Emerson BUILDER PLUS CF710AB00 Скачать руководство пользователя страница 3

1. Check to see that you have received the following

parts:

NOTE: If you are uncertain of part description,
refer to exploded view illustration.

a. Fan motor assembly
b. Five fan blades
c. One ceiling cover
d. Five blade flanges
e. One hanger ball/downrod assembly
f. One hanger bracket
g. One switch housing cover
h. Glass shades (3 or 4)
i. One loose parts bag containing:

1. Sixteen M5 x 6 washer 

head blade screws

2. One rubber gasket
3. Two wood pendants
4. Two couplings
5. Three wire connectors
6. One clevis pin
7. One hairpin clip
8. One Phillips round

head flange screw

This Manual Is Designed to Make it as Easy as Possible for You to Assemble,

Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 1/4” blade screwdriver

One wire stripper

Three wire connectors (supplied).

MATERIALS

Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
size:

3

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a
check mark in the box. This will insure that all steps have been completed and will be helpful in finding
your place should you be interrupted.

Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 6). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.

NOTE: Place the parts from the loose parts bags
in a small container to keep them from being lost.
If any parts are missing, contact your local
retailer or catalog outlet for replacement before
proceeding.

2. Remove the fan housing assembly from the

protective plastic bag. Turn the upper styrofoam
pad over and carefully place the fan motor
assembly into the recess in the pad with the top of
the motor facing up.

LOOSE
PARTS
BAG

FAN
BLADES

SWITCH HOUSING
COVER

BLADE
FLANGES

GLASS 
SHADES
(3 or 4)

HANGER
BRACKET

CEILING
COVER

HANGER BALL/
DOWNROD
ASSEMBLY

FAN MOTOR
ASSEMBLY

WARNING

!

WARNING

!

WARNING

!

Содержание BUILDER PLUS CF710AB00

Страница 1: ...THESE INSTRUCTIONS BUILDER PLUS Series Ceiling Fan Owner s Manual Net Weight 19 8 Lbs Net Weight 15 0 Lbs Model No CF711AB00 CF711BS00 CF711WW00 CF711WB00 CF711PB00 CF711CK00 CF711AW00 Model No CF710AB00 CF710WW00 CF710PB00 CF710AW00 CF710BS00 CF711 shown ...

Страница 2: ...porting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan bla...

Страница 3: ... completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if...

Страница 4: ...an is designed to be installed either in the standard manner or in the close to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method I...

Страница 5: ...g If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Hanging The Ceiling Fan Standard Method Using Hanger Ball Downrod 1 Carefully lift the fan assembly and seat the hanger ball in the hanger bracket Figure 7 The tab on the hanger bracket must seat in the groove in the hanger ball NOTE The hanger bracket must be mounted flush with the ceiling in order for t...

Страница 6: ...pounds Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed...

Страница 7: ... of the blade flanges Then mount the blade flanges to the fan blades using three M5 x 6 washer head blade screws per blade Figure 11 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 9 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 9 After connections have been...

Страница 8: ...RE SCREW 3 Figure 14 SCREW 3 SWITCH HOUSING COVER SWITCH HOUSING DISCONNECT TWO WIRES FROM LIGHT FIXTURE AND SECURELY CAP WITH WIRE CONNECTORS Figure 15 CAPTIVE SCREW 2 BLADE FLANGE ALIGNMENT SLOT MOTOR HUB Figure 12 RETAINING CLIP GLASS SHADE SQUEEZE RETAINING CLIPS TOGETHER AND SLIDE ON GLASS SHADE Figure 13 2 Mount one blade assembly to the motor hub by mating the alignment post Figure 11 of th...

Страница 9: ...ng fan blade flanges to motor hub 2 Check to make sure the screws which attach the fan are loose flanges to the motor hub are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid stat...

Страница 10: ...by Emerson Company Use of parts or accessories not authorized by Emerson Company Mishandling improper installation modifications or damage to your ceiling fan while in your possession or Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particula...

Страница 11: ...s Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 ...

Страница 12: ...ound Head 1 17 Rubber Gasket Owner s Manual BP7258 2 BP7258 2 BP7258 2 BP7258 2 BP7258 2 BP7258 2 BP7258 2 Repair Parts Listing Form No BP7258 2 Part No F40BP72580002 Printed in China 07 04 Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Model No Key No Description CF710AB00 CF710WW00 CF710AW00 CF710PB00 CF710BS00 Hanger Pack Assembly 762231 762231 1 762231 2 7...

Отзывы: