Temperature Taking Hints and Tips

• 

All body site temperatures are not the same. The 
temperature taken at different sites on the body will vary 
significantly. A forehead (temporal) temperature, for 
example, is usually 0.5°F (0.3°C) to 1.0°F (0.6°C) lower 
than an oral temperature.

• 

Make certain the thermometer is in FOREHEAD MODE.

• 

Non-contact infrared thermometers measure surface 
temperature. Hold the device approximately 1 inch (2-3 
cm) from the center of the forehead to capture just the 
forehead temperature and not the temperature of other 
surrounding objects. 

• 

Always hold the thermometer and the forehead steady 
when taking a reading. Do not move the thermometer 
until you hear the final beep.

• 

The device is designed to be used indoors. Users and the 
thermometer should be in the same ambient temperature 
for at least 10 minutes before taking a reading.

• 

The tested individual should be away from extreme 
temperatures for at least 10 minutes before taking a 
measurement. Recent exposure to hot or cold 
temperatures will impact your reading.

• 

Do not take temperatures with this thermometer near 
places that are very hot, such as fireplaces and stoves.

• 

Remove hair, sweat, oils, cosmetics or dirt from the 
forehead before taking a measurement. Wait at least 10 
minutes after washing the forehead area before taking a 
reading. Remove hats and wait 10 minutes before taking a 
reading. Bangs may cause higher readings.

• 

The tested individual should not drink, eat, or be 
physically active before/while taking the measurement.

PRODUCT FEATURES

Fast reading (approx.1 second)

No probe covers needed

Beeps when reading is complete

Mercury free

Stores 10 readings

Automatic shut-off

Distributed by Cooper-Atkins

Emerson Commercial & Residential Solutions
33 Reeds Gap Road | Middlefield, CT 06455

T

 +800-835-5011 | 

F

 +860-347-5135

www.cooper-atkins.com  |  67-1793 | 0520

Manufactured by JoyTech Healthcare Co., Ltd.

No.365, Wuzhou Road,
Yuhang Economic Development Zone,
311100, Hangzhou, China
T +86-571-81957767

Made in China

• 

Temporal artery temperature changes faster than a 
temperature taken rectally, orally or under the arm. A 
difference of 1°F (.6°C) is normal. Body temperature can 
change throughout the day.

• 

Consistently low temperature readings may be caused by a 
dirty instrument window. Use an alcohol wipe or a cotton 
swab moistened with alcohol (70% isopropyl) to clean the 
instrument window and housing. Gently wipe and let air dry. 
DO NOT use any other cleaning liquids or immerse the 
thermometer in water. Wait 10 minutes after cleaning to 
take a temperature. See manual for complete cleaning 
instructions. 

• 

It is helpful to know each individual’s normal temperature 
when they are well. This is the best way to accurately 
diagnose a fever. To determine normal temperature, take 
multiple readings when healthy. Re-measure with a 
standard digital thermometer for confirmation. This 
thermometer displays an oral equivalent temperature 
reading. Oral readings are approximately 0.9°F (0.5 °C) 
lower than a rectal digital measurement.

• 

When comparing temperature taken with different 
thermometers at different sites, it is important to start with 
the most accurate oral temperature that can be achieved. 
Fast read digital thermometers use a method called “peak 
hold” that is often less accurate than a digital thermometer 
that needs to be held in the mouth for 60 seconds or more. 
It is best to correlate other types of temperature taking to a 
baseline oral temperature taken with accurate oral 
thermometers, (those without the “peak hold” function). 

The contents of this Quick Start Guide are provided by the manufacturer and are not to be construed as warranties or guarantees, express or implied, regarding the products or services described 
herein or their use or applicability. Responsibility for proper selection, use and maintenance of product remains solely with the purchaser and end-user. 

67-1793   Emerson is a trademark of Emerson Electric Co. ©2020. All rights reserved.

Отзывы: