background image

9

18. Screw in two 60-watt (maximum)

candelabra bulbs in the light fitter
sockets (Figure 12). Bulbs not
supplied.

19. Place the lower glass into the light

fitter, aligning the three flat areas on
the lower glass flange with the three
tabs on the light fitter (Figure 13).
Then turn the lower glass clockwise
until the glass stops turning.

20. Your ceiling fan is now installed and

wired to be controlled by your SW101
Fan/Light Wall Control.

FLAT AREAS (3)

LOWER 
GLASS

TABS (3)

LIGHT FITTER

Figure 13

Setting Operating

Frequency of Wall

Control and Receiver

(Figure 14)

Your wall control and receiver have code
switches which must be set in one of 16
possible code combinations. The four
levers (numbered 1, 2, 3, and 4) on the
switches are factory-set in the ON (up)
position. Change the switch settings as
follows:

1. Slide the four switch levers in the wall

control to your choice of ON (up) or
down positions. Use a ball-point pen or
small screwdriver and slide the levers
firmly up or down.

2. In the receiver, slide the four switch

levers to the same positions as set in
the wall control. Make sure the levers
on both switches are in the same
positions, otherwise the fan will not
operate.

Figure 14

WALL CONTROL
LEVERS

ON

1

2

3

4

RECEIVER
SWITCH LEVERS

ON

1

2

3

4

CODE
SWITCH

ANTENNA WIRE

1    2    3    4

ON

RECEIVER

CODE
SWITCH

WALL 
CONTROL

LIGHT 
FITTER

TIGHTEN 
THREE PAN 
HEAD 
SCREWS

60-WATT 
(MAXIMUM) 
CANDELABRA 
BULBS (2)

INSTALL PAN HEAD SCREW 
WITH LOCKWASHER

PENDANT

COUPLING

REVERSING 
SWITCH PULL 
CHAIN

CLIP

CHAIN

HOLE

Figure 12

17. Slip the reversing switch chain

through the pendant (supplied), then
secure the pendant by snapping the
coupling onto the end of the chain
(Figure 12). Hook the chain in the clip
as shown in Figure 12 insert.

NOTE: Make sure that the lockwashers
are positioned between the screw head
and the light fitter.

BP7315 Florissant  3/7/06  8:42 AM  Page 9

Содержание CF730

Страница 1: ...ized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Elect...

Страница 2: ...se the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 5 Follow the recommended instructions for the proper...

Страница 3: ...page 5 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NO...

Страница 4: ... remote control receiver mounted under the fan housing This system allows you to regulate your ceiling fan speed and light intensity NOTE An optional Emerson Electric SR100 Remote Control may also be used to control your ceiling fan Ceiling Fan Procedures NOTE Place the parts from the loose parts bags in a small container to keep them from being lost Turning off wall switch is not sufficient To av...

Страница 5: ...MOTOR BRACKET FAN MOTOR ASSEMBLY Figure 4 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for ...

Страница 6: ...lack AC IN L wire d Securely connect the fan motor white wire to the receiver white TO MOTOR N wire e Securely connect the fan motor black wire to the receiver red TO MOTOR L wire f Securely connect the fan motor blue wire to the receiver blue FOR LIGHT wire SUPPLY WHITE NEUTRAL AND RECEIVER WHITE WIRES SUPPLY BLACK HOT AND RECEIVER BLACK WIRES GREEN WIRE FROM MOTOR BRACKET RECEIVER AND MOTOR BLUE...

Страница 7: ... and connectors up into the outlet box 7 Pivot the motor assembly on the hook so that the three threaded studs on the mounting plate protrude through the three holes in the motor bracket Figure 7 8 Install and securely tighten three 1 4 20 locknuts and flat washers nuts and washers supplied onto the threaded studs Figure 7 then try to shake the motor bracket to ensure that the assembly is tight MO...

Страница 8: ... fan wobble This completes the blade installation 15 Pass the reversing switch pull chain through the hole in the light fitter Figure 12 Position the three keyhole slots in the light fitter over the three pan head screws in the switch housing flange and turn the light fitter clockwise 13 Remove and retain the pan head screw with lockwasher from the recessed portion of the switch housing flange Fig...

Страница 9: ...vers in the wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 In the receiver slide the four switch levers to the same positions as set in the wall control Make sure the levers on both switches are in the same positions otherwise the fan will not operate Figure 14 WALL CONTROL LEVERS ON 1 2 3 4 RECEIVER SWITCH ...

Страница 10: ...cuit breaker or remove fuse 2 At all wall box locations remove faceplates and screws from existing controls Pull controls out from wall boxes and determine which wall box contains the hot lead and which wall box contains the load wire Also identify traveler wires which are common to both wall boxes Disconnect wires from existing controls only Do not attempt to disconnect any wires not already conn...

Страница 11: ...CK GROUND NEUTRAL EMERSON EMERSON HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF REMOTE CONTROL RECEIVER LOCATED UNDER THE FAN HOUSING Figure 17 HOT BLK FAN LIGHT WALL CONTROL BLK TRAVELER WIRES BLK BLK BLACK LOAD BLACK LOAD TRAVELER WIRES HOT BLK EXISTING WALL CONTROL EMERSON EMERSON HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF Figure 18 STANDARD WIRING FOR EXI...

Страница 12: ...HT button The light brightness will continue to increase then decrease while the button is held down When the light is at the desired brightness release the button 5 To turn the housing lights on and off press and release the LIGHT button The light will turn on at the light level previously set see step 4 6 If airflow is desired in the opposite direction turn the fan off and wait for the blades to...

Страница 13: ...tial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be dete...

Страница 14: ...tain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 14 BP7315 Florissant 3 7 06 8 42 AM Page 14 ...

Страница 15: ...63136 WB 763136 BZH 763136 AGW 7 Glass Lower 763144 763144 1 763144 1 Parts Bag Containing 763135 763135 763135 8 Bracket Assembly Receiver 9 Screw Pan Head with Lockwasher M5 x 12mm 5 10 Connector Wire 3 11 Screw Washer Head M5 x 6mm 16 12 Locknut 1 4 20 4 13 Washer Flat 1 4 4 14 Pendant Pull Chain 15 Coupling 16 Screw Pan Head with Lockwasher M6 x 14mm extra flange screw 17 Wall Control Fan Ligh...

Страница 16: ...attach the loose blade flanges to the motor hub are tight 2 Screws holding blades to 2 Tighten screws securely flanges are loose 3 Fan wobbles 1 Screws securing fan blade 1 Check to be sure screws flanges to mounting hub which attach the fan blade are loose flanges to the mounting hub are tight 2 Fan blade flanges not 2 Check to be sure that the seated properly fan blade flanges seat firmly and un...

Отзывы: