery modules and allows you to co...

Страница 7: ...work provides immediate two way radio access to our factory trained customer engineers through our wireless communication system Exclusive Guaranteed Four Hour Response Time We can guarantee a four hour response time from the time your call is received at our CRC until a Liebert Customer Engineer arrives on site Applicable in U S and Canada Distance limitations apply Preventive Maintenance Prevent...

Страница 8: ...rt and the Liebert logo are registered trademarks of the Liebert Corporation SL 23900 R03 07 Printed in USA Ensuring The High Availability Of Mission Critical Data And Applications Scalable 12 20 kVA Scalable 4 16 kVA Specifications General Environmental Units Unit Rating kVA 4 8 12 16 20 kW 2 8 5 6 8 4 11 2 14 Conducted and Radiated EMC Levels FCC Part 15 Class A Compliant Safety Standards UL 177...

Отзывы: