![Emerson Level-Trol 2500 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/emerson/level-trol-2500/level-trol-2500_instruction-manual_2400763005.webp)
Type 2500
Instruction Manual
Form 1013
December 2005
5
Figure 2. Guidelines for Use of Optional Heat Insulator Assembly
0
20
40
60
80
100
120
140
160
USE INSULATOR (CAUTION! IF AMBIENT DEWPOINT IS ABOVE
PROCESS TEMPERATURE, ICE FORMATION MAY CAUSE INSTRUMENT
MALFUNCTION AND REDUCE INSULATOR EFFECTIVENESS.)
0
10
20
−
18
−
10
30
40
50
60
70
71
593
500
400
300
200
100
−
40
0
400
800
1100
−
20
NO INSULATOR NECESSARY
AMBIENT TEMPERATURE (
_
C)
STANDARD CONTROLLER OR TRANSMITTER
AMBIENT TEMPERATURE (
_
F)
HEAT INSULATOR
REQUIRED
TOO
HOT
NOTE:
FOR APPLICATIONS BELOW
−
29
_
C (
−
20
_
F), BE SURE THE SENSOR MATERIALS
OF CONSTRUCTION ARE APPROPRIATE FOR THE SERVICE TEMPERATURE.
PROCESS
TEMPERA
TURE ( C)
_
PROCESS
TEMPERA
TURE ( F)
_
0
20
40
60
80
100
120
140
200
0
10
20
−
18
−
10
30
40
50
60
70
105
593
500
400
300
200
100
0
0
400
800
1100
−
20
NO INSULATOR NECESSARY
AMBIENT TEMPERATURE (
_
C)
HIGH-TEMPERATURE CONTROLLER OR TRANSMITTER
AMBIENT TEMPERATURE (
_
F)
HEAT INSULATOR
REQUIRED
TOO
HOT
PROCESS
TEMPERA
TURE ( C)
_
PROCESS
TEMPERA
TURE ( F)
_
180
160
80
90
USE INSULATOR (CAUTION! IF AMBIENT DEWPOINT IS ABOVE PROCESS
TEMPERATURE, ICE FORMATION MAY CAUSE INSTRUMENT MALFUNCTION
AND REDUCE INSULATOR EFFECTIVENESS.)
CV6190
−
E
B1413-3/IL
−
40
−
29
−
18
100
220
Table 4.
Displacer and Torque Tube Materials
Part
Standard Material
Other Materials
Displacer
304 Stainless Steel
316 Stainless Steel,
N10276, N04400,
Plastic, and Special
Alloys
Displacer Rod,
Driver Bearing,
Displacer Rod
Driver
316 Stainless Steel
N10276, N04400,
other Austenitic
Stainless Steels, and
Special Alloys
Torque Tube
N05500
(1)
316 Stainless Steels,
N06600, N10276
1. N05500 is not recommended for spring applications above
232
_
C (450
_
F). Contact your Emerson Process Management
sales office or application engineer if temperatures exceeding this
limit are required.
Installation
The 2500 and 2503 Series controller/transmitters
work in combination with 249 Series displacer-type
sensors. The factory attaches the
controller/transmitter to the sensor, unless it is
ordered separately.
If using natural gas as the pneumatic supply
medium, natural gas will be used in the pressure
connections of the unit to any connected equipment.
The unit will vent natural gas into the surrounding
atmosphere.
WARNING
Always wear protective clothing,
gloves, and eyewear when performing
any installation operations to avoid
personal injury.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
WARNING
Personal injury or property damage
may result from fire or explosion if
natural gas is used as the supply
medium and preventative measures
are not taken. Preventative measures
may include: Re-evaluating the
hazardous area classification,
ensuring adequate ventilation, and the
removal of any nearby ignition
sources.
Sensor Assembly
Table 2 lists sensors recommended for use with
controller/transmitters. Table 4 contains displacer
and torque tube materials. For sensor installation
and maintenance, refer to the appropriate sensor
instruction manual.
WARNING
When replacing the sensor assembly,
the displacer may retain process fluid
or pressure. Personal injury or
property damage may occur due to