Disassembly
Section: 8 Disassembly
This section explains:
•
How to disassemble an actuator safely.
Tip
The instructions of this section can be used for maintenance or reconfiguration like spring
set change or maintenance.
Reference numbers for components refer to the exploded view in section 11.
In case of maintenance, discard all the used soft parts like O-ring seals, guide bands,
wear strips and circlip.
WARNING
Actuator must be isolated pneumatically and electrically before any (dis)assembly starts.
Before mounting or (dis)assembling the actuator consult the relevant sections of this manual.
CAUTION: SPRING FORCE
Spring-return actuators contain springs in a compressed state. Follow these instructions to
release the spring force safely.
The end caps of spring-return actuators sizes 25 to 600 should be free of the spring load
after 10 full turns (crosswise relaxing) of the end cap screws. If there is still spring load on
the end cap, this might indicate a broken spring cartridge. Stop this disassembly procedure
immediately. Continuing might cause the end cap to be “shot” away causing serious injury.
Spring return actuator size 950 to 4000 have long end cap screws to release the spring load
safely.
Refer to Appendix A for instructions to safely remove the spring load before disassembling
the end cap of a spring-return actuator with a broken spring cartridge.
NOTICE
The actuator is designed to be installed, commissioned and maintained using generic tools
like wrenches, Allen keys and screwdrivers.
Refer to the tables in this section or refer to appendix B Tool and Torque tables.
26
September 2017
Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 7
Section 8: Disassembly