October 2015
Service Instructions
124842E Rev. C
4
Section 1: Introduction
Introduction
1�7
Fluid Requirements
1�7�1
For use in the hydraulic power module. The following listed fluids are
recommended fluids only and do not limit the use of other hydraulic fluids
compatible with supplied seals and coatings.
1�7�1�1
Standard temperature service (-20°F to +350°F)/(-28.9°C to +176.6°C)
use Shell Tellus S2 V Grade 32 automatic transmission fluid or an Emerson
approved fluid.
1�7�1�2
High temperature service (0°F to +350°F)/(-17°C to +176.6°C) use
Shell Tellus S2 V Grade 32 automatic transmission fluid or an Emerson
approved fluid.
1�7�1�3
Low temperature service (-50°F to +150°F)/(-45.6°C to 65.6°C) use Mobil
Univis HVI 13 hydraulic fluid or an emerson approved fluid.
1�7�2
For use in the -H hydraulic override module and the M11 manual hydraulic
override system:
CAUTION: ONLY USE CORRECT FLUID
Hydraulic fluid, other than listed in step 1.7.2.1 should not be used in the M11 Override or –H
Hydraulic Override Module without prior written approval of Bettis Product Engineering.
1�7�2�1
All temperature service (20°F to +350°F) / (-28.9°C to +176.6°C) use
Shell Tellus S2 V Grade 32 automatic transmission fluid or an Emerson
approved fluid.
1�8
General Tool Information
1�8�1
Tools: All tools/hexagons are American Standard inch. Large adjustable wrench,
two (2) large screwdrivers, Allen wrench set, set of open/box end wrenches, rubber
or leather mallet, torque wrench (up to 1600 foot pounds/1269 N-m), breaker bar,
and a drive socket set. For recommended tool and wrench sizes refer to Section 6
Tables 6.3 through 6.10.
1�9
Actuator Storage
For applications where the actuator is not put into immediate service it is recommended
that the actuator be cycled with at least once per month. Indoor storage, if available, is
recommended for all actuators. Care should be taken to plug all open ports on actuator
and controls to keep out foreign particles and moisture. Also, actuators should not be
stored in an atmosphere harmful to resilient seals. For extended storage, contact factory.
1�10
Actuator Installation
1�10�1
Since there are many valve and actuator combinations, it is not practical to include
detailed instructions for each type. Mountings are designed to be as simple as
possible to keep guess work out of installation.