background image

19

emersonfans.com

Please contact 1-800-654-3545 for further assistance

U.L. Model No.: 42-CL

Emerson Ceiling Fan Product Limited Warranty

What The Limited Warranty Covers:

This limited warranty is offered by Emerson, a Division of Luminance Brands (“Emerson” or “our” or “we” or “us”) to the original purchaser (“you” or “your”) of a consumer or industrial Emerson 

ceiling fan product including its motor and the other components, and accessories of a consumer or industrial Emerson ceiling fan product sold separately (“Emerson Ceiling Fan Product(s)”) 

against defects in workmanship and materials, subject to the exclusions described below.
What The Limited Warranty Period Of Coverage Is:

All limited warranty periods herein begin on the date of original Emerson Ceiling Fan Product purchased by You. 

This limited warranty covers the Emerson consumer Ceiling Fan Product motor for the lifetime of the original purchaser’s ownership when operated in accordance with Your Emerson Ceiling Fan 

Product Owner’s Manual or other instructions provided by Emerson to You with the Emerson consumer Ceiling Fan Product. 

This limited warranty covers the Emerson industrial Ceiling Fan Product motor for five years from the date of purchase of Your Emerson industrial Ceiling Fan Product (when operated in 

accordance with Your Emerson Ceiling Fan Product Owner’s Manual or other instructions provided by Emerson to You with the Emerson industrial Ceiling Fan Product).

This limited warranty covers the Emerson Ceiling Fan Product LED drivers and LED arrays component or accessory LED drivers and LED arrays for a period of five (5) years. 

All other components of the Emerson Ceiling Fan Product certified as ENERGY STAR® including motor electronics are covered by this limited warranty for a period of three (3) years. 

All other components and accessories of the Emerson Ceiling Fan Product including motor electronics are covered by this limited warranty for a period of one (1) year. 
No Other Express or Implied Warranty Applies:

THE LIMITED WARRANTIES PROVIDED ABOVE ARE THE SOLE AND EXCLUSIVE WARRANTIES PROVIDED BY EMERSON TO YOU FOR YOUR Emerson Ceiling Fan Product, AND 

ARE IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED, WHETHER ARISING BY OPERATION OF LAW OR OTHERWISE, WHETHER OR NOT THE 

PURPOSE HAS BEEN DISCLOSED AND WHETHER OR NOT THE Emerson Ceiling Fan Product HAS BEEN SPECIFICALLY DESIGNED OR MANUFACTURED FOR YOUR USE OR 

PURPOSE. EMERSON HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 

FOR A PARTICULAR PURPOSE. 
How You Can Receive Warranty Service:

You must be the original purchaser and have proof of Your purchase of Emerson Ceiling Fan Product from an authorized Emerson Dealer to obtain Your remedy under this limited warranty. 

You can return Your Emerson Ceiling Fan Product to an authorized Emerson Dealer, or You can call Emerson Customer Service at 1-800-237-6511 to obtain a return authorization and service 

identification tag.  In order for Us to confirm that Your Emerson Ceiling Fan Product is still under warranty, please retain Your receipt or other proof of purchase and have that information readily 

available when returning Your Emerson Ceiling Fan Product to Your place of purchase, or upon calling Emerson Customer Service. If You call Emerson Customer Service, prior to Your call 

please be prepared to provide all model numbers shown on Your Emerson Ceiling Fan Product. Once We have processed your return authorization request, We will provide You with a postage 

paid return label which should be affixed to the Emerson Ceiling Fan Product package You ship. The return label will be sent to the mailing address You provide to Us by phone.
What We Will Do To Correct Problems:

If the defect is covered by this limited warranty, Emerson will repair or replace the applicable Emerson Ceiling Fan Product at no charge to You. If repair of the Emerson Ceiling Fan Product 

is not practical or possible within a reasonable time and no replacement Emerson Ceiling Fan Product can be provided, Emerson will refund You the actual purchase price of Your Emerson 

Ceiling Fan Product. We will ship the repaired or the replacement Emerson Ceiling Fan Product to You at no charge, but You are responsible for all costs of removal and reinstallation of Your 

Emerson Ceiling Fan Product.
What Is Not Covered under the Limited Warranty:

This limited warranty does not extend to and expressly excludes:

•  The glass globes and light bulbs of Your Emerson Ceiling Fan Product,

•  Any costs or fees associated with the labor, including electrician’s fees, required to install, remove, repair or replace a fan or any fan components or accessories.

•  Loss or damage to the Emerson Ceiling Fan Product motor or any Emerson Ceiling Fan Product component or Emerson Ceiling Fan Product accessory caused by normal wear and tear, 

  rather than due to defects in materials or workmanship,

•  Loss or damage resulting from conditions beyond our reasonable control, including without limitation, unforeseeable operating environmental conditions, repairs not made at Our factory or 

  authorized service center, use of parts or accessories not provided to You as part of this warranty by Our factory or authorized service center, mishandling, unreasonable use, misuse, abuse, 

  modifications or other damage caused by You or a third party to your Emerson Ceiling Fan Product while not in Our possession,

•  Loss or damage resulting from improper installation, or other failure to comply with instructions in Your Owner’s Manual including but not limited to Emerson Ceiling Fan Products installed in 

  unintended industrial or residential applications.

•  Emerson Ceiling Fan Product purchases from unauthorized Emerson Dealers.
This limited warranty is deemed null and void upon the occurrence of either of the following events:
•  You as the original purchaser cease to own the Emerson Ceiling Fan Product, or

•  The Emerson Ceiling Fan Product is moved from its original point of installation.

This limited warranty is only valid within the 50 United States, the District of Columbia, and Canada. No other written or oral warranties apply, and no employee, agent, dealer or other person is 

authorized to give any warranties on behalf of Us.
Limitation of Liability:

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE TO YOU UNDER THIS LIMITED WARRANTY. TO THE EXTENT PERMITTED BY LAW, 

IN NO EVENT SHALL EMERSON OR ANY EMERSON AUTHORIZED DEALER BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING 

ANY ECONOMIC LOSS, WHETHER RESULTING FROM NONPERFORMANCE, USE, MISUSE OR INABILITY TO USE THE Emerson Ceiling Fan Product OR FOR THE NEGLIGENCE OF 

EMERSON OR AN EMERSON AUTHORIZED DEALER. EMERSON SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT, REGARDLESS 

OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR OTHERWISE), 

SHALL EMERSON’S OR ANY EMERSON AUTHORIZED AGENT’S LIABILITY TO YOU OR ANY INDIVIDUAL USING THE Emerson Ceiling Fan Product EXCEED THE PRICE PAID BY THE 

ORIGINAL OWNER FOR THE Emerson Ceiling Fan Product. The term “consequential damages” shall include, but not be limited to, loss of anticipated profits, business interruption, loss of use 

or revenue, cost of capital or loss or damage to property or equipment. 
Dispute Resolution:

In the event of any dispute INCLUDING, BUT NOT LIMITED TO, BREACH OF CONTRACT, BREACH OF WARRANTY, CLAIMS BASED IN TORT, NEGLIGENCE, PRODUCT LIABILITY, 

FRAUD, MARKETING, STATE OR FEDERAL REGULATIONS, ANY CLAIMS REGARDING THE ENFORCEABILITY OF THIS LIMITED WARRANTY, AND THE WAIVER OF CLASS ACTION 

TRIALS between You and Emerson, either party may choose to resolve the dispute by binding arbitration, as described below, instead of in court. THIS MEANS IF EITHER YOU OR EMERSON 

CHOOSE BINDING ARBITRATION, NEITHER PARTY SHALL HAVE THE RIGHT TO LITIGATE SUCH CLAIM IN COURT OR HAVE A JURY TRIAL. DISCOVERY AND APPEAL RIGHTS ARE 

LIMITED IN BINDING ARBITRATION. You and Emerson agree that the proper venue if Arbitration is not so chosen by You or Emerson of all actions arising in connection herewith shall be only 

in the state of Missouri and the parties agree to such jurisdiction. 
CLASS ACTION WAIVER: BINDING ARBITRATION MUST BE ON AN INDIVIDUAL BASIS. THIS MEANS NEITHER YOU NOR EMERSON MAY JOIN OR CONSOLIDATE CLAIMS IN 

ARBITRATION BY OR AGAINST OTHERS, OR LITIGATE IN COURT OR ARBITRATE ANY CLAIMS AS A REPRESENTATIVE OR MEMBER OF A CLASS OR IN A PRIVATE ATTORNEY 

GENERAL CAPACITY.
ADMINISTRATION OF ARBITRATION: The binding arbitration must be administered by the American Arbitration Association (“AAA”) in accordance with its Commercial Arbitration Rules and/

or Supplementary Procedures for Consumer-Related Disputes (including proceedings to mitigate costs of travel). This binding arbitration is governed by the Federal Arbitration Act (“FAA”) 

(9 USC §1, et. seq.) and will govern the interpretation and enforcement. The binding arbitration shall be held at a location determined by AAA or at such other location as mutually agreed. 

In addition to the terms stated above, the following will apply to the binding arbitration: (1) the arbitrator, and not any federal, state, or local court or agency, will have exclusive authority 

to resolve any dispute relating to the interpretation applicability, enforceability or formation of this agreement including any claim that all or any part of this agreement is void or voidable; 

(2) the arbitrator shall apply Missouri law consistent with the FAA.
How State and Provincial Law Relates To The Warranty:

Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to You. This limited warranty gives 

you specific legal rights, and You may also have other rights which vary from state to state or province to province.

Содержание CF702ORB05

Страница 1: ...IONAL 29 Ceiling Fan Owner s Manual READ AND SAVE THESE INSTRUCTIONS Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 Net Weight 11 2 Lbs NORTHWIND Model Numbers CF702ORB05 Oil Rubbed Bronze CF702WW05 Appliance White ...

Страница 2: ...nd use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 Follow the recommended instructions for the proper m...

Страница 3: ...n a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding D A B C G F E PACKAGE CONTENTS 10 1 2 3 4 5 8 9 7 6 1 2 Remove the Fan Motor Assembly from the protective plastic bag Place all carton contents on a protective surface Place the Fan Motor Assembly into the upper styrofoam with the top of the Moto...

Страница 4: ...ossible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or a...

Страница 5: ...Hanger Ball until the Ball falls freely down the Downrod Figure 1 Remove the Pin from the 3 5 Downrod then remove the Hanger Ball Figure 1 Retain the Pin and Hanger Ball for reinstallation in Step 3 8 NOTE Do not loosen the Screw that attaches the Green Ground Wire to the Hanger Ball 3 5 DOWNROD THREE 42 MOTOR LEADS UNTWISTED Figure 2 3 2 Separate untwist and unkink the Three 42 Motor Wires Route ...

Страница 6: ...ugh the holes in the Motor Coupler It is critical that the Clevis Pin in the Motor Coupler is properly installed and securely tightened 3 5 DOWNROD MOTOR COUPLER RETIGHTEN PHILLIPS HEAD SET SCREWS 2 Figure 5 3 5 While pulling up on the Downrod retighten the Two Phillips Head Set Screws to secure the Downrod in the Motor Coupler Figure 5 NOTE The Set Screws must be properly installed as described a...

Страница 7: ... Figure 7 Pull the Hanger Ball up tight against the Pin and securely retighten the Phillips Head Set Screw in the Hanger Ball Figure 7 A loose Phillips Head Set Screw could create fan wobble CEILING COVER 3 5 DOWNROD Figure 6 3 6 Place the Ceiling Cover over the Downrod Figure 6 Be sure that the Ceiling Cover and the Coupler Cover are both oriented correctly Figure 6 HANGER BALL 6 to 9 INCHES 1 2 ...

Страница 8: ...move the Three Switch Housing Mounting Screws Figure 10 from the Switch Housing Plate Retain the Screws for future use in Step 3 11 NOTE If you are using an Emerson light fixture with your fan Remove the screw plug from the bottom of the switch housing cover and install the light in accordance with the light kit Owner s Manual Make light kit electrical connections to blue and white wires marked Fo...

Страница 9: ...h one Blade Assembly to the Motor Hub securely tightening the Two M5 x 13 mm Captive Screws assembled in the Flange Figure 13 Repeat this procedure for the other Four Blade Assemblies A spare M5 x 13 mm Screw is supplied in parts bag if needed You have now completed the assembly of your new Ceiling Fan You can now proceed with hanging and wiring your Fan 3 12 Mount the Blade Flange to the Fan Blad...

Страница 10: ... a qualified electrician if in doubt WARNING 4 1 Disconnect electrical power to the Branch Circuit at the Circuit Breaker or Fuse Box before attempting to install the Ceiling Fan on the Outlet Box Figure 15 MAIN FUSE BOX Figure 15 FLOOR CEILING AT LEAST 7 Figure 14 4 How to Hang Your Ceiling Fan To reduce the risk of injury install the fan so that the blades are at least 7 ft 2 1m above the floor ...

Страница 11: ... the Outlet Box using the Two Screws supplied with the Outlet Box Figure 16 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET ANTI ROTATION TAB OUTLET BOX Figure 16 4 3 Carefully lift the Fan and seat the Hanger Ball Downrod Assembly on the Hanger Bracket that was just attached to the Outlet Box Figure 17 Be sure the Groove in the Ball is engaged with the Anti Rotation Tab on the Hanger Bracket F...

Страница 12: ...urned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories...

Страница 13: ...ed Figure 20 BLACK BLUE WIRES WHITE WIRES GREEN WIRES Figure 21 5 4 After connections have been made turn Wires upward and carefully push Wires into the Outlet Box with the White and Green Wires on one side of the Outlet Box and position the Black and Blue Wires on the other side of the Outlet Box Figure 21 Check to see that all connections are tight including ground and that no bare wire is visib...

Страница 14: ...gly against the Ceiling and the Hole in the Ceiling Cover is clear of the Downrod 6 1 Screw the Two Threaded Studs supplied into the Tapped Holes in the Hanger Bracket Figure 22 THREADED STUDS 2 Figure 22 WARNING See your local Emerson dealer www emersonfans com or the Emerson Ceiling Fan catalog for these accessories Ceiling Fan Light Kits Ceiling Fan Light Controls Downrod Extension Kits The use...

Страница 15: ... position and turn the Ceiling Fan on again Figure 24 The Fan Blades will turn in the opposite direction and reverse the airflow 8 Using Your Ceiling Fan REVERSE SWITCH SWITCH HOUSING ASSEMBLY 8 2 Cut the 3 Speed Switch Pull Chain to a desired length optional Connect the Wood Pendant supplied to the 3 Speed Switch Pull Chain by sliding the Wooden Pendant small hole first onto the Pull Chain Figure...

Страница 16: ...16 U L Model No 42 CL 9 Repair Parts 15 5 1 2 3 16 17 12 13 PARTS BAG 11 14 4 6 7 6 7 9 8 5 10 18 19 10 11 12 13 9 8 ...

Страница 17: ...ctors 3 5 Threaded Studs 2 6 Lockwashers 2 7 Knurled Knobs 2 8 Clevis Pin 1 9 Hairpin Clip 1 10 Screw M5 x 13 mm 1 11 Screw M5 x 6 mm 16 12 Wood Pendant 1 13 Coupler 1 14 Blade Balance Kit 1 15 Ceiling Cover 1 760169 41 760169 16 Wiring Harness 1 762568 2 762568 17 Switch Housing 1 762575 4 762575 18 Blade Set Set of 5 765166 DC WA 765166 WW BO 19 Flange Set Set of 5 762913 762913 Owner s Manual B...

Страница 18: ...Wire connectors inside switch housing 4 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing 5 Switch housing binding against blade hub 5 Check to make sure that the switch housing does not bind against the blade hub 6 Screws holding blades to flanges are loose 6 Tighten the screws securely 3 Fan wobble...

Страница 19: ...normal wear and tear rather than due to defects in materials or workmanship Loss or damage resulting from conditions beyond our reasonable control including without limitation unforeseeable operating environmental conditions repairs not made at Our factory or authorized service center use of parts or accessories not provided to You as part of this warranty by Our factory or authorized service cent...

Страница 20: ...can be found on the carton and on top of the fan housing stamped in ink on a white label You should record this data above and keep it in a safe place for future use 1 800 654 3545 www emersonfans com Retain this manual for future use Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m Eastern Monday Friday DIVISION OF LUMINANCE BRANDS 1945 S Tubeway Av...

Отзывы: