Instruction Manual
D103435X012
V150E Valve
July 2017
9
Figure 4. Typical Fisher V150E Valve Showing Pry Bar
GE44766-A
ACTUATOR SIDE OF VALVE
BALL
THRUST AND BEARING SURFACE
PRY IN THIS DIRECTION
b.
For NPS 6x8 and larger valves,
the HD seal can be removed through the outlet end of the valve with the ball
installed. Carefully rotate the ball past the 90 degree open position until it is no longer in contact with the HD
seal.
CAUTION
Due to the ball shape, take care when you rotate either the front skirted edge or the circular back edge of the ball out of the
HD seal, as the seal could be damaged.
2. With the inlet side of the valve facing up, push the HD metal seal (key 11) into the valve body (key 1).
CAUTION
Exercise care to avoid damaging components in the following procedure.
D
It might be necessary to remove the HD metal seal by carefully tapping it with a soft punch and hammer. Take care
not to damage the valve body.