background image

8

Model No.: CF990

How to Hang Your Ceiling Fan

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 12).

CEILING

FLOOR

AT LEAST

7'

Figure 12

WARNING

!

The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support of 15.9
kg. (35lbs.) or less”.

WARNING

!

To reduce the risk of fire, electrical shock, or personal
injury, mount fan to outlet box marked “Acceptable for
Fan Support of 15.9 kg. (35lbs.) or less”, and use screws
supplied with outlet box. Most outlet boxes commonly
used for support of light fixtures are not acceptable for
fan support and may need to be replaced. Consult a
qualified electrician if in doubt.

WARNING

!

NOTE: CEILING COVER
OMITTED FOR CLARITY.

NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES 
OMITTED FOR CLARITY.

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

1-1/4" THREADED 
STUD (2)

Figure 14

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

WARNING

!

1.

Disconnect electrical power to the branch circuit at
the circuit breaker or fuse box before attempting to
install the ceiling fan wall control into the outlet box.

2.

Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box.
(Figure 13.)

3.

Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 13). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 14).

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 13

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.

WARNING

!

CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.

Содержание HIGHGROVE CF990BS00

Страница 1: ...Part No F40BP74640000 Form No BP7464 Model No CF990 READ AND SAVE THESE INSTRUCTIONS 54 Ceiling Fan Owner s Manual CF990BS00 CF990VNB00 Model Number HIGHGROVE Net Weight 27 5 Lbs ...

Страница 2: ...pport and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your...

Страница 3: ... The minimum wire would be a 3 conductor 2 wire with ground of the following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Before assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is da...

Страница 4: ...al shock WARNING WARNING To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 15 9 kg 35lbs oror less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING 1 Remove t...

Страница 5: ...te fan wobble 7 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approx imately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 8 Turn fan motor assembly upside down in preparation for mounting fan blades Position the top and bottom halves of the styrofoam packaging on e...

Страница 6: ...10 32 x 12 3mm washer head blade screws Figure 7 10 Slide the blade assembly into the housing slot Attach the blade assembly using two 1 4 x 1 2 round head lock tie flange screws Attach the remaining four blades Figure 8 NOTE Take care not to scratch fan housing when installing blades How to Put Your Ceiling Fan Together continued RUBBER SHIPPING RETAINERS MOTOR HOUSING ASSEMBLY Figure 6 BLADE MED...

Страница 7: ...the white wire connector from the ceiling fan to the white wire connector of the light kit assembly Figure 10 Connect the black wire connector from the ceiling fan to the black wire connector of the light kit assembly 14 Remove one of the one of the three screws in the lower housing and loosen the remaining two screws Figure 11 NOTE Make sure all wires and connector are tucked under the light kit ...

Страница 8: ...let box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING WARNING 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan ...

Страница 9: ...lack AC IN L wire d Securely connect the fan motor white wire to the receiver white TO MOTOR N wire e Securely connect the fan motor black wire to the receiver black TO MOTOR L wire f Securely connect the fan motor blue wire to the receiver blue FOR LIGHT wire g If installing the optional accessory AL100 accent light follow the AL100 installation instructions Turning off wall switch is not suffici...

Страница 10: ...f the ceiling fan is now complete Restore electrical power to the branch circuit at the fuse box or breaker panel Model No CF990 How to Wire Your Ceiling Fan continued 4 Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket Position the antenna wire on top of the receiver 5 Screw the two threaded studs supplied into the tapped holes in the ...

Страница 11: ...tch when the switch is turned OFF the control will remember the light intensity and fan speed When the switch is turned back ON the light and fan will resume operation as they we re prior to the switch being turned OFF Installation of Battery 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 20 2 Remove the connector from the battery compart...

Страница 12: ...UTTON STORAGE BRACKET TO INSTALL BRACKET TO WALL SLIDE THE COVER UP TO EXPOSE THE SCREW HOLES FOR INSTALLATION COVER SCREW HOLES 2 WALL BRACKET Figure 21 IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control has full control of your fan and light Figure 21 1 To set the desired fan speed press one of the fo...

Страница 13: ...tor housing 2 Check to make sure all screws in motor housing are snug not over tight 3 Wire connectors inside switch housing 3 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 4 Screws holding blades to flywheel 4 Tighten screws securely are loose 3 Fan wob...

Страница 14: ...14 Repair Parts 9 8 1 7 3 2 16 5 10 20 21 22 11 17 13 14 6 15 12 4 24 23 19 18 Model No CF990 ...

Страница 15: ...8 BS 764268 VNB 15 Harness Wiring 1 764285 1 764285 2 16 Lower Housing Assembly 1 764280 BS 764280 VNB 17 Light Kit Assembly 1 764281 WW 764281 WW 18 Light Kit Glass 1 764283 OM 764285 VC 19 Finial Nut 1 764284 BS 764284 VNB 20 Blade Flange set of 5 764274 BS 764274 VNB 21 Blades set of 5 764278 DM 764278 WA 22 Blade Medallions set of 5 764276 BS 764276 VNB 23 Receiver Remote Control 1 RCFP RCFP 2...

Страница 16: ...ave proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt...

Отзывы: