Emerson Fisher 67C Скачать руководство пользователя страница 2

practices. Install the regulator in any position desired, 

unless otherwise specified, but be sure flow through 

the body is in the direction indicated by the arrow on 

the body.

note

It is important that the regulator be 

installed so that the vent hole in the 

spring case is unobstructed at all times. 

For outdoor installations, the regulator 

should be located away from vehicular 

traffic and positioned so that water, ice 

and other foreign materials cannot enter 

the spring case through the vent. Avoid 

placing the regulator beneath eaves or 

downspouts and be sure it is above the 

probable snow level.

Overpressure Protection

The recommended pressure limitations are 

stamped on the regulator nameplate. Some type of 

overpressure protection is needed if the actual inlet 

pressure exceeds the maximum operating outlet 

pressure rating. Overpressure protection should 

also be provided if the regulator inlet pressure 

is greater than the safe working pressure of the 

downstream equipment.
Regulator operation below the maximum pressure 

limitations does not preclude the possibility of damage 

from external sources or debris in the line. The 

regulator should be inspected for damage after any 

overpressure condition.

startup

The regulator is factory set at approximately 

the midpoint of the spring range or the pressure 

requested, so an initial adjustment may be required 

to give the desired results. With proper installation 

completed and relief valves properly adjusted, slowly 

open the upstream and downstream shutoff valves.

Parts List

Key  Description

  1 

Body

  2 

Drain Valve

  3 

Flange Screw

 4*

 

O-ring

  5 

Dripwell

 

 6*

 

Filter Element

  7 

Spring Case Assembly

  9 

Filter Retainer

 10*

(1) 

Valve Cartridge

 11*

(1) 

Valve Plug

 12*

(1) 

Valve Spring

 13*

(1) 

Valve Retainer

 

 14*

(1) 

O-ring

 15*

(1) 

Soft Seat

 16*

 

Diaphragm Assembly

 17  Spring

  18  Adjusting Screw

 19  Locknut

  20  Upper Spring Seat

  22  Pressure Gauge (not shown)

  23  Pipe Plug (not shown)

  24  Tire Valve (not shown)

 26*

 

Filter Gasket

  30  NACE Tag (not shown)

  31  Panel Mounting Nut

  32  Wire Seal (not shown)

  33  Closing Cap (not shown)

  34  Spacer (not shown)

  37*  Thrust Washer

  39  Bottom Plate

  45  Screen Vent

* Recommended Spare Part

1. Valve Cartridge Assembly includes keys 10, 11, 12, 13, 14 and 15.

Adjustment

To change the outlet pressure, remove the closing 

cap or loosen the locknut and turn the adjusting 

screw clockwise to increase outlet pressure or 

counterclockwise to decrease pressure. Monitor 

the outlet pressure with a test gauge during the 

adjustment. Replace the closing cap or tighten the 

locknut to maintain the desired setting.

Taking Out of Service (Shutdown)

!

WarnIng

To avoid personal injury resulting from 

sudden release of pressure, isolate the 

backpressure regulator from all pressure 

before attempting disassembly.

67C and 67CF Series

2

Содержание Fisher 67C

Страница 1: ...rdance with international and applicable codes and regulations and Emerson Process Management Regulator Technologies Inc instructions If the regulator vents fluid or a leak develops in the system it indicates that service is required Failure to take the regulator out of service immediately may create a hazardous condition Personal injury equipment damage or leakage due to escaping fluid or burstin...

Страница 2: ...int of the spring range or the pressure requested so an initial adjustment may be required to give the desired results With proper installation completed and relief valves properly adjusted slowly open the upstream and downstream shutoff valves Parts List Key Description 1 Body 2 Drain Valve 3 Flange Screw 4 O ring 5 Dripwell 6 Filter Element 7 Spring Case Assembly 9 Filter Retainer 10 1 Valve Car...

Страница 3: ...llation IN 34 B2697 SPACER SPACER OUTER DIAMETER 13 0 50 OD SPACER WIDTH AND INNER DIAMETER 8 1 0 32 4 6 0 18 ID T14123 17 10 26 6 4 3 9 5 13 37 2 12 11 14 L1 15 1 20 31 18 L2 apply lubricant l T40580 L1 MULTI PURPOSE POLYTETRAFLUOROETHYLENE PTFE LUBRICANT L2 ANTI SEIZE COMPOUND 67C and 67CF Series 3 ...

Страница 4: ... Process Management Regulator Technologies Inc All rights reserved 05 17 The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Fisher is a mark owned by Fisher Controls International LLC a business of Emerson Automation Solutions The contents of this publication are presented for information purposes only and while effo...

Отзывы: