1-6-4
TD300EA
7. White Balance Adjustment
Purpose:
To mix red, green and blue beams correctly
for pure white.
Symptom of Misadjustment:
White becomes bluish
or reddish.
Note:
Use service remote control unit
1. Operate the unit more than 20 minutes.
2. Face the unit to east. Degauss the CRT using De-
gaussing Coil.
3. Input the White Raster (APL 100%).
4. Set the color analyzer to the CHROMA mode and
after zero point calibration, bring the optical recep-
tor to the center on the tube surface (CRT).
5. Enter the Service mode. Press [VOL
p
] button on
the service remote control unit and select "C/D"
mode. (Display changes "C/D," "7F," and "DVD-
KEY" cyclically when [VOL
p
" button is pressed.)
Then press [8] button on the Service remote con-
trol Unit.
6. Press [4] button on the service remote control unit
for Red adjustment. Press [5] button on the service
remote control unit for Blue adjustment.
7. In each color mode, press [CH
o
/
p
] button to ad-
just the values of color.
8. Adjusting Red and Blue color so that the tempera-
ture becomes 9200K (x: 286 / y: 294) ±3%.
9. At this time, re-check that Horizontal line is white.
If not, Re-adjust Cut-off Adjustment until the Hori-
zontal Line becomes pure white.
10. Turn off and on again to return to normal mode. Re-
ceive APL 100% white signal and Check Chroma
temperatures become 9200K (x: 286 / y: 294) ±3%.
Note:
Confirm that Cut Off Adj. is correct after this
adjustment, and attempt Cut Off Adj. if needed.
8. Sub-Brightness Adjustment
Purpose:
To get proper brightness.
Symptom of Misadjustment:
If Sub-Brightness is
incorrect, proper brightness cannot be obtained by
adjusting the Brightness Control.
Note:
IQW Setup level --- 7.5 IRE
Use service remote control unit
1. Enter the Service mode. (See page 1-6-1)
Then input IQW signal from RF Input.
2. Press [PICTURE] button on the service remote con-
trol unit and Select "BRT" mode. (Display changes
"BRT," "CNT," "CLR," "TNT," and "V-TINT" cycli-
cally when PICTURE button is pressed.) Press [CH
o
/
p
] buttons so that the bar is just visible (See
above figure).
3. Turn the power off and on again, using the main
power button on the TV unit.
Test Point
Adj. Point
Mode
Input
Screen
CH
o
/
p
buttons
RF
White Ras-
ter (APL
100%)
Tape
M. EQ.
Spec.
Pattern
Generator,
Color analyzer
See below
Figure
Color Analyzer
Fig. 2
Test Point
Adj. Point
Mode
Input
---
CH
o
/
p
buttons
RF
IQW
Tape
M. EQ.
Spec.
---
Pattern
Generator
See below
Figure
White
Black
Fig. 3
This bar
just
visible
Содержание EWC09D5B