Emerson Fisher 92S Скачать руководство пользователя страница 4

78

74

76

77

5

1

18

10

24

15

13

12

9

8

7

4

3

2

17

19

20

14

16

78

74

76

77

5

1

18

10

24

15

13

12

9

8

7

4

3

2

17

19

20

14

16

15

11

10

18

5

77

2

3

4

74

78

1

76

17

19

20

14

16

7

8

9

12

13

14

16

15

87

39A3514-B

39A3515-B

32A4712-A

A3505-1

TYPE 6492L PILOT

DETAIL OF TAPPED SPRING 

CASE WITH SEALED 

ADJUSTING SCREW

Figure 2.

 Pilot Assemblies

TYPE 6492H OR 6492HT PILOT

Type 92S

Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation

[email protected]

Emerson Automation Solutions

For further information on the current 

PED revision see Bulletin: 

D103053X012

or scan the QR code.

Fisher.com

Americas

 

McKinney, Texas 75070 USA 

T   +1 800 558 5853 

+1 972 548 3574

Europe

 

Bologna 40013, Italy 

T  +39 051 419 0611

Asia Pacific

 

Singapore 128461, Singapore 

T  +65 6777 8211

Middle East and Africa 

Dubai, United Arab Emirates 

T  +971 4 811 8100

D100637X014 © 2002, 2018 Emerson Process Management Regulator 

Technologies, Inc. All rights reserved. 07/18. 

The Emerson logo is a trademark and service mark of Emerson 

Electric Co. All other marks are the property of their prospective owners. 

Fisher™ is a mark owned by Fisher Controls International LLC, a 

business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes 

only, and while effort has been made to ensure their accuracy, they are 

not to be construed as warranties or guarantees, express or implied, 

regarding the products or services described herein or their use or 

applicability. All sales are governed by our terms and conditions, which 

are available on request. We reserve the right to modify or improve the 

designs or specifications of our products at any time without notice.

Emerson Process Management Regulator Technologies, Inc does not 

assume responsibility for the selection, use or maintenance of any 

product. Responsibility for proper selection, use and maintenance of any 

Emerson Process Management Regulator Technologies, Inc. product 

remains solely with the purchaser.

Содержание Fisher 92S

Страница 1: ...s lower Maximum Inlet and Outlet Pressures 2 See Table 1 Proof Test Pressure All Pressure Retaining Components have been proof tested per Pressure Equipment Directive Outlet Control Pressure Ranges 2 PILOT TYPE OUTLET PRESSURE RANGES bar psig 6492L 0 14 to 0 41 0 34 to 1 0 0 90 to 1 7 2 to 6 5 to 15 13 to 25 6492H 0 69 to 2 1 1 7 to 5 2 4 8 to 10 3 10 to 30 25 to 75 70 to 150 6492HT 1 0 to 6 9 5 5...

Страница 2: ...t hole in the spring case is unobstructed at all times For outdoor installations the regulator should be located away from vehicular traffic and positioned so that water ice and other foreign materials cannot enter the spring case through the vent Avoid placing the regulator beneath eaves or downspouts and be sure it is above the probable snow level Overpressure Protection The recommended pressure...

Страница 3: ...linder Gasket 19 Body Gasket 20 Upper Stem 21 Cylinder Spacer 22 Stem Seal Types 6492L 6492H and 6492HT Pilots Key Description 1 Body 2 Valve Plug Guide 3 Valve Plug Spring 4 Inner Valve 5 Orifice 7 Valve Stem 8 Bellows Retainer 9 Bellows 10 Diaphragm 11 Lower Spring Seat 12 Control Spring 13 Upper Spring Seat 14 Spring Case Key Description 15 Adjusting Screw 16 Hex Nut 17 Cap Screw 18 Diaphragm G...

Страница 4: ... 2018 Emerson Process Management Regulator Technologies Inc All rights reserved 07 18 The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Fisher is a mark owned by Fisher Controls International LLC a business of Emerson Automation Solutions The contents of this publication are presented for information purposes only a...

Отзывы: