background image

1. Securely attach the hanger bracket to the outlet box

using the two screws supplied with the outlet box
(Figure 5).

AT LEAST

7'

CEILING

FLOOR

How to Hang Your Ceiling Fan

Figure 4

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 5

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

Figure 6

2.Carefully lift the fan from the foam pad and seat the

hanger ball/downrod assembly on the hanger
bracket that was just attached to the outlet box
(Figure 6). Be sure the groove in the ball engages
with the tab on the hanger bracket (Figure 5).

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

How to Wire Your Ceiling Fan

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1.Connect the green grounding lead from the hanger

ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this may
be a bare wire or wire with green colored insulation).

GROUND
WIRE

WIRE
CONNECTORS (3)

GREEN WIRE
(GROUND) 
FROM FAN

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY
(HOT)

BLACK AND BLUE
FAN WIRES

Figure 7

NOTE: CEILING COVER
OMITTED FOR CLARITY.

5

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 4).

WARNING

!

The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.

WARNING

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician in in doubt.

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.

WARNING

!

Содержание CF742PFOB

Страница 1: ...to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered Th...

Страница 2: ...upporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan b...

Страница 3: ... blades c One ceiling cover d Five blade flanges e One hanger ball downrod assembly f One hanger bracket g One loose parts bag containing 1 Sixteen 3 16 24 x 1 2 screws 2 Eleven 1 4 20 x 7 16 blade flange screws 3 One pull chain pendant 4 One pull chain coupling 5 Three wire connectors 6 One clevis pin 7 One hairpin clip 8 Two threaded studs 9 Two lockwashers 10 Two knurled knobs NOTE Place the pa...

Страница 4: ...IS PIN HAIRPIN CLIP CLEVIS PIN HANGER BALL DOWNROD ASSEMBLY SETSCREW SETSCREW Figure 1 Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this ...

Страница 5: ... BLACK AND BLUE FAN WIRES Figure 7 NOTE CEILING COVER OMITTED FOR CLARITY 5 The fan must be hung with at least 7 of clearance from floor to blades Figure 4 WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws...

Страница 6: ...e black and blue leads on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 8 CEILING COVER THREADED STUD KNURLED KNOB LOCKWASHERS 2 Figure 8 1 Restore electrical power to the outlet box by turning the elect...

Страница 7: ... fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 6 Fan blades out of balan...

Страница 8: ...Knob 2 Pull Chain Pendant Pull Chain Coupling Owners Manual BP7178 5 BP7178 5 6 6 6 4 5 6 3 6 2 1 1 1 6 6 6 7 6 6 Part No F40BP71780005 Form No BP7178 5 Printed in Taiwan 09 99 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER T...