background image

READ AND SAVE THESE INSTRUCTIONS

Model No.

HF1160BK 00
HF1160WW 00

Part No. F40BP72720000

Form No. BP7272

®

Net Weight:  

19.8 

Lbs.

60” Industrial

Heat Fan

Owner's Manual

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for five years from the date you purchased your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the
motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Company will refund the actual purchase
price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and
shipping of the product to Emerson Company.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson

Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if
this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Содержание HF1160WW 00

Страница 1: ...n authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The gl...

Страница 2: ...lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with the fan blades 5 Suitable for use with solid stat...

Страница 3: ...s CAUTION The blade assemblies must be mounted on the motor assembly so that the This Side Up label is visible at the top of the motor Figure 1 1 Install one blade assembly on the top of the motor assembly using two M6 1 0 x 12mm Phillips hex head screws two split lockwashers and two flat washers supplied Figure 1 Repeat this procedure for the remaining two blade assemblies Electrical Requirements...

Страница 4: ... yoke It is critical that the clevis pin in the motor yoke is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling 4 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly instal...

Страница 5: ...and green leads on one side of the outlet box and the black leads on the other side of the outlet box 13 Screw the two 3 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 8 14 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 9 15 Secure the ceiling cover in place by sliding lockwashers over the th...

Страница 6: ... cable through the eye screw and then back through the two cable clamps CAUTION It is important to note the proper installation position of the cable clamps as illustrated in Figure 10 TO obtain maximum holding power install U bolt section of clip on dead or short end of cable and saddle on long end of cable Improper installation reduces the efficiency of the connection by as much as 40 percent 17...

Страница 7: ...ad Knurled M4 7 x 10mm 2 14 Lockwasher External Tooth M4 2 15 Wrench Setscrew 16 Clamp Safety Wire 2 17 Screw Eye 18 Cover Ceiling 762516 3 762516 15 19 Cover Motor 762494 762494 1 20 Capacitor 4 5 uF 762493 762493 21 Blade set of 3 762495 762495 1 22 Flange set of 3 762497 762497 1 Owner s Manual BP7272 BP7272 Before discarding packaging material be certain all parts have been removed HOW TO ORDE...

Страница 8: ...15 16 10 11 12 5 6 13 17 21 20 22 14 19 T H I S S I D E U P Part No F40BP72720000 Printed in Taiwan 02 04 Form No BP7272 Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Repair Parts ...

Отзывы: