FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
WARNING
!
11. Troubleshooting
Make sure main power is turned OFF.
WARNING
!
Make sure main power is turned OFF.
WARNING
!
21
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF955L
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not start.
1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan. 2. Check line power connections to fan.
3. The remote control transmitter battery needs 3. Check that the remote transmitter battery is in good
replacement. condition; the blue indicator will illuminate when the key
pad buttons are depressed.
4. Fan/Light remote control is OFF. 4. Turn ON Fan/Light remote control.
5. Remote is not programmed. 5. Program the remote and receiver per the Owner’s
Manual instructions.
2. Fan sounds
1. Blades not attached to fan. 1. Attach blades to fan before operating.
noisy.
2. Screws securing fan motor to motor 2. Check to make sure the screws which attach the blades to
hub are loose. the motor are tight.
3. Screws holding blades to motor are loose. 3. Tighten screws securely.
4. Glass globe loose. 4. Tighten the glass globe securely.
5. Hanger bracket and/or ceiling outlet box is not 5. Tighten the hanger bracket screws to the outlet box,
securely fastened. and/or secure outlet box.
3. Fan wobbles
1. Screws securing fan blades to motor are loose. 1. Check to be sure screws which attach the fan blade to the
excessively.
motor are tight.
2. Set screw in motor coupler is loose. 2. Raise coupler cover and tighten the set screw securely.
3. Fan blades out of balance. 3. Interchanging an adjacent (side by-side) blade pair can
redistribute the weight and result in smoother operation.
Or use supplied balancing kit to balance blades.
4. Hanger bracket and/or ceiling outlet box is not 4. Tighten the hanger bracket screws to the outlet box,
securely fastened. and/or secure outlet box.
5. Set screw in hanger ball/downrod assembly is 5. Tighten the set screw in the hanger ball/downrod
loose. assembly.
6. Screws securing fan motor to the motor hub 6. Check to be sure the screws which attach the
are loose. motor to the motor hub are tight.
4. Light fixture will
1. Loose electrical connectors. 1. Shut off the branch circuit electricity at the fuse box or
not illuminate.
breaker panel and check the electrical connectors for
proper installation.
2. The remote control transmitter battery needs 2. Replace the AAA remote batteries.
replacement.
Содержание CF955LBS00