background image

www.Fisher.com

Baumann™ 51000 Low Flow Control Valve

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Precautions

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Actuator Removal

3

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Plug and Packing Replacement

4

. . . . . . . . . . . . . . . . .

Valve Disassembly

4

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Valve Reassembly

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions and Weights

9

. . . . . . . . . . . . . . . . . . . . . . .

Figure 1. 51000 NPS 1/2 Control Valve with

Baumann 16 Actuator, and FIELDVUE™ DVC2000

Digital Valve Controller

W9066

Introduction

The Baumann 51000 control valve (figure 1) is optimally designed for demanding low flow control and is a perfect fit

where space is at a premium. This compact package provides the connection integrity of flanged body globe valves,

while being significantly lighter and easier to install.

Scope of Manual

This instruction manual includes installation, maintenance, and parts information for the 51000 control valve and

Baumann 16 actuator.

Do not install, operate, or maintain Baumann 51000 control valves without being fully trained and qualified in valve,

actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is

important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and

warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office

before proceeding.

Instruction Manual

D103365X012

51000 Valve

May 2012

Содержание Baumann 51000 Series

Страница 1: ... connection integrity of flanged body globe valves while being significantly lighter and easier to install Scope of Manual This instruction manual includes installation maintenance and parts information for the 51000 control valve and Baumann 16 actuator Do not install operate or maintain Baumann 51000 control valves without being fully trained and qualified in valve actuator and accessory install...

Страница 2: ...d contact your Emerson Process Management sales office for more complete specifications Provide the product serial numbers shown on the nameplate and all other pertinent information WARNING Personal injury could result from packing leakage Valve packing is tightened before shipment however the packing might require some readjustment to meet specific service conditions Maintenance WARNING Avoid per...

Страница 3: ...ld result in damage to the seating and sealing surfaces of the valve and result in damage to the valve and release of process materials Installation 1 Before installing the valve in the pipeline thoroughly clean the line of all dirt welding chips scale oil or grease and other foreign material 2 Install the valve so the controlled fluid will flow through the valve body in the direction indicated by...

Страница 4: ...ody before valve body disassembly The valve packing box may contain process fluids that are pressurized even when the valve has been removed from the pipeline Process fluids may spray out under pressure when removing the packing hardware or packing rings or when loosening the packing box pipe plug 1 Remove the bonnet hex nuts key 7 and lift the bonnet key 6 off the valve body key 1 which may inclu...

Страница 5: ...ion 5 Place the bonnet key 6 onto the valve body key 1 and secure with the hex nuts key 7 For alloy valve bodies place the bonnet key 6 onto the valve body key 1 then place the bonnet flange key 34 over the bonnet confirm correct orientation then secure with the hex nuts key 7 DO NOT TIGHTEN AT THIS POINT 6 Install the stem guide key 8 and packing kit key 9 on the plug stem key 4 in the proper ord...

Страница 6: ...en corresponding with your Emerson Process Management sales office about this equipment always mention the valve serial number When ordering replacement parts also specify the key number part name and desired material using the following parts tables WARNING Use only genuine Fisherr replacement parts Components that are not supplied by Emerson Process Management should not under any circumstances ...

Страница 7: ...tem 81840 30 1 Hex FLEXLOC Nut 81844 39 1 Diaphragm 011759 001 686 40 1 Diaphragm Plate 81850 1 43 1 Lower Actuator Case 81820 44 1 Upper Actuator Case 81823 45 8 Hex Head Cap Screw 81824 46 8 Hex Nut 81825 50 2 O Ring FKM Fluorocarbon 24080 54 1 Coupling 81830 56 1 Travel Scale 983674 001 250 57 2 Pan Head Machine Screw 81812 62 1 Serial Plate 81891 112 1 Washer 25861 24 113 1 Vent Plug 24147 115...

Страница 8: ...51602 1 51602 51602 1 51602 51602 1 28 Stud 2 51703 51703 51703 32 Plug Stem S A 1 Refer to table 4 33 Plug Guide 1 51206 51206 1 34 Flange Bonnet 1 51304 51304 51304 26 Stem Adapter Baumann 16 Actuator Mounting Kit Part Number MTG51T16 27 Hex Jam Nut 31 Stem Adapter Jam Nut 58 Travel Indicator Disc Table 4 Baumann 51000 Plug Selection Key No Valve Size Plug Cv Part Number ASTM A479 S21800 Anneale...

Страница 9: ...5 R9 24 146 5 75 60 2 38 23 0 91 292 11 48 BAUMANN 16 ACTUATOR WITH FIELDVUE DVC2000 POSITIONER DVC6010 DVC2000 DIGITAL VALVE CONTROLLER 3660 3661 POSITIONER A mm inch Table 5 Dimensions and Weights Valve Body Subassembly VALVE SIZE A MATERIAL APPROXIMATE WEIGHTS mm NPS mm Inch kg lbs 6 35 1 4 55 9 2 20 Stainless Steel 0 64 1 4 N10276 Nickel Alloy 1 0 2 2 12 7 1 2 68 6 2 70 Stainless Steel 0 82 1 ...

Страница 10: ...5X012 51000 Valve May 2012 10 Figure 7 Baumann 16 Actuator Front View E1235 177 6 98 146 5 75 159 46 25 60 2 38 23 0 91 1 2 NPT TA6000 TRANSDUCER A mm inch Figure 8 Baumann 16 Actuator with TA6000 Top View E1236 98 3 86 mm inch ...

Страница 11: ...ights ACTUATOR INSTRUMENT APPROXIMATE WEIGHT kg lbs 16 Actuator without instrument 2 1 4 6 Fisher 3660 3661 Positioner 3 6 8 0 FIELDVUE DVC2000 3 8 8 3 FIELDVUE DVC6010 Aluminum 5 8 12 7 FIELDVUE DVC6010 SST 10 0 22 0 FIELDVUE DVC6010f 5 0 11 0 TA6000 Electropneumatic Transducer 2 5 5 5 ...

Страница 12: ...vailable upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice E 2009 2012 Fisher Controls International LLC All rights reserved Baumann Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co Emerson Process Management Emerson and the Emerson logo a...

Отзывы: