Emerson Fisher 133H Скачать руководство пользователя страница 5

133 Series

5

Table 1.  

133 Series Outlet Pressure Ranges, Control Springs

TYPE

OUTLET PRESSURE RangE

COnTROL SPRIngS 

Inches w.c./Psig

bar/mbar

Part number

Color Code

Stripe

Free Length,

 Inch (mm)

Wire Diameter,

 Inch (mm)

133H

(1)

1.5 to 3 psig

   2 to 5 psig

     5 to 10 psig

0,10 to 0,21 bar

0,14 to 0,34 bar

0,34 to 0,69 bar

1H975927032

10A9440X012

1J146927142

Orange

Yellow

Blue

7-3/8 (187)

6-15/32 (164)

6-3/16 (157)

0.250 (6,35)

0.283 (7,19)

0.375 (9,53)

133HP

(1)

 2 to 5 psig

4.5 to 10 psig

   6 to 20 psig

 16 to 30 psig

 26 to 40 psig

 36 to 50 psig

 45 to 60 psig

0,14 to 0,34 bar

0,31 to 0,69 bar

0,41 to 1,38 bar

1,10 to 2,07 bar

1,79 to 2,76 bar

2,48 to 3,45 bar

3,10 to 4,14 bar

17B8632X012

17B8633X012

10C1238X012

10C1240X012

10C1241X012

10C1242X012

10C1243X012

Yellow

Orange

Silver

Red

Blue

 Green

White

8-1/2 (216)

8-1/2 (216)

8-1/4 (210)

8-1/4 (210)

8-1/4 (210)

8-1/4 (210)

8-1/4 (210)

0.281 (7,14)

0.343 (8,71)

0.406 (10,31)

0.500 (12,70)

0.500 (12,70)

0.531 (13,49)

0.225 (5,72)

133L

(1)

 

and 

133H

(2)

              2 to 4-inches w.c.

           3.5 to 6-inches w.c.

              5 to 9-inches w.c.

           8.5 to 18-inches w.c.

            14 to 28-inches w.c.

         0.75 to 2 psig

     5,00 to 10,00 mbar

     9,00 to 15,00 mbar

   12,00 to 22,00 mbar

   21,00 to 45,00 mbar

   35,00 to 70,00 mbar

0,05 to 0,14 bar

1D892527022

1D892627022

1D892727012

1D893227032

1D893327032

1H975827032

Brown

Red

Black

White

Green

Blue

6-1/8 (156)

7-1/2 (190)

7-7/8 (200)

7-1/2 (190)

7-1/4 (184)

7-3/8 (187)

0.109 (2,77)

0.120 (3,05)

0.130 (3,30)

0.156 (3,96)

0.182 (4,62)

0.225 (5,72)

133Z

(1)

      -1 to 1-inch w.c.

   -2,00 to 2,00 mbar

1K633427012

(Extension Spring)

Black

2 (50,80)

0.075 (1,91)

          0 to 4-inches w.c.

           0 to 10,00 mbar

1K633427012

(Extension Spring) 

and 

1D892527022

(Composition Spring)

Black

Brown

2 (50,80)

6-1/8 (156)

0.075 (1,91)

0.109 (2,77)

  1.  Pressure ranges shown are correct if the regulator is installed with the actuator portion above the body portion.  If the regulator is installed with the actuator portion below the body,     

       the pressure ranges will be lowered by approximately 2-inches w.c. (5,00 mbar) for the Type 133L and by approximately 3-inches w.c. (7,00 mbar) for the Types 133H and 133Z.

  2.  If the 2-inches w.c. to 2 psig (5,00 mbar to 0,14 bar) springs (all 6 ranges) are used in the Type 133H, the pressure ranges will increase  by approximately 1-inch w.c. (2,00 mbar) due 

       to the weight of the Type 133H parts (assuming that the actuator is installed above the body).

PRESSURES

TYPE nUMBER

133H

Psig (bar)

133HP

Psig (bar)

133L

Psig (bar)

133Z

Psig (bar)

Maximum Operating Inlet Pressure

        60 (4,14)

150 (10,34)

       60 (4,14)

20 (1,38)

Maximum Emergency Inlet Pressure

      125 (8,62)

150 (10,34)

     125 (8,62)

125 (8,62)

Maximum Operating Outlet Pressure

(1)

        10 (0,69)

Setpoint Plus 40 psi (2,76) 

         2 (0,14)

4-inches w.c. (10,00 mbar)

Maximum Outlet Pressure Over Outlet Pressure Setting           3 (0,21)

- - - -

         3 (0,21)

3 (0,21)

Maximum Emergency Outlet (Casing) Pressure

        15 (1,03)

150 (10,34)

       15 (1,03)

15 (1,03)

  1.  With highest spring range available only.

Table 2.

  Maximum Inlet and Outlet Pressures

Startup

If the downstream system is already 

pressured by another regulator or by a 

manual bypass, then extra precautions 

must be taken when placing the 133 Series 

in service.  The outlet of the regulator 

must never be subjected to pressures 

higher than the inlet pressure, or the 

balancing diaphragm may be damaged. 

also, the control line pressure must never 

exceed the set point dictated by the spring 

!

WaRnIng

setting by more than 3 psig (0,21 bar), or 

the valve seat or diaphragm plates can be 

damaged.  The procedure used in putting 

the regulator in service must be planned 

accordingly.  Pressure gauges should 

always be used to monitor downstream 

and control line pressures during startup.

If the downstream system is not pressured by 

another regulator or by manual bypass, use the 

following procedure.
  1.  Slowly open the upstream shutoff valve.
  2.  Slowly open the downstream shutoff valve.
  3.  Check all connections for leaks.

Содержание Fisher 133H

Страница 1: ...ation for the 133 Series Warning Only personnel qualified through training or experience should install operate and maintain this regulator If there are any questions concerning these instructions contact your local Sales Office before proceeding Description The 133 Series self operated gas regulators shown in Figure 1 are primarily designed for industrial and commercial applications supplying gas...

Страница 2: ...struction Materials Body Cast iron or Steel Orifice and Cage Aluminum Valve Disk Aluminum Neoprene CR O Rings Nitrile NBR Diaphragms Nitrile NBR Nylon PA neoprene CR in actuator Guide Bushing Nylon Stem and Stem Sleeve Stainless steel Diaphragm Plate Steel Balancing Diaphragm Plate Plated Steel Spring Case Type 133 HP Cast Iron Types 133H 133L and 133Z Aluminum Lower Casing Aluminum Closing Cap Ca...

Страница 3: ...oles in the top of the cage Also downstream pressure is registered on the bottom of the valve disk and on the top of the balancing diaphragm through a passage formed by grooves in the registration disk and an annular space between the stem and stem sleeve When the valve disk is open gas flows from the inlet over the edge of the valve disk to the outlet Under the valve disk near the registration di...

Страница 4: ... the 133 Series regulators in operation Without the control line the regulator will remain wide open The downstream control line should be a pipe of at least 1 2 inch 12 7 mm diameter connect it to the downstream pipe line at least 5 to 10 pipe diameters from the regulator and in a straight section of pipe The external downstream control line connection on the Type 133HP is 1 4 inch threaded NPT V...

Страница 5: ...If the regulator is installed with the actuator portion below the body the pressure ranges will be lowered by approximately 2 inches w c 5 00 mbar for the Type 133L and by approximately 3 inches w c 7 00 mbar for the Types 133H and 133Z 2 If the 2 inches w c to 2 psig 5 00 mbar to 0 14 bar springs all 6 ranges are used in the Type 133H the pressure ranges will increase by approximately 1 inch w c ...

Страница 6: ...ent Do not loosen the diaphragm casing cap screws keys 35 and 36 when the control spring key 12 has spring force applied to it Release the spring compression as described in step 6 Due to normal wear that may occur in gas regulators parts must be periodically inspected and replaced if necessary The frequency of inspection depends on the severity of service conditions or state and federal laws This...

Страница 7: ...key 42 Remove the compression spring key 12 if one is used 8 Unscrew the cap screws and nuts keys 35 and 36 and remove the spring case 9 Pull out the diaphragm and stem as assembly replace diaphragm and sealing washer key 17 if necessary When removing or replacing the diaphragm clamp the smallest diameter portion if the stem in a vise while turning the nut key 20 10 If necessary replace the guide ...

Страница 8: ...vent pipe if one is used 2 Unscrew the four locknuts key 34 and lift the actuator portion off the body key 1 All of the trim parts will come out of the body with the actuator The valve disc key 28 orifice key 2 and restriction collar key 46 can now be inspected caution Use care in performing step 3 to guard against damage to the balancing diaphragm key 22 3 Insert a 1 2 inch 12 70 mm open end wren...

Страница 9: ...be G or an equivalent elastomer sealant and lubricant 18 20 13 61 Protect the O Ring Surface from damage 3 4 inch 19 05 mm stem hex 16 58 14 15 A7007 Figure 7 Stem and Diaphragm Assembly 1 With the Type 133HP completely disassembled start the reassembly by applying Magnalube G or an equivalent to the stem threads key 18 and O ring key 61 Place the sealing diaphragm plate key 16 on the stem followe...

Страница 10: ...CONTROL LINE CONNECTION A7008 IL Figure 8 Lower Casing and Casing Adaptor Assembly WHEN ASSEMBLING THE ACTUATOR THE UPPER CASING AND ADAPTER SHOULD BE POSITIONED SO THAT TWO HOLES IN THE 5 1 4 INCH 133 mm BOLT HOLE CIRCLE ARE EQUALLY SPACED OVER THE CONTROL CONNECTION A7009 IL Figure 9 Diaphragm Casing Assembly 53 7 6 19 54 60 32 39 51 ...

Страница 11: ... 20 or 31 to prevent twisting of the main and balancing diaphragms keys 15 and 22 12 Install the valve disk key 28 registration disk key 29 washer key 30 and hex nut key 31 onto the stem The registration disk key 29 is marked for proper placement be certain it is positioned correctly on the stem key 18 Tighten the hex nut key 31 using the 1 2 inch 12 7 mm wrench flats on the stem sleeve 13 Insert ...

Страница 12: ...819012 Key Description Part Number 10 Closing Cap Gasket neoprene CR Types 133H 133L and 133Z 1N446206992 Type 133HP 1R742604022 11 Adjusting Screw Type 133H brass 1V9069X0012 Type 133L aluminum 1L928608012 Type 133Z brass 1K633714012 Type 133HP steel 1H139731012 12 Spring steel Type 133H 1 5 to 3 psig 0 10 to 0 21 bar Orange 1H975927032 2 to 5 psig 0 14 to 0 34 bar Yellow 10A9440X012 5 to 10 psig...

Страница 13: ...scription Part Number 12 Spring steel continued Blue 10C1241X012 36 to 50 psig 2 48 to 3 45 bar Green 10C1242X012 45 to 60 psig 3 10 to 4 14 bar White 10C1243X012 13 Spring Seat plated steel Types 133H 133L and 133Z 10A3052X012 Type 133HP 12B3518X012 14 Diaphragm Plate steel Type 133H 1 required 1D555725012 Type 133L 1 required 1J881725072 Type 133Z 2 required 1J881725072 Type 133HP 1 required 1D5...

Страница 14: ...133 Series 14 Figure 13 Optional Restriction Collar Assembly Figure 12 Type 133Z Assembly 40A3071 DC DOW CORNING NO 3 NS NEVER SEEZ ...

Страница 15: ...133 Series 15 A7010 IL Figure 14 Type 133HP Actuator Assembly A7011 IL ...

Страница 16: ...aluminum 1D5297X0012 Type 133HP 1A413224122 21 Diaphragm Plate plated steel 10A3054X012 22 Diaphragm nitrile NBR and nylon PA 10A3055X012 23 Washer plated steel 2 required 10A3056X012 24 Guide Bushing nylon PA 10A3057X012 25 Stem Sleeve 303 stainless steel 10A3061X012 26 E Ring plated steel 1F599428982 27 Roll Pin steel 1E954028992 28 Valve Disk Assembly aluminum neoprene CR 10A3058X012 29 Registr...

Отзывы: