Emerson Fisher 1808 Скачать руководство пользователя страница 1

Bulletin 71.4

D100163X012

Type 1808

December 2019

TYPE 1808

TYPE 1808A

Figure 1. 

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Introduction

The Type 1808 globe-style and the Type 1808A angle-style, 

pilot-operated relief valves or backpressure regulators are 

economical, compact devices used in gas or liquid service to 

maintain pressure on oil and gas separators and in pressure 

relief applications in gas distribution systems. These units 

control pressures from 3 to 125 psig / 0.21 to 8.6 bar and the 

set pressure is varied to individual requirements by the adjusting 

screw on the pilot.

Features

• 

Product Longevity—

The measuring element 

(diaphragm) is not in the direct flow path which could lead 

to unwanted wear and tear from debris in the flow path.

• 

Simple, In-line Field Maintenance—

With the removal of 

just two nuts, the actuator assembly lifts away, exposing 

the trim and leaving the main valve body in the pipeline. 

• 

Minimize Field Interference Fits and Complicated 

Piping—

Internal pressure registration eliminates the need 

to install a control line. Most mounting orientations can be 

obtained due to the minimized piping interferences.

• 

Simple, Reliable Design—

The simple design 

has fewer parts for reliable service and minimum 

spare parts inventory.

• 

Compact and Lightweight—

Less than 12 in. / 305 mm 

tall and weighs 25 lbs / 11 kg or less, these units are easily 

transported and installed where space is limited.

• 

Versatility in Both Liquid and Gas Service—

Pilot exhaust 

port and standard tapped pilot spring case (Figure 2) 

both come with removable vent for remote piping when 

necessary. The standard tapped pilot spring case comes 

complete with a gasketed closing cap that permits pressure 

loading for remote pneumatic adjustment of the set pressure.

• 

Optional Upstream Registration for Reduced 

Buildup—

For gas service with the Type 6358B pilot, 

upstream control line construction is available to 

provide wide-open relief flow capacity with less buildup 

regardless of set pressure.

• 

Self-Draining Body—

The Type 1808A angled body 

design has increased capacity and provides complete 

process fluid drainage from body cavity during shut-down 

period or before disassembly of the main valve.

Types 1808 and 1808A Pilot-Operated Relief 

Valves or Backpressure Regulators

Содержание Fisher 1808

Страница 1: ...nates the need to install a control line Most mounting orientations can be obtained due to the minimized piping interferences Simple Reliable Design The simple design has fewer parts for reliable service and minimum spare parts inventory Compact and Lightweight Less than 12 in 305 mm tall and weighs 25 lbs 11 kg or less these units are easily transported and installed where space is limited Versat...

Страница 2: ...djusting Screw Zinc plated steel O rings Nitrile NBR or Fluorocarbon FKM Closing Cap Plastic or Stainless steel Connector Cap Stainless steel Mounting Parts Tubing Stainless steel Fittings Steel or Stainless steel Pipe Tees Galvanized steel Pipe Nipples Malleable Iron Galvanized Steel and Stainless Steel Options Upstream control line construction Pressure gauge 0 to 160 psig 0 to 11 0 bar 0 to 1 1...

Страница 3: ...e 1 Available Configurations TYPE PILOT TYPE DESCRIPTION 1808 6358 Globe style body for backpressure applications 6358B Globe style body for relief applications 1808A 6358 Angle style body for backpressure applications 6358B Angle style body for relief applications Table 2 Types 6358 and 6358B Set Pressure Ranges Pressure Ratings and Pilot Spring Information SET PRESSURE RANGE PILOT SPRING INFORMA...

Страница 4: ...808 and 1808A relief valves or backpressure regulators may be installed in any position as long as the flow through the main valve corresponds with the flow arrow on the main valve body Type 1808 or runs in through the bottom connection and out through the side connection Type 1808A An upstream control line is not required because of the integral pilot supply tubing however for a more accurate rel...

Страница 5: ... 10 15 20 25 30 10 000 20 000 30 000 40 000 50 000 60 000 70 000 Upstream Pressure psig Upstream Pressure psig Upstream Pressure psig Upstream Pressure psig Flow Rate SCFH of 0 6 SG Natural Gas 0 5 10 15 20 25 30 10 000 20 000 30 000 40 000 50 000 60 000 70 000 80 000 90 000 Flow Rate SCFH of 0 6 SG Natural Gas Flow Rate SCFH of 0 6 SG Natural Gas Flow Rate SCFH of 0 6 SG Natural Gas TYPE 1808 GRE...

Страница 6: ...000 300 000 350 000 400 000 20 40 60 80 100 120 140 0 50 000 100 000 150 000 200 000 250 000 300 000 320 000 20 40 60 80 100 120 140 Flow Rate SCFH of 0 6 SG Natural Gas Flow Rate SCFH of 0 6 SG Natural Gas TYPE 1808 RED CONTROL SPRING 1K74857202 35 TO 125 psig 2 4 TO 8 6 bar SET PRESSURE RANGE TYPE 1808A RED CONTROL SPRING 1K748527202 35 TO 125 psig 2 4 TO 8 6 bar SET PRESSURE RANGE Upstream Pres...

Страница 7: ...TO BEGIN OPENING MAIN VALVE 2 BUILDUP OVER SET PRESSURE TO FULLY OPEN MAIN VALVE 3 PRESSURE DROPBELOW SET PRESSURE TO RESEAT PILOT CAPACITIES OF 0 6 SPECIFIC GRAVITY NATURAL GAS 4 5 psig bar psig bar psig bar psig bar psig bar SCFH Nm3 h 3 to 18 0 21 to 1 2 3 5 10 15 0 21 0 35 0 69 1 0 0 9 0 7 0 7 0 7 0 06 0 05 0 05 0 05 6 0 4 0 1 2 1 0 0 41 0 28 0 08 0 07 1 0 0 07 37 000 37 000 42 000 52 000 992 ...

Страница 8: ...ings Upstream Control Line Construction Optional Yes Gauge Optional Yes Pilot Supply Filter Optional Yes Main Valve Parts Kit Optional Yes please send one parts kit to match this order Pilot Parts Kit Optional Yes please send one parts kit to match this order Fisher com Emerson Automation Solutions Americas McKinney Texas 75070 USA T 1 800 558 5853 1 972 548 3574 Europe Bologna 40013 Italy T 39 05...