Emerson Fisher 67D Series Скачать руководство пользователя страница 7

67D Series

7

       the valve seat (key 58) for damage or wear.  

      Replace part if damaged.  The valve stem may 

      be cleaned or replaced.  If the soft seat (key 15) 

       was removed, make sure it is properly snapped 

      into place before installing the valve stem.  Apply 

       a high quality lubricant to the O-ring (key 50) 

      before reinstalling the valve stem.
  4.  Slide valve plug (key 57) onto valve stem (key 11).

Apply lubricant to O-ring (key 14) and thread in 

spring retainer (key 48).  Torque spring retainer 

to 10 to 12 foot pounds (14 to 16 N•m).  Reinstall 

the filter gasket (key 66) and filter (key 6) and 

secure it with the filter retainer (key 9) and screw 

(key 65) and torque to 15 to 30-inch-pounds (1,7 to 

3,4 N•m).  Reinstall the O-ring (key 4), secure the 

dripwell with screws (key 3), and torque to 15 to               

30-inch-pounds (1,7 to 3,4 N•m).

Diaphragm Maintenance

Key numbers are referenced in Figures 5 and 6.
  1. Back out the adjusting screw or handwheel 

 (key 18) until compression is removed from the 

spring (key 17).

  2. Remove the six spring case screws (key 3) to  

       separate the spring case (key 7) from the body  

       (key 1).  Remove the upper spring seat (key 20)  

       and spring (key 17).
  3.  Remove the diaphragm assembly (key 16),       

       inspect the diaphragm, and replace the assembly, 

       if necessary.
  4. Place the diaphragm assembly (key 16) on the  

       body (key 1) as shown in Figure 5.  Push down on  

       the diaphragm assembly to make sure the valve  

       plug (key 57) strokes smoothly and approximately 

       1/16-inch (1,6 mm).

   

 

note

in step 5, if installing a control spring of 

a different range, be sure to delete the 

spring range originally appearing on the 

label and indicate the new spring range.

  5.  Stack the control spring (key 17) and upper spring  

       seat (key 20) onto the diaphragm assembly (key 16).
  6.  Install the spring case (key 7) on the body (key 1)  

       with the vent oriented to prevent clogging or entrance 

       of moisture.  Install the six spring case screws 

       (key 3) using a crisscross pattern and torque to 15 to  

       30-inch-pounds (1,7 to 3,4 N•m).

note

on Types 67DFS and 67DFSR, lubricate 

the adjusting screw (key 18) thread to 

reduce galling of stainless steel.

  7.  When all maintenance is complete, refer to the  

       Startup and Adjustment section to put the regulator  

       back into operation and adjust the pressure      

       setting.  Tighten the locknut (key 19) if used, and  

       install the closing cap (key 33) if used

 

 

 

 

 

 

 

 

Parts ordering

When corresponding with the local Sales Office about 

this regulator, include the type number and all other 

pertinent information printed on the label.  Specify 

the eleven-character part number when ordering new 

parts from the following parts list.
When ordering replacement parts, reference the key 

number of each needed part as found in the following 

parts list.  Separate kit containing all recommended 

spare parts is available.

Parts list

Key   Description                                                               Part number

 

Parts Kits

 

  Types 67D, 67DR, 67DS, and 67DSR

 - Includes seat (key 58),  

 

  O-rings (keys 14, 49, and 50), soft seat (key 15), and  

                 diaphragm assembly (key 16)
                 Type 67D (without relief)   

                 Brass and Nitrile (NBR) seat                               R67DX000012

               Type 67DR (with relief)

  

     Brass and Nitrile (NBR) seat                             R67DRX00012

               Types 67D NACE, 67DS, and

                 67DS NACE (without relief)

 

 

316L Stainless steel and Nitrile (NBR) seat     R67DSX00N12

     

    Types 67DR NACE, 67DSR, and

                 67DSR NACE (with relief)

                 316L Stainless steel and Nitrile (NBR) seat     R67DSRX0N12

 

  Types 67DF, 67DFR, 67DFS, and 67DFSR

 - Includes seat  

                (key 58), O-rings (keys 14, 49, and 50), soft seat (key 15),  

               

diaphragm assembly (key 16), 5 micron polyethylene filter  

                (key 6), filter gasket (key 66), dripwell O-ring (key 4), and  

 

 

  four screws (key 3).

     

    Type 67DF (without relief)

                 Brass and Nitrile (NBR) seat                              R67DFX00012

               Type 67DFR (with relief)

             Brass and Nitrile (NBR) seat                            

             Standard kit                                                     R67DFRX0012

             Low temperature kit (-60°F)                            R67DFRX0022

               Types 67DF NACE, 67DFS, and

                 67DFS NACE (without relief)

                 316L Stainless steel and Nitrile (NBR) seat    R67DFSX0N12

     

    Types 67DFR NACE, 67DFSR, and

                 67DFSR NACE (with relief)

 

      316L Stainless steel and Nitrile (NBR) seat   R67DFSRXN12

Содержание Fisher 67D Series

Страница 1: ... unit may be required Failure to correct trouble could result in a hazardous condition Installation operation and maintenance procedures performed by unqualified Introduction Scope of the Manual This manual provides instructions for the installation maintenance and parts ordering information for 67D Series regulators Instructions and parts lists for other equipment mentioned in this instruction ma...

Страница 2: ... Standard Bolting 20 to 180 F 29 to 82 C Stainless Steel Bolting 40 to 180 F 40 to 82 C With Fluorocarbon FKM Polyethylene Filter 4 Standard 0 to 180 F 18 to 82 C Polyvinylidene PVDF SST or Glass Filter Optional 0 to 300 F 18 to 149 C With Silicone VMQ 2 Diaphragm Low Temperature Nitrile NBR O rings and Low Temperature Bolting 60 to 180 F 51 to 82 C With Gauges 20 to 180 F 29 to 82 C With Automati...

Страница 3: ...ugh the regulator When demand increases downstream pressure drops slightly allowing the spring to extend moving the stem down and the valve plug away from the orifice This allows flow through the regulator Internal Relief Types 67DR 67DSR 67DFR and 67DFSR If for some reason outside of normal operating conditions the downstream pressure exceeds the setpoint of the regulator the force created by the...

Страница 4: ...0 to 1 4 0 to 2 4 0 to 4 1 0 to 8 6 GE07809T012 T14059T0012 T14058T0012 T14060T0012 Green stripe Unpainted Blue stripe Red stripe Music Wire 0 135 0 156 0 170 0 207 3 43 3 96 4 32 5 26 1 43 1 43 1 43 1 43 36 2 36 2 36 2 36 2 0 to 35 0 to 60 0 to 125 0 to 2 4 0 to 4 1 0 to 8 6 T14113T0012 T14114T0012 T14115T0012 Silver stripe Blue Red Inconel 0 156 0 172 0 207 3 96 4 37 5 26 1 43 1 43 1 43 36 2 36 ...

Страница 5: ...8 1 With proper installation completed and downstream equipment properly adjusted slowly open the upstream and downstream block valve when used while using pressure gauges to monitor pressure Warning To avoid personal injury property damage or equipment damage caused by bursting of pressure containing parts or explosion of accumulated gas never adjust the control spring to produce an outlet pressu...

Страница 6: ...y 4 Place the diaphragm assembly key 16 on the body key 1 as shown in Figure 3 or 4 Push down on the diaphragm assembly to make sure the valve plug key 57 strokes smoothly and approximately 1 16 inch 1 6 mm Note In step 5 if installing a control spring of a different range be sure to delete the spring range originally appearing on the label and indicate the new spring range 5 Stack the control spr...

Страница 7: ...x spring case screws key 3 using a crisscross pattern and torque to 15 to 30 inch pounds 1 7 to 3 4 N m Note On Types 67DFS and 67DFSR lubricate the adjusting screw key 18 thread to reduce galling of stainless steel 7 When all maintenance is complete refer to the Startup and Adjustment section to put the regulator back into operation and adjust the pressure setting Tighten the locknut key 19 if us...

Страница 8: ...luminum Manual GE34605X012 Auto drain GE34606X012 for Type 67DFS or 67DFSR Stainless steel Manual GE34607X012 Auto drain GE31792X012 6 Filter Element for Types 67DF 67DFR 67DFS and 67DFSR Polyethylene 5 microns standard GE31794X012 Glass fiber 5 microns GE31795X012 Polyvinylidene fluoride PVDF 40 microns GE31794X022 Stainless steel 40 microns GE31809X012 7 Spring Case for Type 67D 67DR 67DF or 67D...

Страница 9: ... T14061T0012 Handwheel T14102T0012 Wire seal not shown T14104T0012 Key Description Part Number 18 Adjusting Screw for Type 67D 67DR 67DF or 67DFR continued For spring case with 1 4 NPT vent Square head for closing cap Stainless steel T14101T0012 Handwheel Zinc plated steel T14103T0012 Wire seal not shown Steel T14198T0012 for Type 67DS 67DSR 67DFS or 67DFSR Square head with or without closing cap ...

Страница 10: ... 9 2 19 7 45 50 11 58 57 3 66 49 48 5 65 18 19 31 Figure 7 67D Series Optional Panel Mount 40C1728_A Figure 6 Type 67DFS or 67DFSR Assembly GE31805_B GE31784_C position 1 Aligned with inlet standard position 3 position 2 position 4 33 18 20 17 3 16 1 15 L L L L L 12 2 6 9 2 19 7 45 50 11 58 57 3 66 49 48 5 65 18 19 31 ...

Страница 11: ...nly Available with the 1 4 inch 6 4 mm Spring Case Vent B2698 Figure 11 Automatic Drain Option for Type 67DF 67DFR 67DFS or 67DFSR Figure 9 Key 16 Diaphragm Assembly RETAINING RING PUSHER POST WITHOUT RELIEF LOWER SPRING SEAT DIAPHRAGM PLATE PUSHER POST WITH RELIEF DIAPHRAGM B2696 L L 2 18 19 31 apply lubricant L ...

Страница 12: ...ion visit www fisherregulators com Key Description Part Number 22 Pressure Gauge not shown for Types 67D 67DR 67DF and 67DFR Brass 0 to 30 psig 0 to 2 1 bar 0 to 0 2 MPa 11B8579X022 0 to 60 psig 0 to 4 1 bar 0 to 0 4 MPa 11B8579X032 0 to 160 psig 0 to 11 0 bar 0 to 1 1 MPa 11B8579X042 for All Stainless Steel 0 to 30 psig 0 to 2 1 bar 0 to 0 2 MPa 11B9639X012 0 to 60 psig 0 to 4 1 bar 0 to 0 4 MPa ...

Отзывы: