background image

3. Screw the two threaded studs (supplied) into the

tapped holes in the hanger bracket.

4. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 11).

5. Secure the ceiling cover in place by sliding lockwash-

ers over the threaded studs and installing the two
knurled knobs (supplied). (Figure 11). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling and the hole in the ceiling
cover is clear of the downrod. Your fan is now wired to
be turned on and off from the fan switch.

6.Cut the 3-speed switch pull chain to a desired length

(optional). Connect the wood pendant (supplied) to
the 3-speed switch pull chain by sliding the wooden
pendant (small hole first) onto the pull chain. Attach
the chain coupler to the end of the chain and allow the
wooden pendant to fall down over the coupling.

7

CEILING COVER

THREADED STUD

KNURLED KNOB

LOCKWASHERS (2)

Figure 11

NOTE: If you are using an Emerson light fixture
with your fan, remove the three screws securing
the switch housing cover to the switch housing
and remove the cover. Remove the screw plug
from the bottom of the switch housing cover and
install the light in accordance with the light kit
Owner's Manual.

2.Connect the fan motor white wire to the supply

white (neutral) wire using a wire connector
(supplied) (Figure 10). Connect the fan motor black
wire and blue wire to the supply black (hot) wire
using a wire connector (supplied) (Figure 10). Your
fan is now wired to be turned on and off from the
fan switch. After connections have been made, turn
leads upward and carefully push leads into the out-
let box, with the white and green leads on one side
of the outlet box and the black and blue leads on
the other side of the outlet box.

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

How to Wire Your Ceiling Fan

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1.Connect the green grounding lead from the hanger

ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this may
be a bare wire or wire with green colored insulation).

GROUND
WIRE

WIRE
CONNECTORS (3)

GREEN WIRE
(GROUND) 
FROM FAN

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY
(HOT)

BLACK AND BLUE
FAN WIRES

Figure 10

NOTE: CEILING COVER
OMITTED FOR CLARITY.

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.

WARNING

!

Содержание CF654AW00

Страница 1: ...BP73360000 Form No BP7336 U L Model No CF653 READ AND SAVE THESE INSTRUCTIONS Model No CF654AW00 CF654OB00 CF654ORB00 CF654WB00 CF654WW00 WET LOCATION Net Weight 18 7 Lbs 52 Ceiling Fan Owner s Manual ENERGY STAR ...

Страница 2: ... Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot...

Страница 3: ...ll steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer to section on proper method of wiring your fan page 7 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licensed electrician WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 ...

Страница 4: ...ening faces upward Figure 3 5 Reinstall the hanger ball on the downrod as follows Figure 4 Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose ...

Страница 5: ...hanging and the electrical wiring of your fan Electrical Requirements 5 BLADE FLANGE FAN BLADE M5 x 6 WASHER HEAD BLADE SCREW 3 RIB LINE THIS SIDE UP Figure 5 SWITCH HOUSING MOTOR HUB M6 x 14 FLANGE SCREWS WITH LOCKWASHERS 2 Figure 6 To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign ob...

Страница 6: ...sk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The outlet box and joist must be securely mounted and capable of supporting at least 50 ...

Страница 7: ...re and blue wire to the supply black hot wire using a wire connector supplied Figure 10 Your fan is now wired to be turned on and off from the fan switch After connections have been made turn leads upward and carefully push leads into the out let box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box Check to see that all c...

Страница 8: ...rol device WARNING Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the ...

Страница 9: ...ade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 6 Fan blades out of balance 6 In...

Страница 10: ...ave been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 Repair Parts 10 ...

Страница 11: ...Housing Cover 763117 WW 763117 OB 763117 WB 763117 AW 763117 ORB 6 Capacitor 763123 763123 763123 763123 763123 7 Speed Control Switch 763122 763122 1 763122 1 763122 763122 1 8 Reversing Switch 760360 760360 1 760360 1 760360 760360 1 9 Loose Parts Bag 763118 1 763118 763118 763118 2 763118 Containing Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Screw M5 x 6 Washer Head Blade 16 Screw M6 x 14 Flan...

Страница 12: ...rized service center call 1 800 654 3545 for the address of the nearest authorized ser vice center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...

Отзывы: