background image

 

1592010820 XWE B5000 PRO  STP GB r1.0 25.11.2020.docx                                                      XWEB5000 P RO                                                                    

   4/20 

 

CAUTION:  TO  PREVENT  FLAMES  FROM  DEVELOPING  OR  ELECTRIC  SHOCK, 
AVOID ANY CONTACT BETWEEN THIS DEVICE AND RAIN OR WATER 

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC 
SHOCK, DO NOT REMOVE  THE COVER IT DOES NOT 
CONTAIN ANY PARTS  THAT REQUIRE  SERVICING  BY 
THE USER ALWAYS  HAVE  QUALIFIED STAFF 
PERFORM THE PROCEDURES.

 

 

THE SYMBOL  OF THE LIGHTNING BOLT INSIDE  AN 
EQUILATERAL  TRIANGLE IS USED TO ALERT THE 
USER OF THE POTENTIALLY  DANGEROUS  NON-
INSULATED  ELECTRICAL  VOLTAGES

 

 

THE SYMBOL  OF THE EXCLAMATION  MARK INSIDE 
AN EQUILATERAL  TRIANGLE  IS USED TO WARN THE 
USER THAT HE/SHE  MUST PAY  CLOSE ATTENTION 
TO THE TOPIC COVERED  IN THIS MANUAL

 

 

CAUTION 

 

This device must be installed exclusively by service staf f wit h s uit able t ec hnic al 
training and experience, who are aware of the dangers that t hey  are ex posed t o. 
The operations described herein are set forth exclusively for the service s t af f.  The 
user is not enabled to open the device. 

 

 

CAUTION 

 

Use only modems and usb-dongles officially supported by this monitoring unit. Dixell 
srl. cannot be held responsible for any type of damage res ult ing f rom t he us e of 
unsupported devices. 

 

 

CAUTION 

 

Dixell srl reserves the right to amend this manual without p rior not ic e. The lat es t 
available version can be downloaded from the internet site. 

 

 

CAUTION 

 

Immediately after the power failure, no new data is recorded; all recorded d ata is  
kept  in  non-volatile  memory.  The  memory  is  electronic  and  no  data  is  kept or 
conveyed to other media such as paper. When the memory is exhausted, the oldest  
data  is  lost  to  store  the  most  recent  data.  The  product  provides  memory 
consumption indications on the user interface. The device does  not hav e it s own 
power  supply.  The  recording  interval  can be conf igured f rom a minimum of  30 
seconds to a maximum of 1 day. The duration of the rec ordings d epends  on t he 
interval and the number of points configured for each device in configurat ion.  One 
year of  data logging is guaranteed for 2 analog resourc es wit h an int erval of  15 
minutes,  per  conf igured  device.  Selecting  other  resources  c an  af f ect  storage 
perf ormance. 

 

 

CAUTION 

 

This  is  a  class  A  product.  It  can  cause  radio -interf erence  in  residential 
environments. Should this occur, the user should take suitable countermeasures 

 

 

CAUTION 

 

Dixell srl reserves the right to vary the composition of  it s p roducts  without  prior 
notice to the customer, ensuring the identical and unchanged features of the same.  

Содержание DIXELL XWEB5000 PRO

Страница 1: ...XWEB5000 PRO V 1 0 ...

Страница 2: ...1592010820 XWEB5000 PRO STP GB r1 0 25 11 2020 docx XWEB5000 PRO 2 20 ...

Страница 3: ... 300 400 SERIES 12 5 2 2 CONFIGURATION FOR XJA XJP XJM MODELS 12 6 LOCAL CONNECTIVITY 13 7 REMOTE CONNECTIVITY 13 7 1 GENERAL AND MINIMUM REQUIREMENTS 13 7 2 DESKTOP SOFTWARE REQUIREMENTS PC 14 7 3 SOFTWARE MOBILE REQUIREMENTS SMARTPHONE TABLET 14 7 4 CONNECTIVITY WITH CROSS CABLE 15 7 5 INTRANET CONNECTIVITY OR LAN CONNECTION AND VPN 16 7 6 INTERNET CONNECTIVITY ON PUBLIC IP 17 7 7 WIFI CONNECTIV...

Страница 4: ...mage resulting from the use of unsupported devices CAUTION Dixell srl reserves theright to amend this manual without prior notice The latest available version can be downloaded from the internet site CAUTION Immediately after the power failure no new data is recorded all recorded data is kept in non volatile memory The memory is electronic and no data is kept or conveyed to other media such as pap...

Страница 5: ...f 4 July 2012 on Waste Electrical and Electronic Equipment WEEE and to the relevant national implementation regulations we inform you that users of EEE in households there is an obligation not to dispose of WEEE as mixed urban waste and to separate waste collection of WEEE Public or private collection systems required by local laws must be used for disposal It is also possible at the end of its li...

Страница 6: ...he brackets Removable female connectors 2x2ways 2x3ways 1x6ways 4 feet for TABLE mounting 6 Jumpers 1 DVI VGA Converter 1 Installation manual 2 ferrites If one of the following parts is damaged promptly contact your dealer You may also receive a modem or a wifi dongle which will not be included in the same package as a package option When working with a modem connection always check that the type ...

Страница 7: ... of the RTC is 35 ppm the maximum drift of the clock in a year is therefore about 18 minutes Approvals The system consisting of this control and monitoring unit and Dixell temperature meters compliant with the EN13485 standard complies with the EC regulation no 37 2005 and in particular with the EN12830 standard Temperature recorders for the transport and storage and distribution of chilled frozen...

Страница 8: ...erside of the device For rack installation on the other hand use the supplied brackets and screws 3 Connect it to the power mains by the supplied power cord 1 Set the power plug up so that it is easily accessible at all times Note Do not turn the system on 4 Connect the RS485 the relays and digital inputs 2 4 16 14 17 and end and or polarise the line if necessary 3 15 5 Connect any telephone lines...

Страница 9: ...ithout having a screen mouse and keyboard attached For example it is possible to use this initial system installation configuration and then disconnect them definitively if you only intend to set up access from the remote station If you intend to use external peripheral devices always connect them to the unit before turning it on Caution always and only connect the external peripheral devices befo...

Страница 10: ...pay attention in Keep the TTL cable away from any source of electromagnetic disturbance Connect each XJ485 module to the instrument with the TTL cable supplied with the module itself Mark the polarity of output 485 which must be respected when connecting the instruments to the network Below is a list of operating tips to obtain the best result in terms of instrument network reliability RS485 seria...

Страница 11: ... future changes the serial line must reach all the stations where the instruments must be controlled On the same line each controller is normally programmed with its own unique serial address t hrough the Adr parameter Refer to the installation manual of the instrument itself for the access and modification procedure To obtain a simple description of the categories to which they belong divide the ...

Страница 12: ...ation will deteriorate the node in which they are inserted is irrelevant even if it could be convenient to do so on the XWEB checking that the other instruments of the serial network have not already integrated and permanent them 5 2 1 CONFIGURATION FOR XC400 600 800 900 AND XH200 300 400 SERIES These instruments have two serial addresses and must be configured in the same way Refer to the instrum...

Страница 13: ...olution higher than 1024x768 pixels Check your display s instruction manual for supported resolutions 7 REMOTE CONNECTIVITY 7 1 GENERAL AND MINIMUM REQUIREMENTS The user or the installer of XWEB can access its user interface as well as locally with screen keyboard and mouse also through a PC that must beconnected and configured to be able to communicate with the XWEB network The XWEB Ethernet port...

Страница 14: ...zillaFirefox SUPPORTED 54 All newer computers are capable of meeting these requirements However it is advisable to use the advice of a computer expert to evaluate the computers to be purchased and or already in your possession In the following sections general information on possible network configurations will be provided Right from the start we recommend that you make use of IT experts and or yo...

Страница 15: ...92 168 0 200 XWEB EVO default address The connection procedure is complete when the login page opens up Enter user name and password to start using your XWEB EVO Caution a pre requisite to setting the connection up correctly is that the XWEB EVO address and network interface address on your PC need to have a compatible IP class For example with an XWEB EVO network interface configured with 192 168...

Страница 16: ...e for your PC any software and credentials if you want to use a VPN network for access Before connecting the XWEB to the network check that the IP address you wish to use for the XWEB is actually free and therefore usable You could perform a PING to that address and if at least one reply is received at the PING the address must be changed as it is already used Example Before connecting the XWEB to...

Страница 17: ...ifically requested from your ISP Internet Service Provider Tell your ISP that you want to install a webserver this will help them recognize your needs and provideyou with an adequate connection It is highly recommended to obtainall the details of the supply contract for the management of any future connectionproblems Connection to the internet is possible in the presence of a router Its configurat...

Страница 18: ...e XWEB access point XWEB is normally supplied preconfigured in this mode so that the user can search with his PC smartphone tablet to an XWEB PRO SSID network The default password is dixellxwebpro i Connection of XWEB to existing Wi Fi network XWEB can be connected via Wi Fi to a Wifi AccessPoint already present on thesite In this case you need to temporarily access the XWEB interface with another...

Страница 19: ...68 0 14 E mail Address ___________________________ example myXWEB001 company com Modem ___________________________ Telephone number ___________________________ 10 TRADEMARKS Consider It Solved and Intelligent Store are trademarks and Emerson Climate Technologies and the Emerson Climate Technologies logo are service marks and trademarks of Emerson Electric Co Windows and Internet Explorer are regis...

Страница 20: ...__________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ _________________________________________...

Отзывы: