background image

13

emersonfans.com

Please contact 1-800-654-3545 for further assistance

E.T.L. Model No.: CF773

11. Repair Parts Listing

Before discarding packaging material, be certain all parts have been removed.

HOW TO ORDER REPAIR PARTS

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:

• PART NUMBER

• NAME OF ITEM

• PART DESCRIPTION

• MODEL NUMBER

The model number of your Fan will be found on a label attached to the top housing.

For repair parts, phone 1-800-654-3545.

Model Numbers

Key
No.

Description

CF773BS00

CF773ORB00

CF773SW00

*

Hanger Ball Assembly,

761655-17

761655-32

761655-92

Consisting of:

1

Hanger Bracket

2

Hanger Ball

3

Downrod, 4.5”

*

Parts Bag Containing:

764388-CHRM

764388-BLOX

764388-CHRM

4

Wire Connector (3)

5

Threaded Stud (2)

6

Lockwasher (2)

7

Knurled Knob (2)

8

Pin, Clevis

9

Clip, Hairpin

10

Wood Ball/Chain

11

Screw, 1/4-20 x .5” (11)

12

Screw, #10-32 x .25” (16)

13

Screw, Switch Cup (4)

14

Screw, Switch Adapter (1)

15

Screw, Center Plug (1)

16

Blade Balance Kit

17

Ceiling Canopy

764389-BS

764389-ORB

764389-SW

18

Coupler Cover

764390-BS

764390-ORB

764390-SW

19

Wiring Harness

764391-BLK

764391-BLK

764391-WHT

20

Switch Housing Cover Plate

764291-BS

764291-ORB

764291-SW

21

Switch Housing Assembly

764292-BS

764292-ORB

764292-SW

22

Blade Flange (set of 5)

764294-BS

764294-ORB

764294-SW

23

Fan Blade (set of 5)

764599-DC/DM

764599-DC/WA

764599-CK/MP

Owner's Manual

BP7482

BP7482

BP7482

Содержание CF773BS00

Страница 1: ...EY II 42 Ceiling Fan Owner s Manual Model Numbers CF773BS00 Brushed Steel CF773ORB00 Oil Rubbed Bronze CF773SW00 Satin White Net Weight 18 1 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com ...

Страница 2: ...uctions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied...

Страница 3: ...st If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B C D E I G F H PACKAGE CONTENTS 1 4 3 5 11 7 8 9 6 2 10 Part D...

Страница 4: ...Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall swi...

Страница 5: ...ver over the downrod Be sure that the ceiling cover and the coupler cover are both oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up ...

Страница 6: ...scard the five screws and shipping retainers Figure 6 11 Attach the flange blade assembly to the motor hub using the two 1 4 20 x 5 round head flange screws supplied Make sure the screws are tightened securely Figure 6 12 Repeat this procedure for the other four blade assemblies 13 Remove one of the screws from the switch adapter Retain for future installation Loosen the two remaining screws in th...

Страница 7: ...eeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceilin...

Страница 8: ...personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 10 WA...

Страница 9: ...t wire using wire connector supplied Figure 13 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded stu...

Страница 10: ...n cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING REVERSING SWITCH SPEED CONTROL SWITCH PULL CHAIN IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive ...

Страница 11: ...ate variable 4 Some fan motors are sensitive to signals from Solid State speed control variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupler are not 1 Raise coupler cover and tighten setscrews securely excessively tightened ...

Страница 12: ...12 E T L Model No CF773 11 Repair Parts 1 5 2 3 6 17 7 18 9 8 12 13 22 23 21 19 10 15 4 16 20 11 14 ...

Страница 13: ...ing of 1 Hanger Bracket 2 Hanger Ball 3 Downrod 4 5 Parts Bag Containing 764388 CHRM 764388 BLOX 764388 CHRM 4 Wire Connector 3 5 Threaded Stud 2 6 Lockwasher 2 7 Knurled Knob 2 8 Pin Clevis 9 Clip Hairpin 10 Wood Ball Chain 11 Screw 1 4 20 x 5 11 12 Screw 10 32 x 25 16 13 Screw Switch Cup 4 14 Screw Switch Adapter 1 15 Screw Center Plug 1 16 Blade Balance Kit 17 Ceiling Canopy 764389 BS 764389 OR...

Страница 14: ...14 E T L Model No CF773 Notes ...

Страница 15: ...is limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returni...

Страница 16: ...Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74820000 Form No BP7482 Revision 131125 E T L Model No CF773 Printed in China 11 13 ...

Отзывы: