background image

7

emersonfans.com

Please contact 1-800-654-3545 for further assistance

ETL Model No.: CF790

3. Ceiling Fan Assembly

(Continued)

4.5" 
DOWNROD

CEILING 
COVER

Figure 6

3.7

Place the ceiling cover over the downrod. Be sure both
the  ceiling  cover  and  the  coupling  cover  are  oriented
correctly (Figure 6).

4.5" DOWNROD

HANGER BALL

PIN

SETSCREW

Figure 7

3.8

NOTE: Only use the hanger ball supplied with this

ceiling fan.

Route  the  three  80”  motor  leads  through  the  hanger
ball. 

Reinstall  the  hanger  ball  (Figure  7)  on  the  downrod  as
follows:

Position the hanger ball pin through the two holes in the
downrod and align the ball so the pin is captured in the
groove in the top of the hanger ball. 

Pull  the  hanger  ball  up  tight  against  the  pin  and
securely tighten the setscrew in the hanger ball.

NOTE: A loose setscrew could create fan wobble.

HANGER BALL/ 

DOWNROD 

ASSEMBLY

6 to 9

INCHES

Figure 8

3.9

The fan comes with black, blue and white leads that are
80-inches long.

Before  installing  the  fan,  measure  up  approximately
6  to  9-inches  above  top  of  hanger  ball/downrod
assembly (Figure 8).

Cut  off  excess  leads  and  strip  back  insulation  1/2-inch
from end of leads.

Содержание CROFTON CF790BS00

Страница 1: ...Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com CROFTON 58 Ceiling Fan Owner s Manual CF790BS00 Brushed Steel with Walnut Dark Mahogany Blades CF790SW00 Satin White with Satin White Maple Blades CF790VNB00 Venetian Bronze with Walnut Dark Mahogany Blades CF790VS00 Vintage Steel with Walnut Riverwash Blades Model Numbers Español página 29 Français page...

Страница 2: ...trician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electrical shock this fan should only be used with fan speed control Model No UC7067RA manufactured by Rhine Electric Co Ltd WARNING This product is designed to use only those ...

Страница 3: ...rom being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding 1 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper styrofoam with the top of the motor facing up The upper styrofoam serves as a holder for the fan during the first stages of assembly PACKAGE CONTENTS 5 10 7 9 8 11 4 1 2 3 6 Part Description Quantity A ...

Страница 4: ...ire Size A W G Up to 50 ft 14 50 100 ft 12 4 ETL Model No CF790 2 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes co...

Страница 5: ...uit breaker or fuse box before attempting to install the ceiling fan mounting plate on the outlet box 3 Ceiling Fan Assembly 3 2 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 3 8 NOTE Do not loosen the scre...

Страница 6: ...he downrod to make sure the clevis pin is properly installed 4 5 DOWNROD MOTOR COUPLING RETIGHTEN SETSCREW RETIGHTEN SETSCREW Figure 4 4 5 DOWNROD COUPLING COVER GROMMET Figure 5 3 6 Make sure the grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing Figure 5 It is critical that the clevis pin in the motor coupling is p...

Страница 7: ...l the hanger ball Figure 7 on the downrod as follows Position the hanger ball pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball NOTE A loose setscrew could create fan wobble HANGER BALL DOWNROD ASSEMBLY 6 to 9 INCHES Figure ...

Страница 8: ...hment screws from the motor before installation of blade assemblies Figure 10 Discard the spacers and spacer screws BLADE FLANGES 5 10 32 x 1 4 WASHER HEAD SCREWS 3 REVERSIBLE FAN BLADES 5 Figure 11 3 12 Your ceiling fan is supplied with one set of 5 reversible fan blades Choose the finish to compliment your decor and mount the blades to the blade flanges as follows Mount blade flanges to ceiling ...

Страница 9: ...all five blade flange assemblies are secured to the motor hub proceed to tightening all 1 4 20 x 1 2 round head screws with lockwashers at this time SWITCH HOUSING ADAPTER REMOVE ONE 8 32 x 5 16 ROUND HEAD SCREW LOOSEN TWO 8 32 x 5 16 ROUND HEAD SCREWS 3 15 Remove one 8 32 x 5 16 round head screw from the motor housing reserve for later use Loosen the other two screws to assemble the switch housin...

Страница 10: ...G ADAPTER REMOVE THREE 8 32 x 5 16 FLAT HEAD SCREWS Figure 14 3 18 Match and engage the color coded connector of the switch housing assembly with the color coded motor connector Figure 15 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly SWITCH HOUSING ASSEMBLY CONNECTOR FAN MOTOR CONNECT...

Страница 11: ...lied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 17 WARNING 4 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure...

Страница 12: ...T BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY HANGER BRACKET HANGER BALL HANGER BALL GROOVE ANTI ROTATION TAB Figure 19 4 How to Hang Your Ceiling Fan Continued 4 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 19 Be sure the groove in the ball is engaged...

Страница 13: ...ith this product by Emerson Electric Co could result in personal injury or property damage WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical sh...

Страница 14: ...nnector supplied Figure 23 Securely connect the fan motor black wire to the receiver red TO MOTOR L wire using wire connector supplied Figure 23 Securely connect the fan motor blue wire to the receiver blue FOR LIGHT wire using wire connector supplied Figure 23 OUTLET BOX ANTENNE WIRE SLIDE RECEIVER INTO HANGER BRACKET TUCK ALL WIRES INTO OUTLET BOX Figure 24 5 5 After connections have been made t...

Страница 15: ... COVER LOCKWASHERS 2 KNURLED KNOBS 2 Figure 27 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING 5 8 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 27 5 9 Secure the ceiling cover in place by sliding lo...

Страница 16: ...switches are factory set in the ON up position Change the switch settings as follows NOTE Do not duplicate the code of an existing control of an installed ceiling fan within 100 feet 6 3 Slide the five switch levers in the SW405 wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 6 4 The sixth switch marked ON and ...

Страница 17: ...er NOTE Make all wiring connections using wire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 7 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan SW405 wall control into the outlet box 7 2 Remove faceplat...

Страница 18: ...l fan installation is completed 7 7 The SW405 wall control is supplied with a white ivory and almond color switch covers Choose the finish that best suits your needs and snap the cover onto the SW405 wall control Figure 30 7 8 Install decorator wall plate using the two screws provided with wall plate Leave the SW405 wall control in OFF mode until fan installation is completed Figure 30 SW405 FAN L...

Страница 19: ...Disconnect wires from existing controls only Do not attempt to disconnect any wires not already connected to existing controls 7 11 Before installing the SW405 wall control place the SW405 wall control in OFF mode by pushing ON OFF switch to the OFF position 7 12 Install a SW405 wall control in the wall box containing the hot wire first Connect the black wire of the SW405 wall control to the hot w...

Страница 20: ... the wall box containing the load wire Connect the black wire of the SW405 wall control to the traveler wire s already connected to the black wire in the other wall box Secure with wire connectors supplied 7 17 Connect one black wire of the SW405 wall control to the load black wire and secure with wire connector supplied 7 18 Connect one black wire of the SW405 wall control to both remaining trave...

Страница 21: ...on Within one minute of flipping the switch to ON push and hold the FAN OFF button for 3 to 5 seconds to set the code in the receiver The ceiling fan lights if installed will blink to indicate the SW405 wall control code has been paired with the receiver 8 2 If programming is unsuccessful retry the above instructions after cycling the SW405 wall control ON OFF switch to restart the 1 minute progra...

Страница 22: ...testing the SW405 wall control WARNING HIGH TO LOW BUTTONS ON OFF SWITCH O OFF ON LIGHT BUTTON FAN BUTTON POWER INDICATOR LIGHT OFF ON Figure 33 9 Using Your Ceiling Fan 9 5 Restore electrical power to the outlet box by turning the electricity on at the main fuse box All fans are shipped from the factory with the reversing switch positioned to the left circulate air downward If airflow is desired ...

Страница 23: ... the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particula...

Страница 24: ...12 4 14 15 5 19 18 17 20 8 11 21 6 7 22 PARTS BAG 16 17 18 13 21 23 15 14 20 22 19 9 10 3 13 1 2 OFF ON OFF ON OFF ON OFF ON 24 ETL Model No CF790 13 Repair Parts ...

Страница 25: ...4625 VS 5 Motor Coupler Cover 1 764626 BS 764626 SW 764626 VNB 764626 VS 6 Fan Blade Flanges 5 764630 BS 764630 SW 764630 VNB 764630 VS 7 Fan Blades 5 764634 WA DM 764634 SW MP 764634 WA DM 764634 WA RW 8 Switch Housing Adapter 1 764636 BS 764636 SW 764636 VNB 764636 VS 9 Switch Housing 1 764637 BS 764637 SW 764637 VNB 764637 VS 10 Wiring Harness 1 764638 BL 764638 W 764638 BL 764638 BL 11 Receive...

Страница 26: ...olding flanges to blades are loose 4 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupling is loose 1 Tighten the setscrews securely in the motor or shakes coupling excessively 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball downrod assembly is loose assembly 3 Screws securing fan blade flanges to 3 Check to be sure screws which attach the fan motor are lo...

Страница 27: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Страница 28: ... Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74940000 Form No BP7494 Revision 150610 ETL Model No CF790 Printed in China 06 15 ...

Отзывы: