TYPE
MAXIMUM INLET PRESSURE
MAXIMUM EMERGENCY
OUTLET PRESSURE OR MAXIMUM
EMERGENCY SENSE PRESSURE
(1)
MAXIMUM BLEED (EXHAUST) PRESSURE
FOR MONITOR PILOTS
psig
bar
psig
bar
psig
bar
161
1500
103
1200
82.7
- - - -
161AY
150
10.3
150
10.3
161EB and 161EBH
1500
103
1200
82.7
161M
1500
103
1200
82.7
1500
103
161AYM or 161AYW
150
10.3
150
10.3
150
10.3
161EBM and 161EBHM
1500
103
1200
82.7
1500
103
1. Maximum pressure to prevent the casings from bursting during abnormal operation (leaking to atmosphere and internal parts damage may occur).
PILOT TYPE
OUTLET (CONTROL)
PRESSURE RANGE
PROPORTIONAL
BAND
(1)(2)(3)
PILOT CONTROL SPRING INFORMATION
Part Numbers
Color Code
Wire Diameter
Free Length
psig
bar
psig
bar
In.
mm
In.
mm
161 or 161M
5 to 15
0.34 to 1.03
2
0.14
1E392527022
Yellow
0.148
3.76
2.00
50.8
10 to 125
0.69 to 8.62
2
0.14
1K748527202
Red
0.192
4.88
2.19
55.6
120 to 300
8.3 to 20.7
6
0.41
15A9258X012
Green
0.243
6.17
1.88
47.8
161AY, 161AYM
or 161AYW
6 to 15 in. w.c.
(4)
15 to 37 mbar
(4)
1 in. w.c
2 mbar
1B653927022
Olive Green
0.105
2.67
3.75
95.2
0.5 to 1.2
(5)
0.03 to 0.08
(5)
1 in. w.c
2 mbar
1B537027052
Yellow
0.114
2.90
4.31
109
1.2 to 2.5
(6)
0.08 to 0.17
(6)
0.5
0.03
1B537127022
Green
0.156
3.96
4.06
103
2.5 to 4.5
0.17 to 0.31
0.5
0.03
1B537227022
Light Blue
0.187
4.75
3.94
100
4.5 to 7
0.31 to 0.48
0.5
0.03
1B537327052
Black
0.218
5.54
3.98
101
161EB or
161EBM
5 to 15
0.34 to 1.03
0.5
0.03
17B1260X012
White
0.120
3.05
3.75
95.2
10 to 40
0.69 to 2.76
0.5
0.03
17B1262X012
Yellow
0.148
3.76
3.75
95.2
30 to 75
2.07 to 5.17
0.6
0.04
17B1259X012
Black
0.187
4.75
4.00
102
70 to 140
4.83 to 9.65
1.3
0.09
17B1261X012
Green
0.225
5.71
3.70
94.0
130 to 200
8.96 to 13.8
1.5
0.10
17B1263X012
Blue
0.262
6.66
3.85
97.8
200 to 350
13.8 to 24.1
3
0.21
17B1264X012
Red
0.294
7.47
4.22
107
161EBH or
161EBHM
250 to 450
17.2 to 31.0
3.5
0.24
(7)
17B1263X012
Blue
0.262
6.66
3.85
97.8
400 to 700
27.6 to 48.2
7
0.48
(7)
17B1264X012
Red
0.294
7.47
4.22
107
1. Proportional band includes outlet pressure drop plus hysteresis (friction), but does not include lockup.
2. Proportional band was determined with a pressure drop ranging from 50 to 150 psig / 3.4 to 10.3 bar. Approximately double the proportional band if the pressure drop is less than
50 psig / 3.4 bar.
3. With Type 112 restrictor set on 2.
4. The spring ranges for the Type 161AYW is 3 to 12 in. w.c. / 7.5 to 30 mbar.
5. The spring ranges for the Type 161AYW is 11 to 25 in. w.c. / 27 to 62 mbar.
6. The spring ranges for the Type 161AYW is 0.9 to 2.5 psig / 0.06 to 0.17 bar.
7. Proportional band was determined with a pressure drop ranging from 100 to 300 psig / 6.9 to 20.7 bar. Approximately double the proportional band if the pressure drop is less than
100 psi / 6.9 bar
Table 1.
Outlet (Control) Pressure Ranges, Proportional Bands and Pilot Control Spring Information
Table 2.
Pilot Pressure Ratings
Specifications
The Specifications section lists pressure limitations and other specifications for all models of 161 Series pilots.
Please note that the pilot control spring range is marked on the spring case of 161 and 161EB Series pilots and
on the nameplate of 161AY Series pilots.
Outlet (Control) Pressure Ranges
See Table 1
Proportional Bands
See Table 1
Maximum Inlet Pressure
(1)
See Table 2
Pilot Flow Coefficients
See Table 3
Options
Type 252 Pilot supply filter
Pilot Sping Case Vent
1/4 NPT (internal)
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2
161 Series