MR95 Series

3

To avoid such injury or damage, provide 

pressure-relieving or pressure-limiting devices 

(as required by the appropriate code, regulation 

or standard) to prevent service conditions from 

exceeding limits.
Additionally, physical damage to the regulator 

could result in personal injury and property 

damage due to escaping fluid. To avoid such 

injury and damage, install the regulator in a 

safe location.

Clean out all pipelines before installation of the regulator and check 

to be sure the regulator has not been damaged or has collected 

foreign material during shipping. For NPT bodies, apply pipe 

compound to the external pipe threads. For flanged bodies, use 

suitable line gaskets and approved piping and bolting practices. 

Install the regulator in any position desired, unless otherwise 

specified, but be sure flow through the body is in the direction 

indicated by the arrow on the body.

Note

It is important that the regulator be installed 

so that the vent hole in the spring case 

is unobstructed at all times. For outdoor 

installations, the regulator should be located away 

from vehicular traffic and positioned so that water, 

ice and other foreign materials cannot enter the 

spring case through the vent. Avoid placing the 

regulator beneath eaves or downspouts and be 

sure it is above the probable snow level. 

Overpressure Protection

The recommended pressure limitations are stamped on the 

regulator nameplate. Some type of overpressure protection is 

needed if the actual inlet pressure exceeds the maximum operating 

outlet pressure rating. Overpressure protection should also be 

provided if the regulator inlet pressure is greater than the safe 

working pressure of the downstream equipment.
Regulator operation below the maximum pressure limitations does 

not preclude the possibility of damage from external sources or 

debris in the line. The regulator should be inspected for damage 

after any overpressure condition.

Startup

The regulator is factory set at approximately the midpoint of the 

spring range or the pressure requested, so an initial adjustment 

may be required to give the desired results. With proper installation 

completed and relief valves properly adjusted, slowly open the 

upstream and downstream shutoff valves.

Adjustment

To change the outlet pressure, loosen the jam nut and turn 

the adjusting screw clockwise to increase outlet pressure or 

counterclockwise to decrease it. Monitor the outlet pressure with a 

test gauge during the adjustment. Tighten the jam nut to maintain 

the desired setting.

Taking Out of Service (Shutdown)

!

WARNING

To avoid personal injury resulting from sudden 

release of pressure, isolate the regulator from all 

pressure before attempting disassembly.

*Recommended Spare Part

1.  Only one metal diaphragm is needed for Types MR95L and MR95LD with 1/4 NPT body 

size and 0.14 to 0.41 bar / 2 to 6 psi spring range.

Parts List

Key   Description

1 Body

Spring Case

3* Orifice

4* 

Valve Plug, Metal seat

4* 

Disk Holder Assembly, Composition seat

4a 

Disk Holder

4b Disk

4c 

O-ring, Type MR95HP only (not shown)

Valve Plug Guide

Stem/Stem Assembly

6a Stem

6b 

Pusher Plate 

6b O-ring

6c O-ring

Stem Guide Bushing

Lower Spring Seat

Upper Spring Seat

10 

 Pusher Post, (not shown) 

11 

Control Spring

12* Diaphragm

(1)

13 Nameplate

14*   Diaphragm Protector (not shown)

15 

Adjusting Screw

16 

Cap Screw  

17 

Jam Nut

18 

Nameplate Drive Screw

19*  Diaphragm Gasket

20 

Pitot Tube (for constructions without control line)

21 

 Diaphragm Head Assembly,Types MR95L and MR95LD only

(not shown)

21a  Diaphragm Head

21b  Lower Spring Seat

21c Screw

21 

 Diaphragm Head (not shown)

22 

Adjusting Screw Assembly (Tee Handle Adjustment)

23 

Handwheel (not shown) 

26 

Inner Valve Spring

27 

 Inner Valve Base (not shown)

27 

 Inner Valve Base Assembly, Type MR95HP only (not shown)

29*   Gasket (not shown)

31 

 Locknut (not shown)

32 

Stuffing Box

33 

Adjusting Screw

34 

Packing Follower

35 

Stuffing Box Nut

36 Packing

37*  Stuff Box Gasket

38 Handwheel/Handle

39 

Internal Adaptor

40 

External Adaptor

41 

Machine Screw

41 

 Jam Nut, Types MR95HD and MR95HDP only

42 Spring

43 Washer

44 Washer

45*  O-ring, Types MR95HD and MR95HDP only (not shown)

47 

NACE Tag (not shown)

48 

Tag Wire (not shown)

49 

 Lockwasher (not shown)

50*  Sealing Washer

51 

 Vent, Type Y602-12 (not shown)

52 Plug

62 

 Adaptor, Types MR95L and MR95LD only (not shown)

63*  Bottom Plug Seal

64 

Flow Arrow

65 

Pipe Plug (not shown)

66 

Inlet Pressure Gauge (not shown)

67 

Outlet Pressure Gauge (not shown)

69 

ATEX Tag (not shown) 

70 

PED Tag (not shown)

Содержание Fisher MR95 Series

Страница 1: ...ice DN 20 and 25 3 4 and 1 in bodies 16 02 mm 0 631 in orifice DN 40 and 50 1 1 2 and 2 in bodies not available for Types MR95L and MR95LD 29 mm 1 142 in orifice 1 The pressure temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded 2 The pressure limits given are based on the body size and body materials only Actual pressure limits of th...

Страница 2: ...lloy C 3 Aluminum Bronze 3 68 9 1000 37 9 550 37 9 550 MR95HT 1 4 NPT and DN 15 to 25 1 2 to 1 in WCC LCC Steel 41 4 600 41 4 600 41 4 600 CF8M CF3M Stainless Steel Monel 3 Hastelloy C 3 Aluminum Bronze 3 41 4 600 37 9 550 37 9 550 DN 40 and 50 1 1 2 and 2 in WCC LCC Steel CF8M CF3M Stainless Steel Monel Hastelloy C Aluminum Bronze 41 4 600 31 0 450 31 0 450 1 The pressure temperature limits in th...

Страница 3: ...tallation completed and relief valves properly adjusted slowly open the upstream and downstream shutoff valves Adjustment To change the outlet pressure loosen the jam nut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease it Monitor the outlet pressure with a test gauge during the adjustment Tighten the jam nut to maintain the desired setting Taking ...

Страница 4: ...3 L2 L2 L1 19 41 33 L3 36 L1 37 11 2 16 7 4 26 63 L2 L1 L4 3 L2 5 43 32 38 44 35 34 39 40 42 9 8 12 1 20 6 12 52 6C 6A 6B 4B 4A OR 3 L2 2 METAL DIAPHRAGM OPTION CONTROL LINE OPTION COMPOSITION SEAT OPTION 1 Lubricants and sealants must be selected such that they meet the temperature requirements 2 Apply L2 anti seize compound on key 16 for Stainless steel bolts 3 Apply L4 graphite sealant instead ...

Отзывы: