How to Put Your Ceiling
Fan Together
1.
Pass the 42" motor leads through the opening in
the ceiling cover. Be sure the cover is oriented
correctly.
2.
Separate, untwist and unkink the three motor
leads. Route the motor leads through the hanger
ball/downrod assembly.
3.
Loosen the two setscrews in the motor coupling.
Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 1). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Be sure to
push the straight leg of the hairpin clip through the
hole near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on
the hanger ball to make sure the clevis pin is
properly installed.
4
HANGER
BALL/DOWNROD
ASSEMBLY
CEILING
COVER
SETSCREW
CLEVIS
PIN
HAIRPIN
CLIP
DECORATIVE
CAP
SETSCREW
MOTOR COUPLING
Figure 1
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.
WARNING
!
4.
While pulling up on the hanger ball, securely
tighten the two setscrews in the motor coupling
(Figure 1).
NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.
5.
The fan comes with blue, black and white leads that
are 42” long. Measure up approximately
6 to 9-inches above top of hanger ball/downrod
assembly. Cut off excess leads and strip back
insulation 1/2-inch from end of leads.
U.L. Model No.: CF701
FAN BLADE
M5 x 6mm WASHER
HEAD BLADE SCREW (3 Per Blade)
BLADE FLANGE
To reduce the risk of personal injury, do not bend the
blade flanges when installing the flanges, balancing
the blades, or cleaning the fan. Do not insert foreign
objects between rotating fan blades.
WARNING
!
NOTE: Take care not to scratch fan housing when
installing blades.
NOTE: Remove and discard the three shipping
spacers and screws from the motor hub.
7.
Turn the fan assembly upside down in preparation
for mounting the fan blade assemblies.
8.
Rotate the motor hub until the flange screw hole is
next to the cutout in the switch housing plate.
Attach the blade assembly to the motor hub using
the two M6 x 12mm flange head screws and
lockwashers (Figure 3). Make sure all screws are
tightened. Repeat this procedure for the other four
blade assemblies.
Figure 2
6.
Mount the blade flanges to fan blades using three
M5 x 6mm washer head blade screws per blade
(Figure 2).
SWITCH HOUSING
PLATE
MOTOR HUB
M6 x 12mm FLANGE HEAD
SCREWS WITH LOCKWASHERS (2
BLADE FLANGE
Figure 3