background image

Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not start.

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit breakers.

2. Loose power line connections to the fan, or loose 

2. Check line wire connections to fan and switch switch wire

switch wire connections in the switch housing.

connections in the switch housing.wire connections in the switch
housing.

WARNING:

Make sure main power is turned off.

3. Reversing switch in neutral position.

3. Make sure reversing switch position is all the way to one side.

2. Fan sounds noisy.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Screws securing fan blade flanges to motor 

2. Check to make sure the screws which attach the fan flanges to the 

are loose. 

motor are tight. 

3. Wire connectors inside switch housing rattling.

3. Check to make sure wire connectors in switch housing are not

rattling against each other or against the interior wall of the switch
housing.

WARNING:

Make sure main power is turned off.

4. Motor noise caused by solid-state variable

4. Some fan motors are sensitive to signals from Solid-State variable

speed control.

speed controls. If Solid-State Control is used and motor noise
results choose an alternative control method.

5. Screws holding blades to flanges are loose.

5. Tighten screws securely.

3. Fan wobbles

1. Setscrewin motor coupling is not tightened 

1. Raise coupling cover and tighten setscrew securely.

excessively.

securely.

2. Setscrew in the hanger ball/downrod assembly is 

2. Tighten the setscrew in the hanger ball/downrod assembly.

loose.

3. Screws securing fan blade flanges to motor are loose.

3. Check to be sure screws which attach the fan blade flanges to the 

motor are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat firmly and uniformly to

the surface of the motor. If flanges are seated incorrectly, loosen
the flange screws and retighten according to the procedure in the 
section on "How to Put Your Ceiling Fan Together".

5. Hanger bracket and/or ceiling outlet box is not    

5. Tighten the hanger bracket screws to the outlet box, and/or secure

securely fastened

outlet box. 

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side) blade pair can redistribute

the weight and result in smoother operation.

9

WARNING: 

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER

BEFORE TROUBLE SHOOTING YOUR FAN.

!

!

!

Accessories

1. Ceiling Fan Light Kits (see store or catalog).

2. Ceiling Fan/Light Controls (see store or catalog).
3. Downrod Extension Kits (see store or catalog).

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Electric Co. could result in personal injury
or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

WARNING

!

WARNING

!

U.L. Model No.: CF936

Содержание CF936GBZ00

Страница 1: ...thorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass ...

Страница 2: ...oxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Страница 3: ...completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before pro ceeding 2 Remove the fan assembly from the p...

Страница 4: ... ceiling cover and the coupling cover are both oriented correctly Figure 3 6 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely t...

Страница 5: ... closes properly 13 Remove the three switch housing mounting screws Figure 7 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three mounting screws Figure 8 NOTE Do not pinch wires between the switch housing assembly and t...

Страница 6: ...tric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use...

Страница 7: ...this product by Emerson Electric Co could result in personal injury or property damage WARNING NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 12 Check to see that all connections are tight including ground and that...

Страница 8: ... required and should be avoided to prevent damage to finish Maintenance Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil ing fan Here are a few tips to ensure qual...

Страница 9: ...setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are loose 3 Check to be sure screws which attach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly ...

Страница 10: ...10 4 9 8 5 7 11 12 17 16 1 2 3 10 6 13 19 15 14 13 19 18 Repair Parts U L Model No CF936 ...

Страница 11: ... 6 Ceiling Canopy 762456 GBZ 762456 8 9 Coupling Cover 762463 GBZ 762463 12 12 Wiring Harness 763758 763758 14 Switch Housing 763087 GBZ 763087 PW 16 Flange set of 5 763088 GBZ 763088 PW 17 Blade set of 5 761859 32 761859 30 Owner s Manual BP7382 BP7382 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE F...

Страница 12: ...U L Model No CF936 Part No F40BP73820000 Printed in China 12 08 Form No BP7382 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 ...

Страница 13: ...15 ...

Отзывы: