background image

CAUTION: To reduce the risk of injury,
fire or damage to humidifier, use only
cleaners specifically recommended
for humidifiers. Never use flammable,
combustible or poisonous materials
to clean your humidifier. To reduce the
risk of scalds and damage to humidifi-
er, never put hot water in humidifier.

CAUTION: Local water purity may vary
from area to area and under certain
conditions water impurities and air-
borne bacteria may promote the
growth of microorganisms in the
reservoir of a humidifier.
To retard bacteria growth that may
cause odors and be harmful to your
health, use only Emerson recom-
mended filters. We also recommend
using EPA approved bacteriostat
available at your local store. Under no
circumstances should you use water
treatment products for Roto belt or
Ultrasonic humidifiers. Clean your
humidifier regularly.

Step 1

To make cleaning easier, the water reser-
voirs should be empty and the base should
be completely dried out.

Set Humidity Control all the way clockwise
and Air Flow Control to high. Run until base
is dry.

Step 2

When unit is dry, rotate Humidity Control to
off.

Step 3

Unplug humidifier, and proceed to clean.

WARNING: If humidifier is not un-
plugged, fan could start after housing is
removed.

Step 4

To Remove Parts

Remove the water reservoirs as indicated in
Step 1 of the “Water Fill” section in this own-
ers manual, on page 4. Remove back grille 

as shown on page 8, under Filter
Replacement Instructions, Step 1-2.

Step 5

Before removing filter, we recommend mov-
ing the humidifier to an area where floor
coverings are not susceptible to water dam-
age, i.e., kitchen or bath area. Remove the
filter from the unit, as shown on page 8,
Steps 3-4, under Filter Replacement
Instructions. Dispose of filters properly.
Remove mineral deposits from the humidifi-
er base by wiping with a clean damp cloth.
NOTE: Do not use any type of cleaner on
the filter.

Step 6

Install a new filter (Emerson HDC-1) into
the location where the old filter was posi-
tioned as shown on page 8, Steps 5-6.
Reattach grill to back of unit, as shown on
page 8, Steps 7-8. Return the humidifier to
the location wanted for use and install the
filled water reservoirs. Plug the unit into a
120 volt A.C. power outlet and set the con-
trols per the Operating Humidifier Controls
section of this manual.

Bi-Weekly Maintenance
Removing Scale

1. Fill the base with one 8oz. cup of undi-

luted white vinegar. Let solutions stay 20
minutes.

2. Clean all interior surfaces with a soft

brush. Dampen a soft cloth with undilut-
ed white vinegar and wipe out the base
to remove scale.

3. Rinse thoroughly with clean warm water

to remove scale and cleaning solution
before disinfecting the base.

Disinfecting Water Reservoirs and
Base

1. Fill water reservoir with 1 teaspoon chlo-

rine bleach in 1 gallon water. Let solu-
tion stay 20 minutes, swishing every few
minutes. Wet all surfaces.

2. Empty water reservoir after 20 minutes.

Rinse with water until bleach smell is
gone. Allow unit to dry out completely.

3. Repeat steps 1 thru 2 for other water

reservoir and base.

7

Cleaning of Humidifier

SP6295 - HD6000-2 Eng - 71234  7/12/05  3:24 PM  Page 7

Содержание HD60002

Страница 1: ...CAUTION Read all instructions carefully before installation Save this Owner s Manual for future reference Model No HD6000 2 MoistAIR HD6000 Evaporative Humidifier Owner s Manual EMERSON SP6295 HD6000 2 Eng 71234 7 12 05 3 24 PM Page 1 ...

Страница 2: ...nt misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipment improperly installed or wired or maintained in violation of this Owner s Manual No other written or oral warranty applies No employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Electric The customer shall be responsible for all costs in...

Страница 3: ...now Your Humidifier Humidifier Operations 3 Your new Moist AIR humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air After water is added to the unit the filter begins to soak up the water and become totally saturated in approximately 30 min utes Air is drawn in from the back of the humidifier by means of a circulation fan and drawn...

Страница 4: ...rmostat It is best to position humidifier next to an inside wall Hot air registers and cold air from outside walls can affect the efficiencies of the controls Unit should not be placed where warm air from a hot air register blows directly on unit Water Fill WARNING To reduce the risk of shock always unplug humidifier before cleaning or servicing Step 1 Remove water reservoir as shown Pivot the res...

Страница 5: ... assembly cap 6 Listen for air bubbles internally in the water reservoir Also look for water leaks around the fill cap 7 If you hear air bubbles or see water leaks retighten the fill cap and check for leaks again NOTE Failure to follow the above proce dures may result in unit overflowing with water Step 6 Wipe off any excess water from the bottle Step 7 To put water reservoir back in unit grasp wa...

Страница 6: ...OTE Humidifier should operate with humidity control on the recommended medium setting If it does not the humidity is at a relatively high level To test the unit under this condition turn Humidity Control all the way clockwise and unit should begin to operate After unit has been tested set Humidity Control to medium or desired level Allow 24 hours for humidifier to adjust If humidity level in home ...

Страница 7: ...5 Before removing filter we recommend mov ing the humidifier to an area where floor coverings are not susceptible to water dam age i e kitchen or bath area Remove the filter from the unit as shown on page 8 Steps 3 4 under Filter Replacement Instructions Dispose of filters properly Remove mineral deposits from the humidifi er base by wiping with a clean damp cloth NOTE Do not use any type of clean...

Страница 8: ...er in clean humidifier before next season begins 6 Bi Weekly Maintenance is recom mended if you do not plan to run the humidifier for one week or longer Filter may be rinsed in clear water only Take care not to damage paper Step 1 Insert screwdriver into lower right slot between grille and housing as shown Twist to open slot and pull grille to unsnap Repeat for left side Step 3 Grasp filter and ro...

Страница 9: ...sembly cap is not depressed Remedy Raise humidistat setting to test operation Check 120 volt source for power Turn humidity control clock wise and continue running until base becomes dry Check caps to ensure tight ness Check for leak in water reservoirs Ensure gaskets for caps are in place Change to a fresh new filter Check to make sure water reservoirs are properly seated Troubleshooting 9 FOR TE...

Страница 10: ...10 Repair Parts 2 3 4 5 6 8 12 10 11 13 15 14 16 17 9 7 1 Parts List For Emerson Humidifier Model No HD6000 2 SP6295 HD6000 2 Eng 71234 7 12 05 3 24 PM Page 10 ...

Страница 11: ... Manual Not Illustrated Any attempt to repair this motor may create a Hazard unless repair is done by a qualified service technician This assembly is factory aligned Stock Item May be purchased locally TO ORDER PARTS CALL USA 1 800 654 3545 Canada 1 866 808 6500 The model number will be found on the humidifier identification label Always mention the model number when requesting repair parts FOR TE...

Страница 12: ...ada 11 04 2000 2004 Emerson Electric Co FOR TECHNICAL HELP CALL 800 654 3545 FROM USA OR 888 744 4687 FROM CANADA Please have complete model number 9999 Highway 48 Markham Ontario Canada L3P 3J3 TM SP6295 HD6000 2 Eng 71234 7 12 05 3 24 PM Page 12 ...