background image

Upgrade kit instructions

P/N 3-9000-784, Rev DA

July 2019

Daniel

 Ultrasonic 3410 Series Electronics

Содержание Daniel Ultrasonic 3410 Series

Страница 1: ...Upgrade kit instructions P N 3 9000 784 Rev DA July 2019 Daniel Ultrasonic 3410 Series Electronics ...

Страница 2: ...2 ...

Страница 3: ...0 971 4 8865465 Daniel Measurement and Control Inc Headquarters 11100 Brittmoore Park Drive Houston TX 77041 USA http www emerson com Email Customer Service DanielCST Support Emerson com Customer Support Daniel TechnicalSupport Emerson com Field Lifecycle Services Tech Service Emerson com Asia Pacific danielap support emerson com Europe danielEMA cst emerson com Return Material Authorization RMA A...

Страница 4: ...lt in death or serious injury WARNING Warning indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Caution indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Notice is used to address safety messages or practices not related to personal injury Important Important is a statement the user needs to know ...

Страница 5: ...rts and work procedures specified in this manual Product owners Purchasers Use the correct product for the environment and pressures present See technical data or product specifications for limitations If you are unsure discuss your needs with your Daniel representative Inform and train all personnel in the proper installation operation and maintenance of this product To ensure safe and proper per...

Страница 6: ...ot feel comfortable following the instructions contact your Daniel representative for clarification or assistance Install this product as specified in the INSTALLATION section of this manual per applicable local and national codes Follow all instructions during the installation operation and maintenance of this product Connect the product to the appropriate pressure and electrical sources when and...

Страница 7: ...BILITY FOR PROPER SELECTION USE AND MAINTENANCE OF ANY DANIEL PRODUCT REMAINS SOLELY WITH THE PURCHASER AND END USER TO THE BEST OF DANIEL S KNOWLEDGE THE INFORMATION HEREIN IS COMPLETE AND ACCURATE DANIEL MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND IN NO EVENT SHALL DANIEL BE LIAB...

Страница 8: ... storage or handling or any other cause not the fault of Daniel are not covered by this limited warranty and shall be at Buyer s expense Daniel shall not be obligated to pay any costs or charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by Daniel All costs of dismantling reinstallation and freight and the time and expenses of Daniel s personnel and rep...

Страница 9: ...using RS 232 Serial 48 6 3 Write the converted configuration file to the meter 52 6 4 Configure the meter using the Field Setup Wizard 56 Appendix A Mark III Wiring I O and switch settings 61 A 1 Mark III RS 232 Full Duplex 63 A 2 Mark III RS 485 Half Duplex 64 A 3 Mark III Discrete output switch settings 65 A 4 Mark III RS 232 Full Duplex 66 A 5 Mark III RS 485 Half Duplex 67 A 6 Mark III Series ...

Страница 10: ...Serial communications 84 C 5 Analog input settings 86 C 6 Analog output settings 86 C 7 Digital Input 86 C 8 External power source connection and fuse 87 Appendix D 3410 Series engineering drawings 89 Contents Upgrade kit instructions July 2019 P N 3 9000 784 x 3410 Series Electronics Upgrade kit instructions ...

Страница 11: ...Part I Plan Upgrade kit instructions Plan P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 11 ...

Страница 12: ...Plan Upgrade kit instructions July 2019 P N 3 9000 784 12 3410 Series Electronics Upgrade kit instructions ...

Страница 13: ...ve all the components necessary to perform the retrofit before taking the meter out of service Important If retrofitting from Mark II electronics to 3410 Series electronics complete Sections 3 and 4 in the Daniel Ultrasonic Mark III Upgrade Kit Instructions P N 3 9000 746 to determine the communications and output settings of the Mark II electronics Use those settings and the instructions in this ...

Страница 14: ...Introduction Upgrade kit instructions July 2019 P N 3 9000 784 14 3410 Series Electronics Upgrade kit instructions ...

Страница 15: ...e 7 16 socket F Allen wrench size 6mm Daniel P N 2 4 9200 501 included in Retrofit kit G Crescent wrench for cable glands and electrical conduit Daniel MeterLink is required to communicate with the meter electronics access information and collect the configuration in the meter and then convert and download the configuration into the new 3410 Series electronics Always use the latest version of Dani...

Страница 16: ...Before you begin Upgrade kit instructions July 2019 P N 3 9000 784 16 3410 Series Electronics Upgrade kit instructions ...

Страница 17: ...f important set up data 3 through 8 provide more detailed instructions on obtaining the required information with respect to the communications set up of the Mark III electronics however if these settings are already known these steps can be skipped Step 8 is for Frequency and Diagnostic outputs For reference the known values should be entered in the Summary Table of Communication Output Settings ...

Страница 18: ... wiring terminations and the settings of various switches on the boards that comprise the electronics 6 Power down the electronics CAUTION EQUIPMENT DAMAGE Remove power from the meter electronics Failure to remove power from the meter electronics may result in damage to the equipment 7 Remove the end caps from the upper electronics housing of the meter to access the electronic circuit boards See F...

Страница 19: ...from the upper electronics enclosure Figure 3 3 3400 Electronics Assembly board layout Upgrade kit instructions Before removing the Mark III Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 19 ...

Страница 20: ...mitter electronics enclosure L Power supply M I S Barrier board N Standoffs O Backplane board P O ring Q End cap and security screw R O ring S Acquisition cable and roll pin T Acquisition Module assembly U Base enclosure V Cable glands W Gasket base enclosure X Acquisition cable clamp Y Acquisition Module Before removing the Mark III Electronics Upgrade kit instructions July 2019 P N 3 9000 784 20...

Страница 21: ...Field Connection Board wire terminations and or switch settings of the CPU board and Option Board if installed This information will be used to configure the new 3410 Series electronics later in this procedure Figure 3 5 Mark III CPU Board showing switch settings Upgrade kit instructions Before removing the Mark III Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructi...

Страница 22: ... Mark III CPU Board with I S Barrier Board piggy backed on CPU Board Before removing the Mark III Electronics Upgrade kit instructions July 2019 P N 3 9000 784 22 3410 Series Electronics Upgrade kit instructions ...

Страница 23: ... label the wires to make it easier to connect the 3410 Series electronics 2 Remove any conduit and wiring attached to all six conduit ports 3 Remove any ground wire attached to the ground lug on the outside of the upper electronics housing At this point there should be no wires connected to the upper electronics housing Figure 4 1 Ground wire removed 4 Use the 6mm Allen wrench supplied with kit to...

Страница 24: ... electronics b Loosen the two screws on the ends of the Acquisition cable connector and disconnect it from the Acquisition module c Set the upper electronics housing aside once the housing is removed Figure 4 3 Remove the Acquisition cable 6 Remove all the screws that hold the transducer wires in the terminal blocks that attach the transducers to the Acquisition module Removing Mark III Electronic...

Страница 25: ...Remove the RTV with a flat blade screwdriver or utility knife around the perimeter of the recessed opening and the RTV eases the removal of the sealant a Use the 7 16 socket wrench to remove the four mounting bolts Figure 4 4 Remove old RTV 10 Remove the base enclosure from the meter body 11 If RTV silicone adhesive sealant was used to seal the base enclosure to the meter body remove the adhesive ...

Страница 26: ...Removing Mark III Electronics Upgrade kit instructions July 2019 P N 3 9000 784 26 3410 Series Electronics Upgrade kit instructions ...

Страница 27: ...Part II Install Upgrade kit instructions Install P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 27 ...

Страница 28: ...Install Upgrade kit instructions July 2019 P N 3 9000 784 28 3410 Series Electronics Upgrade kit instructions ...

Страница 29: ...Unscrew the remaining two mounting screws from the acquisition module in the base enclosure and remove the acquisition board 4 Place an insulating gasket on the meter body where the electronics will be mounted see gasket in Figure 3 4 5 Place the base enclosure on top of the meter body on top of the insulating gasket Note that the transducer port openings on the base enclosure are labeled with tra...

Страница 30: ...base enclosure wells with RTV adhesive sealant around and over the four bolts This will ensure a water tight seal Any excess sealant can be removed by using a scraper to leave the sealant flush with the top of the well Excess sealant will adhere to the acquisition board when it is installed and make future removal of the board difficult Installing the 3410 Series Electronics Upgrade kit instructio...

Страница 31: ... board in the base enclosure and secure it with the two screws as shown for now Figure 5 5 Acquisition Module attachment screws Upgrade kit instructions Installing the 3410 Series Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 31 ...

Страница 32: ...able glands installation 10 Judge the proper length and cut off the excess 11 Strip the outer insulation outer shield and inner insulation using a utility knife Verify that insulation of individual wires was not cut while removing outer layers Strip each wire 0 28 Installing the 3410 Series Electronics Upgrade kit instructions July 2019 P N 3 9000 784 32 3410 Series Electronics Upgrade kit instruc...

Страница 33: ...sducer cables to the correct length with allowance for the wiring terminations and connector placement 16 Ensure that the contacts clamp on the bare wires and not on the wire insulation when the wires are being terminated on the connector a Leave the connector plugged into the Acquisition board while terminating the individual wires b Tighten the connector screws on the either end of the connector...

Страница 34: ...and C1 D1 and B1 A2 and C2 D2 and B2 Install one cable tie at three inches from the base enclosure and another about the point where the cables start to bend and separate out to their respective port Installing the 3410 Series Electronics Upgrade kit instructions July 2019 P N 3 9000 784 34 3410 Series Electronics Upgrade kit instructions ...

Страница 35: ...e and secure the cable connector by tightening the two screws 19 Install the cable clamp on the Acquisition cable and secure it with the final mounting screw for the Acquisition module Upgrade kit instructions Installing the 3410 Series Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 35 ...

Страница 36: ...per enclosure is properly seated Position the upper enclosure housing so that it is in the desired orientation for reattaching the electrical conduit 22 Install the 3410 meter upper enclosure on the base enclosure once the transducers are wired correctly 23 Install the two screws with the 6 mm Allen wrench to secure the upper enclosure to the base enclosure Installing the 3410 Series Electronics U...

Страница 37: ...ure to base enclosure 24 Remove the end cap next to the conduit entries from the upper enclosure Figure 5 15 shows the layout of the 3410 electronics Upgrade kit instructions Installing the 3410 Series Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 37 ...

Страница 38: ...odule D 3410 Series Transmitter electronics enclosure E I S Barrier Module F Power supply G Backplane H Optional Local Display Module I End cap Installing the 3410 Series Electronics Upgrade kit instructions July 2019 P N 3 9000 784 38 3410 Series Electronics Upgrade kit instructions ...

Страница 39: ...ency Digital Output 3 Configured to output Digital Output 1A Drive Mode Open Collector Digital Output 1A is configured for Validity status If the settings above are not consistent with those used in your meter then these parameters can be changed using Daniel MeterLink software to reconfigure the communication ports and output ports later in this procedure Appendix C of this document contains addi...

Страница 40: ...ver Set the WRITE PROT switch to the OFF position to allow configuration parameters to be written to the meter Only enable the DHCP server if the meter is not connected to a network that may have a DHCP server already running The DHCP server is designed for use when a PC connects directly to the meter and requires the meter to assign the PC an IP address 26 Wire all of the electrical connections I...

Страница 41: ...e 5 17 Install wiring terminal block connectors to the CPU Module Upgrade kit instructions Installing the 3410 Series Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 41 ...

Страница 42: ... upper terminal block and switches C CPU Module D 24 VDC loop power E Optional RS 232 I O Module F 10 4 36 VDC power G Fuse H Optional RS 485 I O Module I Ethernet terminal block J Chassis ground Installing the 3410 Series Electronics Upgrade kit instructions July 2019 P N 3 9000 784 42 3410 Series Electronics Upgrade kit instructions ...

Страница 43: ...ver G Fuse H Guide plate blanking cover I Guide plate blanking cover All of the terminations in the 3410 Series electronics are removable terminal blocks Removing the terminal blocks from the modules before terminating wires to them makes wiring easier Appendix C of this document also includes wiring tables and Upgrade kit instructions Installing the 3410 Series Electronics P N 3 9000 784 July 201...

Страница 44: ...he end caps removed unless you are in a non hazardous or explosive free environment Failure to comply could result in death serious injury and possible equipment damage 29 Apply the sealing compound to the conduit seal fittings and allow to set in accordance with manufacturer specifications 30 Apply electrical power to the system and verify the field connections are working correctly 31 Do not ins...

Страница 45: ...Part III Operate Upgrade kit instructions Operate P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 45 ...

Страница 46: ...Operate Upgrade kit instructions July 2019 P N 3 9000 784 46 3410 Series Electronics Upgrade kit instructions ...

Страница 47: ...ion 1 10 or later Ethernet LAN adapter Configured to automatically obtain IP address via DHCP Desired 3400 Series 3410 Series meter s communication configuration parameters IP address Serial communication parameters such as baud rate and Modbus ID if desired 6 1 2 Ethernet initial connection steps Procedure 1 Power up the 3410 Series meter and wait two minutes for the meter to startup 2 Ensure tha...

Страница 48: ...rial 6 2 1 Communications settings and Field Setup Wizard RS 232 Serial initial connection material checklist The following materials and information are required Ultrasonic serial cable Daniel P N 3 2500 401 Personal computer PC with Daniel MeterLink software version 1 10 or later Desired 34003410 meter s communication configuration parameters IP address if desired Serial communication parameters...

Страница 49: ...Wire colors R X Red T X White C O M Black 3 Start Daniel MeterLink on the PC and create a new Meter Directory record with the following parameters Upgrade kit instructions Configure the 3410 Series Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 49 ...

Страница 50: ...ect box and uncheck the Modem and Ethernet boxes d Set the Direct connection properties for Baud Rate of 19200 and Comms Address Modbus ID of 32 Configure the 3410 Series Electronics Upgrade kit instructions July 2019 P N 3 9000 784 50 3410 Series Electronics Upgrade kit instructions ...

Страница 51: ...he meter Meter Communications Settings Procedure 1 Use the Meter Communications Settings menu path to access the Communications dialog This dialog displays the communications parameters for the 3410 Series electronics and is used to adjust the Baud Rate and Comms Address i e Modbus ID for the serial ports Figure 6 2 Communications Settings dialog Upgrade kit instructions Configure the 3410 Series ...

Страница 52: ...ation file to the meter Important If the Mark III electronics contained keys the user needs to ensure the same keys are enabled in the 3410 electronics prior to writing the convereted configuration Otherwise some configuration points may not be able to be written Configure the 3410 Series Electronics Upgrade kit instructions July 2019 P N 3 9000 784 52 3410 Series Electronics Upgrade kit instructi...

Страница 53: ...isplays Figure 6 4 Edit Compare configuration dialog a Select the final 3400 configuration file created in Step 2 of Section 3 of this document i e Meter Name MKIII Final Config 3 4 2005 10 15 02 AM cfg b Click Open The file opens and you returned to the Edit Compare Configuration dialog Figure 6 5 Open configuration file dialog Upgrade kit instructions Configure the 3410 Series Electronics P N 3 ...

Страница 54: ...etting using the Field Setup Wizard Current Outputs dialog A reminder dialog prompts you to set this parameter Figure 6 7 Hart parameter settings For Gas ultrasonic meters the HART Secondary Variable options are Uncorrected flow rate Corrected flow rate Average flow velocity Average sound velocity Energy flow rate Mass flow rate Configure the 3410 Series Electronics Upgrade kit instructions July 2...

Страница 55: ...s with no errors f Save the 3400 Series electronics configuration file to your PC g With the converted configuration still displayed from the Edit Compare Configuration dialog click the Meter radio button located next to the Compare button see Figure 6 8 h Compare the file to verify that this saved configuration matches the meter configuration If an error occurs go back to the beginning of the 2 a...

Страница 56: ... pressure meter connections and meter outputs b In the Meter name field insert a name for the meter this name displays on Daniel MeterLink main window and the Maintenance logs and Reports files c Ensure the 3410 Series Electronics digital outputs are configured appropriately The 3410 Series Electronics also supports and may be configured for the AGA8 Detailed Method Configure the 3410 Series Elect...

Страница 57: ...he Frequency and Digital Output Sources parameters from the Field Setup Wizard Frequency Digital Outputs Sources Page Upgrade kit instructions Configure the 3410 Series Electronics P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 57 ...

Страница 58: ...1A DO1A FO1B DO1B Frequency or Digital Outputs FODO 2 source selections FO1A DO1A FO1B DO1B FO2A DO2A FO2B DO2B Frequency or Digital Outputs FODO 3 source selections FO1A DO1A FO1B DO1B FO2A DO2A FO2B DO2B Mode options Open Collector requires external excitation supply voltage and pull up resistor TTL internally powered by the meter 0 5 VDC signal Channel B Phase options Lag forward Lead reverse P...

Страница 59: ... out of phase with Phase A Bidirectional output reports flow on Phase A only in the forward direction and on Phase B only in the reverse direction Maximum frequency for the frequency outputs 1000 Hz 5000Hz 3 If changes were made in the Field Setup Wizard choose to save the configuration when Daniel MeterLink prompts you after the changes are written to the meter Click Finish in the Field Setup Wiz...

Страница 60: ...Configure the 3410 Series Electronics Upgrade kit instructions July 2019 P N 3 9000 784 60 3410 Series Electronics Upgrade kit instructions ...

Страница 61: ...gs in this appendix to configure the 3410 Series electronics parameters Figure A 1 Mark III Field Connection Board Switches and Connectors Upgrade kit instructions Mark III Wiring I O and switch settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 61 ...

Страница 62: ...ote The switch positions shown in the sketches of the switch banks are the factory default positions Mark III Wiring I O and switch settings Upgrade kit instructions July 2019 P N 3 9000 784 62 3410 Series Electronics Upgrade kit instructions ...

Страница 63: ...RS 232 Full Duplex Figure A 3 Port A settings Figure A 4 Port B settings Upgrade kit instructions Mark III Wiring I O and switch settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 63 ...

Страница 64: ...gure A 5 Port A settings Factory default switch settings for Port A Figure A 6 Port B settings Mark III Wiring I O and switch settings Upgrade kit instructions July 2019 P N 3 9000 784 64 3410 Series Electronics Upgrade kit instructions ...

Страница 65: ...ngs Figure A 7 Group 1 Frequency and digital outputs Figure A 8 Group 2 Frequency and digital outputs Upgrade kit instructions Mark III Wiring I O and switch settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 65 ...

Страница 66: ...tion board if installed A 4 Mark III RS 232 Full Duplex Figure A 10 Port C settings Mark III Wiring I O and switch settings Upgrade kit instructions July 2019 P N 3 9000 784 66 3410 Series Electronics Upgrade kit instructions ...

Страница 67: ...s A 6 Mark III Series 100 option board if installed Figure A 12 Analog output 1 Figure A 13 Analog input 1 Temperature Upgrade kit instructions Mark III Wiring I O and switch settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 67 ...

Страница 68: ... Series 100 Plus HART option board if installed A 7 Mark III RS 232 Full Duplex Figure A 16 Port C settings Mark III Wiring I O and switch settings Upgrade kit instructions July 2019 P N 3 9000 784 68 3410 Series Electronics Upgrade kit instructions ...

Страница 69: ...Mark III Series 100 plus HART option board if installed Figure A 18 Analog output 1 Figure A 19 Analog output 2 HART capable Upgrade kit instructions Mark III Wiring I O and switch settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 69 ...

Страница 70: ...A 20 Analog input 1 Temperature Figure A 21 Analog input 2 Pressure Mark III Wiring I O and switch settings Upgrade kit instructions July 2019 P N 3 9000 784 70 3410 Series Electronics Upgrade kit instructions ...

Страница 71: ...l Serial Port B Not Used if J7 not used RS 232 if S4 is set to RS232 RS 485 Half Duplex if S4 is set to RS482 and S5 2 is set to Half RS 485 Full Duplex if S4 is set to RS 485 and S5 2 is set to Full Serial Port C Not Used if J16 not used RS 232 if S10 is set to RS232 RS 485 Half Duplex if S10 is set to RS 485 Digital Output 1A Not Used if J4 2 not used TTL if S8 1 is set to TTL Open Collector if ...

Страница 72: ...set to SINK Analog Input 2 Not Used if J12 3 not used Source if S13 is set to SRC Sink if S13 is set to SINK Analog Output 1 Not Used if J11 not used Source if S14 is set to SRC Sink if S14 is set to SINK Analog Output 2 HART Capable Not Used if J10 not used Source if S15 is set to SRC Sink if S15 is set to SINK Enter the results of the 3400 Summary Table of Communications output settings in the t...

Страница 73: ...put 2 HART Capable 1 Port B and C are not available for 3410 Series electronics in default configuration Port B is available for 3410 Series electronics with Optional I O RS 232 RS 485 or Expansion I O Modules installed Port C is also available for the Retrofit enclosure with two Optional I O Modules installed Upgrade kit instructions Communication Output settings P N 3 9000 784 July 2019 3410 Ser...

Страница 74: ...Communication Output settings Upgrade kit instructions July 2019 P N 3 9000 784 74 3410 Series Electronics Upgrade kit instructions ...

Страница 75: ...Series Ultrasonic Gas Flow Meter Installation Manual P N 3 9000 759 for more wiring details Figure C 1 3410 Upper electronics with Optional I O Modules Upgrade kit instructions 3410 Communication and Output settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 75 ...

Страница 76: ...ects configuration and firmware overwrites To write configuration changes or download firmware to the meter change the switch to the OFF position Switch position ON default setting enables write protection of the configuration and firmware OFF enables writing configuration changes or downloading firmware 3410 Communication and Output settings Upgrade kit instructions July 2019 P N 3 9000 784 76 34...

Страница 77: ... 232 serves as an override during meter commissioning to establish communications and in the event the user cannot communicate with the meter due to an inadvertent communication configuration change The override period is for two minutes Supports auto detected ASCII Start bit 1 Data Bit 7 Parity Odd Even Stop Bit 1 RTU Start Bit 1 Data Bit 8 Parity none Stop Bit 1 Modbus protocols RS 232 Baud rate...

Страница 78: ...reen when transmitting data LINK ETH1Link user Ethernet connection Solid green Optional RS 232 Module wiring Use the table in MISSING LINK HERE to wire the Optional RS 232 module Figure C 3 Optional RS 232 Module wiring Optional RS 485 Module wiring Use the table in MISSING LINK HERE to wire the Optional RS 485 module 3410 Communication and Output settings Upgrade kit instructions July 2019 P N 3 ...

Страница 79: ...ependent off network single host After configuration of the Daniel 3410 Series Gas Ultrasonic Flow Meter the DHCP option must be turned off if used on a LAN WAN NOTICE RESTRICTED ETHERNET AND SERIAL CONNECTIVITY USAGE Failure to restrict Ethernet and communication access to the Daniel 3410 Series Gas Ultrasonic Flow Meter can result in among other things unauthorized access system corruption and o...

Страница 80: ...ble Daniel P N 1 360 01 596 to connect the PC to the meter A DIN 41612 48 pin connector is the interface from the CPU Module to the Backplane male end located on the back of the Backplane Board C 3 Input and output connections The Daniel 3410 Series Ultrasonic Flow Meter provides the Analog inputs for pressure and temperature Analog output 2 and frequency and digital outputs on the CPU Module lowe...

Страница 81: ...put 3 FODO 3 E Analog Output 2 4 20mA output F Analog Output 2 4 20mA output G Analog In Temperature H Analog In Temperature I Analog In Pressure J Analog In Pressure Possible configurations for Frequency and Digital Outputs are shown in the following figure Upgrade kit instructions 3410 Communication and Output settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 81 ...

Страница 82: ... CPU Module lower terminal block share a common ground and have 50V isolation This allows an output to be connected to a different flow computer The outputs are opto isolated from the CPU Module and have a withstand voltage of at least 500V rms dielectric 3410 Communication and Output settings Upgrade kit instructions July 2019 P N 3 9000 784 82 3410 Series Electronics Upgrade kit instructions ...

Страница 83: ... ground Type 2 A FODO1 and Digital input1 shared common ground Group1 B FODO2 and FODO3 shared common ground Group2 Upgrade kit instructions 3410 Communication and Output settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 83 ...

Страница 84: ...he BLACK wire goes to COM see Table 3 5 for Port A wiring RS 485 2 wire connection on Port A uses TX and TX on the CPU Module and has a ground wire When Belden wire No 9940 or equivalent is used the maximum cable length for RS 232 communications at 9600 bps is 88 3 meters 250 ft and the maximum cable length for RS 485 communication at 57600 bps is 600 meters 1970 ft Port A supports a special overr...

Страница 85: ... 247 Auto detects TCP IP and ASCII or RTU Protocol ASCII Protocol Start Bits 1 Data Bits 7 2 Parity odd or even 1 Stop Bits 1 3 Baud Rates 1200 2400 9600 19200 38400 57600 115000 bps RTU Protocol Start Bits 1 Data Bits 8 4 Parity none Stop Bits 1 5 Baud Rates 1200 2400 9600 19200 38400 57600 115000 bps Ethernet Preferred port for diagnostic communication via Daniel MeterLink 10 Mbps 100 Mbps Modbu...

Страница 86: ...c Flow Meter provides two 4 20 mA analog output signals that are software configurable for either sink or source current Refer to the System Wiring Diagram in Appendix D Full HART functionality is provided so that any commercially available HART transmitter which meets the specifications of the HART Communications Foundation can be connected to a Daniel3410 Series Ultrasonic Flow Meter C 7 Digital...

Страница 87: ...meter analog outputs temperature transmitter or pressure transmitter devices The current is limited to 88mA Figure C 10 CPU Module power source connections A 24V Loop power B Power in connector Main power source C 2 Amp fuse used for main power input Upgrade kit instructions 3410 Communication and Output settings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 87 ...

Страница 88: ...3410 Communication and Output settings Upgrade kit instructions July 2019 P N 3 9000 784 88 3410 Series Electronics Upgrade kit instructions ...

Страница 89: ...ngineering drawings DMC 005324 3410 Series Ultrasonic Meter System Wiring Diagram Upgrade kit instructions 3410 Series engineering drawings P N 3 9000 784 July 2019 3410 Series Electronics Upgrade kit instructions 89 ...

Страница 90: ......

Страница 91: ......

Страница 92: ......

Страница 93: ......

Страница 94: ...ica Dubai UAE T 971 4 811 8100 Asia Pacific Singapore T 65 6777 8211 2019 Daniel Measurement and Control Inc All rights reserved Unauthorized duplication in whole or part is prohibited Printed in the USA Daniel Measurement and Control Inc Daniel is an Emerson Automation Solutions business unit The Daniel name and logo are trademarks of Daniel Industries Inc The Emerson logo is a trademark and serv...