1. Position the supply wires to the left side

of the outlet box (Figure 12); position
the fan wires to the right side. Partially
insert the remote control receiver (flat
side up) until one end rests on the
hanger ball as shown in Figure 12.

NOTE: Make all wiring connections
using wire connectors (supplied). Make
sure that all connections are tight,
including ground, and that no bare wire

How to Wire

Your Ceiling Fan

Turning off wall switch is not suffi-
cient. To avoid possible electrical
shock, be sure electricity is turned
off at the main fuse box before
wiring. All wiring must be in accor-
dance with National and Local codes
and the ceiling fan must be properly
grounded as a precaution against
possible electrical shock.

!

WARNING

Check to see that all connections are
tight, including ground, and that no
bare wire is visible at the wire con-
nectors, except for the ground wire.
Do not operate fan until blades are in
place. Noise and fan damage could
result.

!

WARNING

If you feel that you do not have enough
electrical wiring knowledge or experi-
ence, have your fan installed by a
licensed electrician.

is visible at the wire connectors, except
for the ground wire.
2. 
Refer to Figure 12 and 13 and connect

the receiver wires to the supply wires
and the fan motor wires as follows:

a. Securely connect the green grounding

wires from the hanger ball and the
hanger bracket to the supply grounding
conductor (this may be a bare wire or a
wire with green insulation).

b. Securely connect the supply white

(neutral) wire to the receiver white (AC
IN N) wire.

c. Securely connect the supply black wire

(hot) wire to the receiver black (AC IN
L) wire.

d. Securely connect the fan motor white

wire to the receiver white (TO MOTOR
N) wire.

e. Securely connect the fan motor black

wire to the receiver red (TO MOTOR L)
wire.

f. Securely connect the fan motor blue

wire to the receiver blue (FOR LIGHT)
wire.

GREEN GROUND 
WIRE FROM 
HANGER BRACKET

RECEIVER RED WIRE

RECEIVER WHITE WIRE

FAN WHITE WIRE

FAN 
BLACK 
WIRE

ANTENNA

AC IN N

AC IN L

FOR LIGHT

T

O

 MOT

OR N

RECEIVER BLUE 
WIRE

RECEIVER 
BLACK WIRE

RECEIVER WHITE 
WIRE

SUPPLY WHITE WIRE 
(NEUTRAL)

SUPPLY BLACK 
WIRE (HOT)

GROUND WIRE

GREEN GROUND 
WIRE FROM 
HANGER BALL

FAN BLUE WIRE

1-1/4" THREADED 
STUD (2)

T

O

 MOT

OR L

Figure 12

CAUTION: To reduce the risk of electri-
cal shock, disconnect the electrical
supply circuit before installing the fan,
light kit or receiver.

BP7284, Sturbrige, KF180  7/31/06  10:52 AM  Page 9

Содержание KF180

Страница 1: ...S KF180AP01 Antique Pewter with Natural Cherry Mahogany Blades KF180OZ01 Olde Bronze with Teak Natural Pine Blades KF180DBK01 Distressed Black with Distressed Black Natural Cherry Blades STURBRIDGE Ceiling Fan Owner s Manual Emerson Fans Designed by Model Numbers BP7284 Sturbrige KF180 7 31 06 10 52 AM Page 1 ...

Страница 2: ...let boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan...

Страница 3: ...ries not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING a Fan motor and housing assembly b One ceiling cover c One adapter light fitter assembly d Five fan blades e Five blade flanges f One hanger bracket g One hanger ball downrod assembly h One lower ring assembly with six ring screws attached i One lower glass j One remote c...

Страница 4: ...d into two sections The first section REMOTE CONTROL PROCEDURES describes how to install the 9 volt alka line battery not supplied in the remote control transmitter and how to set the operating frequency of the transmitter and receiver These instructions must be performed prior to the installation of the ceiling fan as described in the second section CEILING FAN PROCE DURES REMOTE CONTROL PROCEDUR...

Страница 5: ...tion against possible electri cal shock WARNING How to Assemble Your Ceiling Fan 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 2 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for rein stallation in step 5 2 Unscrew the two upper setscrews Figure 3 until they clear the inside of ...

Страница 6: ... the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING 6 The fan comes with...

Страница 7: ...x 11mm PAN HEAD SCREW WITH LOCKWASHER 2 BLADE FLANGE MOTOR HUB Figure 6 ADAPTER ASSEMBLY ADAPTER PLATE WHITE WIRES BLACK WIRES 8 32 x 12mm PAN HEAD SCREW 2 Figure 7 ADAPTER LIGHT FITTER ASSEMBLY TIGHTEN TWO SCREWS INSTALL ONE 8 32 x 12mm PAN HEAD SCREW Figure 8 11 Connect the white wire from the light fitter to the white wire from the motor Figure 7 Connect the black wire from the light fitter to ...

Страница 8: ... for fan support and may need to be replaced Consult a qualified electri cian if in doubt WARNING CEILING AT LEAST 7 FLOOR Figure 9 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet bo...

Страница 9: ...e wire connectors except for the ground wire 2 Refer to Figure 12 and 13 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiv...

Страница 10: ...FROM HANGER BALL AND HANGER BRACKET TWO CONDUCTOR CABLE WITH GROUND BLACK HOT WHITE GROUND TO 120 VOLT SUPPLY WHITE BLUE WHITE BLUE Figure 13 3 Push the wires and connectors up into the outlet box while inserting the receiv er fully into the hanger bracket Position the antenna wire on top of the receiver 4 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figu...

Страница 11: ...Y RING SCREWS 6 RING ROD ARM Figure 16 Operating Your Ceiling Fan IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control Figure 17 has full control of your fan and light However air flow direction is controlled by a slide switch on the switch housing 1 Restore electrical power to the outlet box by turning t...

Страница 12: ...erference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rece...

Страница 13: ...or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Screws holding blades to 4 Tighten screws securely flanges are loose 5 Loose screws in motor housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is 1 Raise coupling cover and tighten excessively not tightened securely setscrew secur...

Страница 14: ...14 Repair Parts 10 16 12 3 2 1 5 4 7 6 14 21 19 23 HI OFF LOW MED 24 11 15 13 9 17 20 25 8 22 18 BP7284 Sturbrige KF180 7 31 06 10 52 AM Page 14 ...

Страница 15: ...Wiring 762729 762729 762729 18 Adapter Light Fitter 762730 AP 762730 DBK 762730 OZ 19 Rod Ring Assembly 6 762735 AP 762735 DBK 762735 OZ 20 Fitter Light 763207 763207 763207 21 Glass Lower 762733 762733 762733 22 Ring Assembly Lower 762734 AP 762734 DBK 762734 OZ 23 Screw Ring 6 762736 AP 762736 DBK 762736 OZ 24 Transmitter Remote Control 761970 1 761970 1 761970 1 25 Receiver Remote Control 76267...

Страница 16: ...factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized...